A rapid and facile immunoassay for C-reactive protein using PDMS-based digital magnetofluidics

被引:0
|
作者
Ngernpradab, Pakakan [1 ]
Wongravee, Kanet [2 ,3 ]
Srisa-Art, Monpichar [1 ]
机构
[1] Chulalongkorn Univ, Fac Sci, Electrochem & Opt Spect Ctr Excellence, Dept Chem, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Sci, Dept Chem, Sensor Res Unit SRU, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Sci, Res Network NANOTEC CU Adv Struct & Funct Nanomat, Bangkok 10330, Thailand
关键词
FLOW IMMUNOASSAY; ASSAY; NANOPARTICLES; IMMUNOSENSOR; SYSTEM;
D O I
10.1016/j.aca.2024.343044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: C-reactive protein has been reported as a biomarker of inflammation caused by acute injury, infection or tissue damage and also a prediction marker of cardiovascular diseases. Commonly, the gold standard for the detection of CRP is enzyme-linked immunosorbent assays (ELISAs). Normally, traditional immunoassays in multiwell plates typically suffer from prolonged assay time due to slow mass transport controlled by diffusion. Herein, a PDMS based magnetofluidic approach has been applied for a rapid and facile immunoassay using a sandwich enzyme-linked immunosorbent assay (ELISA) for the analysis of CRP. Results: Due to the superhydrophobic PDMS, droplets of reagent and sample solutions were obtained when pipetting all solutions onto the PDMS substrate. These droplets were individually controlled by an external magnet to perform the assays. Magnetic beads immobilized with a capture antibody were not only used for immunomagnetic separation (IMS) of the captured CRP from the sample matrix, but also used as a carrier for droplet movement on the magnetofluidic device, expediting the immunoassay procedure, especially washing steps. The immunoassay of CRP was successfully performed within 1 h with a limit of detection of 0.015 mg L-1 in the concentration range of 0.1-10 mg L-1.-1 . The recovery percentages of CRP spiked in human serum were found in the range of 90-114 % with %RSD of less than 5 %, indicating acceptable accuracy and precision. Significance: By individually controlling the droplet movement using an external magnet, all steps of immunoassays were simply and rapidly performed. In addition, the microfluidic format allows for small volumes of reagents and samples and rapid assay kinetics. Therefore, the proposed magnetofluidic approach has shown its potential of becoming a rapid, facile and cost-effective method to perform traditional immunoassays in a variety of applications. In addition, the proposed approach is also particularly well-suited for analyses/reactions with multiple steps.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] One-step immunoassay of C-reactive protein using droplet microfluidics
    Tang, Matthew Y. H.
    Shum, Ho Cheung
    LAB ON A CHIP, 2016, 16 (22) : 4359 - 4365
  • [22] A Rapid and Specific C-Reactive Protein Immunoassay Driven by an Electrophoresis System Based on Protein Enrichment in a 3D Filter
    Zhang, Fangfang
    Ma, Junjie
    Watanabe, Junji
    Liu, Huiyu
    Shen, Heyun
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2017, 9 (04) : 425 - 432
  • [23] Conventional diagnosis of C-reactive protein in serum using latex piezoelectric immunoassay
    Aizawa, H
    Kurosawa, S
    Ogawa, K
    Yoshimoto, M
    Miyake, J
    Tanaka, H
    SENSORS AND ACTUATORS B-CHEMICAL, 2001, 76 (1-3) : 173 - 176
  • [24] IMMUNOASSAY OF C-REACTIVE PROTEIN USING THE HITACHI-705E ANALYZER
    HARMOINEN, A
    JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY, 1985, 23 (01): : 45 - 46
  • [25] Surface plasmon resonance-based immunoassay for human C-reactive protein
    Vashist, S. K.
    Schneider, E. M.
    Luong, J. H. T.
    ANALYST, 2015, 140 (13) : 4445 - 4452
  • [26] Visualization of immunoassay based on a spot test and its application to C-reactive protein
    Morita, K
    Kaneko, E
    Tsuda, T
    Yoshimura, H
    CHEMISTRY LETTERS, 2005, 34 (05) : 704 - 705
  • [27] Detection of c-reactive protein based on a magnetic immunoassay by using functional magnetic and fluorescent nanoparticles in microplates
    Yang, S. F.
    Gao, B. Z.
    Tsai, H. Y.
    Fuh, C. Bor
    ANALYST, 2014, 139 (21) : 5576 - 5581
  • [28] Detection of C-Reactive Protein based on a Dynabeads-labeled sandwich immunoassay by using a GMI biosensor
    Yang, Z.
    Lei, C.
    Zhou, Y.
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING: NEW ADVANCES, 2016, : 265 - 269
  • [29] Detection of C-Reactive Protein by Electrochemiluminescence-Based Droplet-Free Digital Immunoassay with Tyramide Signal Amplification
    Abe, Hiroya
    Nakamura, Shuri
    Ito, Kentaro
    Ino, Kosuke
    Liu, Zhengyi
    Sato, Shinichi
    Inoue, Kumi Y.
    Shiku, Hitoshi
    CHEMELECTROCHEM, 2025,
  • [30] On-the-fly rapid immunoassay for neonatal sepsis diagnosis: C-reactive protein accurate determination using magnetic graphene-based micromotors
    Molinero-Fernandez, Agueda
    Arruza, Luis
    Angel Lopez, Miguel
    Escarpa, Alberto
    BIOSENSORS & BIOELECTRONICS, 2020, 158 (158):