Scattering effect for relative blood volume monitoring during hemodialysis

被引:0
|
作者
Zhou, Lianqiao [1 ,2 ]
Li, Qinlan [1 ,2 ]
Wei, Shuang [5 ]
Wang, Shugang [5 ]
Cui, Jingqiang [5 ]
Wang, Guosheng [5 ]
Liu, Chong [2 ,4 ]
Su, Yewang [1 ,2 ,3 ]
机构
[1] Chinese Acad Sci, Inst Mech, State Key Lab Nonlinear Mech, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, Sch Engn Sci, Beijing 100049, Peoples R China
[3] Chinese Acad Sci, Inst Mech, Beijing Key Lab Engn Construct & Mechanobiol, Beijing 100190, Peoples R China
[4] Chinese Acad Sci, State Key Lab High Temp Gas Dynam, Inst Mech, Beijing 100190, Peoples R China
[5] Tuoren Hlth Technol Ind Pk, Tuoren Med Device Res & Dev Inst Co Ltd, Henan Key Lab Med Polymer Mat Technol & Applicat, Changyuan Cty 453000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Hemodialysis; Relative blood volume; Optical principle; Scattering; INTRADIALYTIC HYPOTENSION; DIALYSIS HYPOTENSION; LIGHT-SCATTERING; FUTURE;
D O I
10.1016/j.sna.2024.115736
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The long-term survival rate of hemodialysis patients is limited by hemodialysis-related complications, which are attributed to the inappropriate level of relative blood volume (RBV) after treatment. For the conventional optical monitoring methods, the RBV is usually overestimated, especially when the RBV varies in a wide range. Here, we find that the scattering effect of blood on incident light is the dominant factor of nonlinear measurement errors according to the numerical simulation results. Then a computational model considering both the absorption and scattering effect of blood is proposed and applied to a relative blood volume monitoring system (RBVMS). Finally, the RBVMS is validated in a commercial hemodialysis machine, showing a relatively low measurement error of 6.9 %. This result indicates the potential of the system for RBV monitoring during hemodialysis.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Continuous monitoring of blood volume change steering ultrafiltration during hemodialysis: Patient results.
    Knoflach, A
    Polaschegg, HD
    Binswanger, U
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A1338 - A1338
  • [42] Continuous monitoring of blood volume change steering ultrafiltration during hemodialysis: Patient results.
    Knoflach, A
    Polaschegg, HD
    Binswanger, U
    KIDNEY INTERNATIONAL, 1997, 52 (05) : 1428 - 1428
  • [43] Variability of relative blood volume during haemodialysis
    Krepel, HP
    Nette, RW
    Akçahüseyin, E
    Weimar, W
    Zietse, R
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2000, 15 (05) : 673 - 679
  • [44] Variability of relative blood volume during haemodialysis
    Woods, HF
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2001, 16 (02) : 430 - 431
  • [45] Blood Volume Monitoring to Assist Fluid Management in Hemodialysis Patients
    Silva, Bruno C.
    Moyses, Rosa M. A.
    Elias, Rosilene M.
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2016, 67 (01) : 166 - 168
  • [46] Central blood volume monitoring - New technology for hemodialysis.
    Krivitski, N
    Depner, T
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A1340 - A1340
  • [47] Blood volume monitoring in intermittent hemodialysis for acute renal failure
    Tonelli, M
    Astephen, P
    Andreou, P
    Beed, S
    Lundrigan, P
    Jindal, K
    KIDNEY INTERNATIONAL, 2002, 62 (03) : 1075 - 1080
  • [48] Modeling of Change in Blood Volume and Extracellular Fluid Volume during Hemodialysis
    Zhu, Fansan
    Kappel, Franz
    Leonard, Edward F.
    Kotanko, Peter
    Levin, Nathan W.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1506 - 1509
  • [49] Critical Evaluation of Blood Volume Measurements during Hemodialysis
    Dasselaar, Judith J.
    van der Sande, Frank M.
    Franssen, Casper F. M.
    BLOOD PURIFICATION, 2012, 33 (1-3) : 177 - 182
  • [50] Automatic control of blood volume trends during hemodialysis
    Santoro, A.
    Mancini, E.
    Paolini, F.
    Spongano, M.
    Zucchelli, P.
    ASAIO Journal, 1994, 40 (03)