GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor

被引:1
|
作者
张彬 [1 ]
谢天赐 [1 ]
秦壮 [2 ]
李昊鹏 [1 ]
李松 [1 ]
赵文辉 [1 ]
陈子印 [3 ]
徐军 [4 ]
Elfed Lewis [5 ]
孙伟民 [1 ]
机构
[1] Key Laboratory of In-fiber Integrated Optics, Ministry of Education, Harbin Engineering University
[2] Electronic Engineering College, Ministry of Education, Heilongjiang University
[3] Comprehensive Cancer Center, First Affiliated Hospital of Harbin Medical University
[4] Comprehensive Cancer Center, Second Affiliated Hospital of Harbin Medical University
[5] Optical Fiber Sensors Research Centre, University of Limerick
基金
中国国家自然科学基金; 中央高校基本科研业务费专项资金资助;
关键词
D O I
暂无
中图分类号
TP212 [发送器(变换器)、传感器];
学科分类号
080202 ;
摘要
The purpose of this article is to explore the cause of the over-response phenomenon of fiber x-ray sensor.The sensor is based on a length of PMMA fiber,whose end is filled with the scintillation material Gd2O2S:Tb.The Monte Carlo simulation software GEANT4 uses the phase space file provided by the International Atomic Energy Agency(IAEA),by irradiating the fiber x-ray sensor in the water phantom,counting the fluorescence signal of the optical fiber x-ray sensor after propagation through the fiber.In addition,the number of Cerenkov photons propagating through the fiber is also counted.Comparing this article with previous research,we believe that one of the reasons for the over-response of the fiber x-ray sensor is the non-linear response of the deposition energy of the scintillator to the fluorescence.By establishing a region of interest and counting the x-rays in this region,the simulation results show that the counted number of x-rays that may affect the fiber x-ray sensor is the biggest in the area of interest at a water depth of 5 cm.This result is close to the maximum dose point of the experimental and simulated percentage depth dose(PDD) curve of fiber x-ray sensor.Therefore,the second reason of the over-response phenomenon is believed to be fact that the inorganic materials such as Gd2O2S:Tb have larger effective atomic numbers,so the fiber x-ray sensors will cause more collisions with x-ray in a low energy region of 0.1 MeV-1.5 MeV.
引用
收藏
页码:732 / 738
页数:7
相关论文
共 50 条
  • [1] GEANT4 simulation study of over-response phenomenon of fiber x-ray sensor*
    Zhang, Bin
    Xie, Tian-Ci
    Qin, Zhuang
    Li, Hao-Peng
    Li, Song
    Zhao, Wen-Hui
    Chen, Zi-Yin
    Xu, Jun
    Lewis, Elfed
    Sun, Wei-Min
    [J]. CHINESE PHYSICS B, 2021, 30 (04)
  • [2] Geant4 simulation of the response of phosphor screens for X-ray imaging
    Pistrui-Maximean, S. A.
    Freud, N.
    Letang, J. M.
    Koch, A.
    Munier, B.
    Walenta, A. H.
    Montarou, G.
    Babot, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01): : 196 - 199
  • [3] A GEANT4 based simulation for pixelated X-ray hybrid detectors
    Marinho, F.
    Akiba, K.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 772 : 50 - 51
  • [4] Fast simulation of x-ray transition radiation in the GEANT4 toolkit
    Grichine, VM
    [J]. ADVANCED MONTE CARLO FOR RADIATION PHYSICS, PARTICLE TRANSPORT SIMULATION AND APPLICATIONS, 2001, : 117 - 122
  • [5] GEANT4 simulation and spectrum restoration of a pixelated X-ray detector
    Tykhonov, Andrii
    Winkler, Alexander
    Smoliar, Volodymyr
    [J]. JOURNAL OF INSTRUMENTATION, 2023, 18 (04)
  • [6] X-ray tracing using Geant4
    Buis, E. J.
    Vacanti, G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 599 (2-3): : 260 - 263
  • [7] GEANT4 simulation of X-ray transition radiation at small angles
    Grichine, V. M.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [8] Effect of photons and electrons on the over-response of optical fiber X-ray sensors
    He, Bo
    Xie, Tianci
    Zhang, Bin
    Qian, Jinqian
    Li, Haopeng
    Shi, Qieming
    Hao, Wenjing
    Qin, Zhuang
    Lewis, Elfed
    Sun, Weimin
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2024, 376
  • [9] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Nasseri, Mohammad Mehdi
    [J]. PRAMANA-JOURNAL OF PHYSICS, 2019, 92 (04):
  • [10] Determination of molybdenum target parameters for transmission X-ray tube: A Geant4 simulation study
    Mohammad Mehdi Nasseri
    [J]. Pramana, 2019, 92