Outcomes of press-fit radial head arthroplasty in unconstructable radial head fractures with associated elbow injuries: An average 5-year follow up

被引:0
|
作者
Eyre-Brook, A., I [1 ]
Kankanalu, P. [1 ]
Majkowski, L. [1 ]
Zreik, N. [1 ]
Jones, V [1 ]
Thyagarajan, D. S. [1 ]
Ali, A. A. [1 ]
Booker, S. J. [1 ]
机构
[1] Northern Gen Hosp, Shoulder & Elbow Unit, Sheffield, Yorkshire, England
关键词
Radial head arthroplasty; outcomes; trauma; REVISION SURGERY; REPLACEMENT; PROSTHESIS; CEMENT;
D O I
10.1177/17585732241268904
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aims Unstable and nonreconstructable radial head fractures require radial head arthroplasty (RHA) to restore stability. Multiple implant designs are available with varying survival rates (76 to 97%). There is concern that loosening of the press-fit stems leads to implant failure. We review our outcomes using the Acumed press-fit prosthesis for trauma.Methods Between February 2008 and November 2020, all primary RHA for trauma from a single-centre were reviewed. Primary outcome was implant survivorship. Secondary outcome were clinical, radiographic and patient related outcome measures.Results In total, 96 cases were included. Seven revisions were recorded, all within 24-months of implantation. Kaplan-Meier estimated 10-year survival was 92.1% (95% confidence interval (CI) 84.0-96.1%). Median follow-up time was 5.7 years (Interquartile range (IQR) 3.2-8.5 years). Median Oxford Elbow Score was 43 (IQR 29-46) for and median Mayo Elbow Performance Score was 90 (IQR 72-100). 72% were able to fully-return to pre-injury activities. Radiographic analysis identified osteolysis around radial neck (48%), loosening (32%), valgus stem position (20%), heterotopic ossification (16%) and capitellar erosion (15%). No radiological findings were associated with long-term poor clinical outcomes.Conclusion Our study demonstrates an excellent survival of press-fit RHA of 92.1% at 10-years. No radiographic features on follow-up were associated with poorer patient recorded outcome measures.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Radial head replacement with a bipolar system: an average 10-year follow-up
    Sershon, Robert A.
    Luchetti, Timothy J.
    Cohen, Mark S.
    Wysocki, Robert W.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (02) : E38 - E44
  • [22] Isolated MASON type-III radial head fractures: radial head arthroplasty or open reduction and internal fixation - clinical and radiological outcomes with five to fourteen years of follow up
    Ly, Lyliane
    Druel, Thibault
    Gazarian, Aram
    Walch, Arnaud
    INTERNATIONAL ORTHOPAEDICS, 2025, 49 (03) : 767 - 777
  • [23] Comment on "Isolated MASON type-III radial head fractures: radial head arthroplasty or open reduction and internal fixation - clinical and radiological outcomes with five to fourteen years of follow up"
    Tong, Jian
    Li, Xueting
    INTERNATIONAL ORTHOPAEDICS, 2025, : 1261 - 1262
  • [24] 5-YEAR FOLLOW-UP EVALUATION OF THE NONCEMENTED PRESS-FIT TITANIUM HIP-JOINT ENDOPROSTHESIS
    SERAL, F
    VILLAR, JM
    ESTELLER, A
    VIVAR, FG
    ABAD, I
    GRANDE, MM
    JORDA, E
    ESPINAR, E
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (283) : 49 - 56
  • [25] Stress Shielding around Press-Fit Radial Head Arthroplasty: Proposal for a New Classification System Based on the Analysis of 97 Patients with a Mid-Term Follow-Up and a Review of the Literature
    Giannicola, Giuseppe
    Amura, Andrea
    Prigent, Sebastien
    Zoccali, Carmine
    Sessa, Pasquale
    HEALTHCARE, 2024, 12 (03)
  • [26] Press fit condylar total knee arthroplasty: Radiographic evaluation at a 5-year follow-up
    Sandrucci G.
    Cenna E.
    Favuto M.
    Bistolfi A.
    Crova M.
    Journal of Orthopaedics and Traumatology, 2002, 3 (3) : 157 - 162
  • [27] Radial Head Arthroplasty for Fracture: Implant Survivorship and Outcomes at Mean Follow-Up of 8 Years
    Campbell, Benjamin R.
    Rengifo, Santiago
    Wickes, Catherine B.
    Amer, Kamil M.
    Ilyas, Asif M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (01): : 97e1 - 97e6
  • [28] Press-Fit Condylar total knee arthroplasty - 5- to 9-year follow-up evaluation
    Martin, SD
    McManus, JL
    Scott, RD
    Thornhill, TS
    JOURNAL OF ARTHROPLASTY, 1997, 12 (06): : 603 - 614
  • [29] Monoblock polyethylene radial head prosthesis for the treatment of unreconstructable acute radial head fractures with a minimum 1-year follow-up: A retrospective case series
    Ucpunar, Hanifi
    Camurcu, Yalkin
    Altay, Ridvan
    Duman, Serda
    Cobden, Adem
    Sofu, Hakan
    CURRENT ORTHOPAEDIC PRACTICE, 2020, 31 (02): : 120 - 125
  • [30] Elbow Arthroscopy for the Treatment of Radial Head Fractures: Surgical Technique and 10 Years of Follow Up Results Compared to Open Surgery
    Guerra, Enrico
    Marinelli, Alessandro
    Tortorella, Fabio
    Floter, Michelle Dos Santos
    Ritali, Alice
    Sessa, Andrea
    Carbone, Giuseppe
    Cavallo, Marco
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (04)