Highly Integrated Improved Hexagonal CSRR-Based Fluid Sensor for Complex Dielectric Parameter Detection

被引:13
|
作者
Han, Xueyun [1 ]
Peng, Peidong [1 ]
Fu, Chenghao [1 ]
Qiao, Lei [1 ]
Ma, Zhongjun [2 ]
Liu, Ke [1 ]
Zhang, Siyu [1 ]
机构
[1] Henan Normal Univ, Coll Elect & Elect Engn, Xinxiang 453000, Peoples R China
[2] Henan Normal Univ, Coll Environm, Xinxiang 453000, Peoples R China
关键词
Sensors; Resonant frequency; Permittivity; Magnetic liquids; Sensitivity; Substrates; Sensor phenomena and characterization; Complementary split-ring resonator (CSRR); complex permittivity; material characterization; microwave sensor; substrate integrated waveguide (SIW); SPLIT-RING-RESONATOR; MICROWAVE SENSOR; WIRELESS COMMUNICATION; CRACK DETECTION; PLANAR ANTENNA; PERMITTIVITY; SENSITIVITY; WATER;
D O I
10.1109/JSEN.2024.3399454
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
To enable rapid characterization of the complexpermittivity of unknown solutions, we propose a low-cost,compact, and highly integrated microwave microfluidic sen-sor. This sensor, fabricated on an FR4 substrate, employsa substrate-integrated waveguide (SIW) structure combinedwith a complementary split-ring resonator (CSRR). The struc-ture includes a ring of closely spaced metal vias surroundingthe hexagonal CSRR, enhancing the electric field's concen-tration. We optimized the sensor's parameters and developedits equivalent circuit model using ADS software. Interactionwith the sample occurs when a polydimethylsiloxane (PDMS)microfluidic channel, positioned above the sensing structure,contains the liquid sample. This setup alters the sensor's no-load frequency, initially set at 2.46 GHz, impacting the resonant frequency andQ-factor. We introduced a first-ordercharacteristic matrix model to analyze and confirm the sample's properties based on these changes. Our results, witha measurement error of approximately 5%, affirm the accuracy in determining the complex permittivity. The sensor'sdimensions are 44x30x0.8 mm(3), requiring a minimal sample volume of 2.32 mu L and offering a high sensitivity of 0.448%. Its ease of fabrication, capability for rapid noninvasive measurements, and high sensitivity make it an ideal toolfor noninvasive liquid characterization in biological and chemical fields
引用
收藏
页码:20559 / 20570
页数:12
相关论文
共 40 条
  • [21] Integrated SPP-Dielectric Hybrid Coupler Based Sensor For Ultra-thin Layer Detection
    Fan, Boyu
    Liu, Fang
    Wang, Xiaoyan
    Li, Yunxiang
    Huang, Yidong
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [22] Broadband refractive index sensor based on localized surface plasmon for highly sensitive detection of fluid pressure
    Han, Xue
    Tian, Jingkun
    Li, Zongwen
    Wu, Tiange
    Ji, Guangmin
    Li, Shilei
    Xing, Fei
    Zhang, Yonghui
    APPLIED SURFACE SCIENCE, 2022, 587
  • [23] Red emitting fluorescence sensor based on Eu-tungstate complex for the detection of bilirubin in biological fluid
    Shkhair, Ali Ibrahim
    Madanan, Anju S.
    Varghese, Susan
    Abraham, Merin K.
    Indongo, Geneva
    Rajeevan, Greeshma
    Arathy, B. K.
    Abbas, Sara Muneer
    George, Sony
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 329
  • [24] A highly sensitive modified triple split ring metamaterial-based sensor for blood sample detection based on dielectric property alteration
    Rahman, Abdullah Al Mahfazur
    Islam, Mohammad Tariqul
    Kirawanich, Phumin
    Bais, Badariah
    Alsaif, Haitham
    Maash, Abdulwadoud A.
    Hoque, Ahasanul
    Moniruzzaman, Md.
    Islam, Md. Shabiul
    Soliman, Mohamed S.
    APL MATERIALS, 2024, 12 (07):
  • [25] Highly selective detection of Fe3+ and nitro explosives by a bifunctional sensor based on Cd(II) complex
    Zhao, Bo
    Liu, Hao
    Gu, Yanan
    Sun, Qiaozhen
    INORGANIC AND NANO-METAL CHEMISTRY, 2023, 53 (08) : 769 - 775
  • [26] Rapid and accurate detection of phosphate in complex biological fluids based on highly improved antenna sensitization of lanthanide luminescence
    Gao, Hang
    Zhang, Peng
    Guan, Tianyong
    Yang, Yingjie
    Chen, Mingmao
    Wei, Jiaojiao
    Han, Siyuan
    Liu, Yan
    Chen, Xueyuan
    TALANTA, 2021, 231
  • [27] Inkjet-printed phosphorescent Iridium(III) complex based paper sensor for highly selective detection of Hg2+
    Ponram, Marimuthu
    Balijapalli, Umamahesh
    Sambath, Baskaran
    Iyer, Sathiyanarayanan Kulathu
    Kakaraparthi, Kranthiraja
    Thota, Giridhar
    Bakthavachalam, Venkatachalapathy
    Cingaram, Ravichandran
    Sung-Ho, Jin
    Sundaramurthy, Karthikeyan Natesan
    DYES AND PIGMENTS, 2019, 163 : 176 - 182
  • [28] Low-Fouling Surface Plasmon Resonance Sensor for Highly Sensitive Detection of MicroRNA in a Complex Matrix Based on the DNA Tetrahedron
    Nie, Wenyan
    Wang, Qing
    Zou, Liyuan
    Zheng, Yan
    Liu, Xiaofeng
    Yang, Xiaohai
    Wang, Kemin
    ANALYTICAL CHEMISTRY, 2018, 90 (21) : 12584 - 12591
  • [29] A highly sensitive and selective on-off fluorescent sensor based on a complex of polySchiff-Fe2+ for Cr(vi) detection in an aqueous medium
    Li, Zhiying
    Li, Congshu
    Yan, Huiyun
    RSC ADVANCES, 2021, 11 (15) : 8963 - 8969
  • [30] Molecularly Imprinted Electrochemical Sensor Based on α-Cyclodextrin Inclusion Complex and MXene Modification for Highly Sensitive and Selective Detection of Alkylresorcinols in Whole Wheat Foods
    Wen, Yangyang
    Wang, Mengyao
    Gong, Weiwei
    Wang, Hailin
    Fan, Haoran
    Li, Hongyan
    Wang, Jing
    Sun, Baoguo
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2024, 72 (18) : 10655 - 10664