Harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a capacitive voltage transformer

被引:0
|
作者
Zhu, Xiaoxian [1 ]
Peng, Qingjun [2 ]
Zou, Dexu [3 ]
Wang, Shan [2 ]
Wang, Haozhou [4 ]
Zhou, Fangrong [2 ]
Chu, Desheng [2 ,5 ]
机构
[1] China Southern Power Grid Yunnan Power Grid Co Ltd, Chuxiong Power Supply Bur, Chuxiong, Yunnan, Peoples R China
[2] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming, Yunnan, Peoples R China
[3] State Key Lab Power Transmiss Equipment Technol, Chongqing, Peoples R China
[4] Kunming Power Supply Bur Yunnan Power Grid Corp, Kunming, Yunnan, Peoples R China
[5] Beijing Univ Aeronaut & Astronaut, Sch Automat Sci & Elect Engn, Beijing, Peoples R China
关键词
harmonic analysis; synchronisation; transformers; DISTRIBUTION-SYSTEMS; IDENTIFICATION; ERRORS;
D O I
10.1049/elp2.12481
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Harmonic state estimation, which highly depends on accurate synchronised phasors, is a crucial basis for the location, traceability, and governance of harmonics in power systems. However, most existing synchronous phasor measurement units (PMUs) provide power frequency phasors rather than harmonic phasors. In addition, as the dominant voltage signal provider for PMUs in power systems, capacitive voltage transformers (CVTs) have complex frequency responses and cannot be directly used for harmonic measurement. Therefore, accurate harmonic state estimation is difficult to achieve in applications. A method for harmonic voltage phasor reconstruction and harmonic state estimation based on the measurement data of a CVT is proposed. First, the reasons for harmonic voltage measurement errors were analysed. Second, the scattering parameter method was used to measure the wideband voltage transfer characteristics of CVT. Third, a voltage reconstruction method was proposed to improve the measurement accuracy and expand the frequency range of synchronous phasor measurement. Fourth, this method was applied to harmonic state estimation, and the performance of harmonic state estimation before and after voltage reconstruction was quantitatively compared. Results showed that the proposed method can remarkably improve the accuracy of harmonic state estimation. Finally, some factors, such as state observability, complex error disturbances, CVT structure, and harmonic order, influencing the performance of the proposed method were investigated. Results further demonstrated that the method has high accuracy, strong anti-interference, and adaptability, and can provide basic information for harmonic localisation and traceability. The authors focus on the problem wherein the accuracy of harmonic state estimation is affected by the current CVT-based synchronous voltage phase measurement error. Furthermore, it proposes a harmonic voltage phase reconstruction and harmonic state estimation method based on CVT measurement data by considering the CVT wideband transfer characteristics from the voltage phase perspective. image
引用
收藏
页码:1332 / 1346
页数:15
相关论文
共 50 条
  • [1] Harmonic voltage measurement error of the capacitor voltage transformer
    Le, Jian
    Zhang, Hao
    Gao, Chao
    Zhou, Qian
    [J]. PLOS ONE, 2018, 13 (11):
  • [2] Research on Capacitance Voltage Transformer Harmonic Measurement
    Shen, Xin
    Shu, Hong-Chun
    Cao, Min
    [J]. SENSORS AND MATERIALS, 2019, 31 (05) : 1499 - 1512
  • [3] Line voltage phasor reconstruction on capacitive voltage transformers using dynamic phasor approach
    Yu, Chi-Shan
    Chang, Li-Ren
    Chou, Chih-Ju
    [J]. JOURNAL OF THE CHINESE INSTITUTE OF ENGINEERS, 2015, 38 (07) : 821 - 832
  • [4] Harmonic Measurements in a Capacitive Voltage Transformer: Improvement Considering the Transformer's Design Parameters
    De la Hoz, Manuel
    Chacon, Juan
    Alonso Sorensen, Dominique
    Zatika Larrinaga, Urko
    Rioja Baron, Cristina
    [J]. 2021 INTERNATIONAL CONFERENCE ON SMART ENERGY SYSTEMS AND TECHNOLOGIES (SEST), 2021,
  • [5] Stray capacitances calculation and harmonic measurement of capacitor voltage transformer
    Zhu, Tiechao
    Shao, Zhenguo
    Nie, Yixiong
    [J]. INTERNATIONAL JOURNAL OF NUMERICAL MODELLING-ELECTRONIC NETWORKS DEVICES AND FIELDS, 2022, 35 (06)
  • [6] Harmonic Voltage Measurement based on Program Josephson Voltage Standard
    Jia, Zhengsen
    Xu, Xitong
    Wang, Lei
    Zhang, Jiangtao
    Pan, Xianlin
    Shi, Zhaomin
    [J]. 2020 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM), 2020,
  • [7] Measurement Error Estimation for Capacitive Voltage Transformer by Insulation Parameters
    Chen, Bin
    Du, Lin
    Liu, Kun
    Chen, Xianshun
    Zhang, Fuzhou
    Yang, Feng
    [J]. ENERGIES, 2017, 10 (03)
  • [8] Voltage harmonic distortion measurements using capacitive voltage transformers
    Vermeulen, HJ
    Davel, P
    [J]. AFRICON '96 - 1996 IEEE AFRICON : 4TH AFRICON CONFERENCE IN AFRICA, VOLS I & II: ELECTRICAL ENERGY TECHNOLOGY; COMMUNICATION SYSTEMS; HUMAN RESOURCES, 1996, : 1012 - 1017
  • [9] Voltage-based Harmonic Compensation Using MCCF State Estimation
    Krasselt, Peter
    Weck, Sebastian
    Leibfried, Thomas
    [J]. 2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2014, : 284 - 289
  • [10] Harmonic voltage measurement based on capacitive equipment dielectric equivalent model and responding current
    Du, Lin
    Feng, Hui
    Li, Xin
    Shao, Xianjun
    Yang, Zhi
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (10)