Research and correction for over-response phenomenon when using inorganic scintillator optical fiber X-ray sensor to measure off-axis ratio (OAR)

被引:0
|
作者
He, Bo [1 ]
Xie, Tianci [1 ]
Hao, Wenjing [1 ]
Wang, Jingjing [1 ]
Yang, Haojie [1 ]
Chen, Ziyin [2 ]
Yang, Bin [3 ]
Shi, Qieming [1 ]
Qian, Jinqian [1 ]
Lewis, Elfed [4 ]
Sun, Weimin [1 ]
机构
[1] Harbin Engn Univ, Key Lab Infiber Integrated Opt, Minist Educ China, Harbin 150001, Peoples R China
[2] Harbin Med Univ, Affiliated Hosp 1, Comprehens Canc Ctr, Harbin 150001, Peoples R China
[3] Heilongjiang Inst Atom Energy, Harbin, Peoples R China
[4] Univ Limerick, Opt Fiber Sensors Res Ctr, Castletroy, Limerick, Ireland
基金
中国国家自然科学基金;
关键词
Radiotherapy; Fiber X-ray sensors; Over-response; Monte Carlo simulation; GEANT4; MONTE-CARLO-SIMULATION; RADIATION DOSIMETER; RADIOTHERAPY; INCIDENT; THERAPY;
D O I
10.1007/s10043-024-00914-3
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical fiber X-ray sensors have the potential to realize real-time dose monitoring of precision radiotherapy. However, an over-response phenomenon can occur when using an optical fiber sensor (OFXS) filled with inorganic scintillator (Gd2O2S:Tb) to measure the off-axis ratio (OAR) curve. The aim of this paper is to study the mechanism responsible for the over-response. Due to the complex particle distribution present in water phantoms, the Monte Carlo-based code GEANT4 was used to model the response of the scintillator. The energy response of the scintillator to photons and electrons was initially simulated, which subsequently allowed the OAR curve to be simulated and the results were compared with experiment. To analyze the energy distribution of particles in different positions, electron spectroscopy was simulated together with the photon spectrum at the position from the central axis to a distance of 14.5 cm away from the center. Finally, three metal (Al, Cu, Sn) caps were made for the OFXS to prevent the low-energy photons penetrating the OFXS, and the OARs measurements were repeated. The results show that the scintillator exhibits higher sensitivity to photons with energy below 0.5 MeV, while for electrons, the scintillator has a higher sensitivity to high-energy electrons. Simulations for electron spectroscopy and the photon spectrum show that there are many low-energy photons with relatively few low-energy electrons. The OARs measured using the OFXS with metal caps show that the over-response can be mitigated using a high-Z metal cap. The measurements demonstrate that the OAR cure measured using an OFXS fitted with a Sn cap exhibits the closest response to that measured using an IC.
引用
收藏
页数:12
相关论文
共 4 条
  • [1] GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor*
    Zhang, Bin
    Xie, Tian-Ci
    Qin, Zhuang
    Li, Hao-Peng
    Li, Song
    Zhao, Wen-Hui
    Chen, Zi-Yin
    Xu, Jun
    Lewis, Elfed
    Sun, Wei-Min
    [J]. CHINESE PHYSICS B, 2021, 30 (04)
  • [2] GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor
    张彬
    谢天赐
    秦壮
    李昊鹏
    李松
    赵文辉
    陈子印
    徐军
    Elfed Lewis
    孙伟民
    [J]. Chinese Physics B, 2021, 30 (04) : 732 - 738
  • [3] Effect of photons and electrons on the over-response of optical fiber X-ray sensors
    He, Bo
    Xie, Tianci
    Zhang, Bin
    Qian, Jinqian
    Li, Haopeng
    Shi, Qieming
    Hao, Wenjing
    Qin, Zhuang
    Lewis, Elfed
    Sun, Weimin
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376
  • [4] New model for explaining the over-response phenomenon in percentage of depth dose curve measured using inorganic scintillating materials for optical fiber radiation sensors
    Qin, Zhuang
    Xie, Tianci
    Dai, Xinyu
    Zhang, Bin
    Ma, Yu
    Khan, Ihsan Ullah
    Zhang, Xu
    Li, Haopeng
    Yan, Yongji
    Zhao, Wenhui
    Li, Song
    Chen, Ziyin
    Zhang, Daxin
    Xu, Jun
    Hu, Xiaokang
    Xing, Lina
    Feng, Kun
    Lewis, Elfed
    Sun, Weimin
    [J]. OPTICS EXPRESS, 2019, 27 (17): : 23693 - 23706