Performance and feasibility study of a heat pump with modified solar-air source evaporator: Techno-economic analysis for water heating

被引:0
|
作者
Chinnasamy, Subramaniyan [1 ]
Prakash, K. B. [1 ]
Divyabharathi, R. [2 ]
Kalidasan, B. [3 ]
Rajamony, Reji Kumar [4 ,5 ]
Pandey, A. K. [3 ,6 ]
Fouad, Yasser [7 ]
Soudagar, Manzoore Elahi M. [8 ,9 ]
机构
[1] Bannari Amman Inst Technol, Dept Mech Engn, Sathyamangalam 638401, Tamil Nadu, India
[2] Tamil Nadu Agr Univ, Dept Renewable Energy Engn, AEC &RI, Coimbatore 641003, India
[3] Sunway Univ, Res Ctr Nanomat & Energy Technol RCNMET, Sch Engn & Technol, Jalan Univ 5, Petaling Jaya 47500, Selangor Darul, Malaysia
[4] Natl Energy Univ, Univ Tenaga Nas, Inst Sustainable Energy, Jalan IKRAM UNITEN, Kajang, Selangor, Malaysia
[5] SIMATS, Saveetha Sch Engn, Dept Phys, Chennai 602105, India
[6] Uttaranchal Univ, CoE Energy & Ecosustainabil Res, Dehra Dun 248007, Uttarakhand, India
[7] King Saud Univ, Coll Appl Engn, Dept Appl Mech Engn, Muzahimiyah Branch, POB 800, Riyadh 11421, Saudi Arabia
[8] Lishui Univ, Fac Engn, Lishui 323000, Zhejiang, Peoples R China
[9] Era Graph, Dept Mech Engn, Dehra Dun 248002, Uttarakhand, India
关键词
Dual source; COP; Exergy; Heat pump; Carbon credit; Payback period; THERMAL PERFORMANCE; EXPERIMENTAL VALIDATION; ENERGY-CONSUMPTION; SYSTEM; SIMULATION; REFRIGERANTS; EMISSIONS; ASHP;
D O I
10.1016/j.icheatmasstransfer.2024.107795
中图分类号
O414.1 [热力学];
学科分类号
摘要
There is a rising demand for improving and analyzing the potential of alternative designs and operating conditions of heat pumps. The current study explores and reports on the techno-economic analysis (4E - Energy, Exergy, economic and environmental viability) of a Modified Dual Source Heat Pump (MDHP) water heater under various ambient and operating circumstances. There are three functioning modes are presented for operating the system all over the day irrespective of the ambient conditions: dual source with natural convection (MDHP-DN), dual source with forced convection (MDHP-DF), and air-source forced convection (MDHP-AF). The experimental analysis targeted to assess the system's overall performance under diverse design and operating conditions all over the day. The outcomes specify that the average COP of MDHP in dual source with natural convection mode (DN) is 7% and 18% larger than that of dual source with forced convection (DF) and (AF), respectively. The regular daily COP and exergy efficiency of MDHP (with five heat-up cycles per day) are 3.24 and 54.6%, respectively. Furthermore, the investigation into the annual effectiveness of the MDHP involves analyzing simulation studies that take into account the local ambient conditions. According to the results, the MDHP system has a payback period of around 689 days and a lifetime CO2 mitigation savings cost of approximately $178,057 compared to a conventional electric heating system. This inference implies that the suggested MDHP system can be adapted to varying weather conditions, providing active and long-term solutions compared with conventional heat pump water heating systems.
引用
下载
收藏
页数:19
相关论文
共 50 条
  • [31] Study the performance of air-source heat pump assisted solar water heating system
    Ding, Defeng
    Chen, Wu
    PROCEEDINGS OF THE 2017 GLOBAL CONFERENCE ON MECHANICS AND CIVIL ENGINEERING (GCMCE 2017), 2017, 132 : 396 - 400
  • [32] Techno-economic analysis of air source heat pump combined with latent thermal energy storage applied for space heating in China
    Yu, Meng
    Li, Sheng
    Zhang, Xuejun
    Zhao, Yang
    APPLIED THERMAL ENGINEERING, 2021, 185
  • [33] CLIMATE ADAPTATION ANALYSIS OF A SOLAR-AIR COMPOSITE HEAT SOURCE HEAT PUMP SYSTEM
    Liu, Y.
    Zhou, G. H.
    Shen, J. Y.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 840 - 845
  • [34] Linear Regression Analysis and Techno-Economic Viability of an Air Source Heat Pump Water Heater in a Residence at a University Campus
    Manyi-Loh, Christy E.
    Sikhonza, Mandlenkosi
    Tangwe, Stephen
    ENERGIES, 2021, 14 (08)
  • [35] Techno-economic and environmental analysis of a ground source heat pump for heating and cooling in Moroccan climate regions
    Ougazzou, Mouad
    El Maakoul, Anas
    Khay, Ismail
    Degiovanni, Alain
    Bakhouya, Mohamed
    ENERGY CONVERSION AND MANAGEMENT, 2024, 304
  • [36] Comparative analysis of solar-air dual source heat pump system with different heat source configurations
    Cai, Jingyong
    Zhang, Feng
    Ji, Jie
    Ji, Jie (jijie@ustc.edu.cn), 1600, Elsevier Ltd (150): : 191 - 203
  • [37] Techno-economic feasibility of absorption heat pumps using wastewater as the heating source for desalination
    Li, Hanning
    Russell, Nigel
    Sharifi, Vida
    Swithenbank, Jim
    DESALINATION, 2011, 281 : 118 - 127
  • [38] EXPERIMENTAL STUDY ON PERFORMANCE OF SOLAR-AIR ENERGY DUAL SOURCE COLLECTOR EVAPORATOR BASED ON FLAT HEAT PIPE
    Lou X.
    Quan Z.
    Zhao Y.
    Du B.
    Hou L.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2023, 44 (01): : 119 - 125
  • [39] TEMPERATURE CONTROL RESEARCH OF SOLAR-AIR SOURCE HEAT PUMP HEATING SYSTEM BASED ON ANFIS
    Tan, Xin
    Wu, Linfeng
    Yu, Qihui
    Liu, Zejiang
    Wang, Yahui
    Sun, Guoxin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2024, 45 (02): : 16 - 22
  • [40] Performance assessment and techno-economic optimization of ground source heat pump for residential heating and cooling: A case study of Nanjing, China
    Zhou, Kun
    Mao, Jinfeng
    Li, Yong
    Zhang, Hua
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2020, 40