Performance of grayscale combined with contrast-enhanced ultrasound in differentiating benign and malignant pediatric ovarian masses

被引:0
|
作者
Hu, Zehang [1 ]
Fan, Shumin [1 ]
Feng, Xia [1 ]
Liu, Lei [1 ]
Zhou, Jingran [1 ]
Wu, Zhixia [1 ]
Zhou, Luyao [1 ]
机构
[1] Shenzhen Childrens Hosp, Dept Ultrasound, 7019 Yitian Rd, Shenzhen 518026, Peoples R China
基金
中国国家自然科学基金;
关键词
Children; Ultrasound; Ovary; Neoplasm; Contrast-enhanced ultrasound; FOCAL LIVER-LESIONS; ADNEXAL MASSES; TUMORS; US; MANAGEMENT; DIAGNOSIS; CHILDREN;
D O I
10.1007/s00330-024-11011-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate grayscale US combined with contrast-enhanced ultrasound (CEUS) in the preoperative differentiation between benign and malignant ovarian masses in a pediatric population. Materials and methods This retrospective study enrolled patients who underwent grayscale US and CEUS before surgery because of ovarian masses between July 2018 and September 2023, with available histopathologic or follow-up results. Two senior radiologists summarized the grayscale US and CEUS characteristics of all ovarian masses, including percentage of solidity, ascites, vascularity, and enhanced vessel morphology. These characteristics were then independently reviewed by radiologists with different experience to assess interobserver agreement. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUC), while interobserver agreement was evaluated by intraclass correlation coefficient (ICC). Results A total of 26 children (median age: 10.1 [7.5, 11.7] years; age range: 0-14 years; benign: 15 patients) were included. The main characteristics of malignant ovarian tumors were abundant blood flow and twisted blood vessels within the mass, enhanced portion of the mass over 50 percent (all p < 0.001). The grayscale US combined with CEUS showed better diagnostic performance than the grayscale US alone (AUC = 0.99 [95% CI: 0.95, 1.00] vs AUC = 0.70 [95% CI: 0.50, 0.90] p < 0.001). A statistically significant AUC before and after CEUS was also shown between two junior radiologists (0.75 vs 0.92 and 0.69 vs 0.86, respectively, both p < 0.05). ICC of CEUS was better than that of grayscale US among radiologists. Conclusion The combination of grayscale US and CEUS might improve the diagnostic accuracy in differentiating benign and malignant pediatric ovarian masses.
引用
收藏
页码:828 / 836
页数:9
相关论文
共 50 条
  • [31] Diagnostic accuracy of contrast-enhanced ultrasound in differentiating benign and malignant focal liver lesions: A retrospective study
    Ooi, Chin-Chin
    Low, Su-Chong Albert
    Schneider-Kolsky, Michal
    Lombardo, Paul
    Lim, Sze-Ying
    Abu Bakar, Rafidah
    Lo, Richard Hoau-Gong
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2010, 54 (05) : 421 - 430
  • [32] Quantitative and qualitative analysis of contrast-enhanced ultrasound for differentiating benign and malignant superficial enlarged lymph nodes
    Yue, Zong-Hua
    Du, Jia-Rui
    Li, Wen-Hui
    Zhang, Han-Yu
    Yin, Shao-Hua
    Huang, Mei-Yu
    Liu, Xing-Rui
    Sui, Guo-Qing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (09) : 6362 - 6373
  • [33] Contrast-enhanced ultrasound of benign and malignant liver lesions in children
    Fang, Cheng
    Anupindi, Sudha A.
    Back, Susan J.
    Franke, Doris
    Green, Thomas G.
    Harkanyi, Zoltan
    Jungert, Jorg
    Kwon, Jeannie K.
    Paltiel, Harriet J.
    Squires, Judy H.
    Zefov, Vassil N.
    McCarville, M. Beth
    PEDIATRIC RADIOLOGY, 2021, 51 (12) : 2181 - 2197
  • [34] A contrast-enhanced ultrasound study of benign and malignant breast tissue
    Barnard, Serita
    Leen, Edward
    Cooke, Timothy
    Angerson, Wilson
    SAMJ SOUTH AFRICAN MEDICAL JOURNAL, 2008, 98 (05): : 386 - 391
  • [35] Contrast-enhanced ultrasound of benign and malignant liver lesions in children
    Cheng Fang
    Sudha A. Anupindi
    Susan J. Back
    Doris Franke
    Thomas G. Green
    Zoltan Harkanyi
    Jörg Jüngert
    Jeannie K. Kwon
    Harriet J. Paltiel
    Judy H. Squires
    Vassil N. Zefov
    M. Beth McCarville
    Pediatric Radiology, 2021, 51 : 2181 - 2197
  • [36] Diagnostic performance of contrast-enhanced ultrasound combined with shear wave elastography in differentiating benign from malignant breast lesions: a systematic review and meta-analysis
    Chen, Xinyu
    Yu, Hairong
    Wei, Na
    Ozcan, Berat Bersu
    An, Guifang
    Wu, Qiong
    Wang, Ning
    GLAND SURGERY, 2023, 12 (11) : 1610 - 1623
  • [37] The application value of two-dimensional ultrasound combined with contrast-enhanced ultrasound in the differential diagnosis of benign, borderline, and malignant ovarian epithelial tumors
    Wang, Rongli
    Liu, Huiping
    Tang, Jun
    Geng, Jing
    JOURNAL OF OVARIAN RESEARCH, 2024, 17 (01)
  • [38] Differentiating between benign and malignant adnexal lesions with contrast-enhanced transvaginal ultrasonography
    Szymanski, Marek
    Socha, Maciej W.
    Kowalkowska, Magdalena E.
    Zielinska, Izabela B.
    Eljaszewicz, Andrzej
    Szymanski, Wieslaw
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2015, 131 (02) : 147 - 151
  • [39] Contrast-enhanced ultrasound features of malignant focal liver masses in dogs
    Burti, Silvia
    Zotti, Alessandro
    Rubini, Giuseppe
    Orlandi, Riccardo
    Bargellini, Paolo
    Bonsembiante, Federico
    Banzato, Tommaso
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [40] Contrast-enhanced ultrasound features of malignant focal liver masses in dogs
    Silvia Burti
    Alessandro Zotti
    Giuseppe Rubini
    Riccardo Orlandi
    Paolo Bargellini
    Federico Bonsembiante
    Tommaso Banzato
    Scientific Reports, 10