Splenic switch-off in [15O]H2O-positron emission tomography myocardial perfusion imaging using parametric blood flow images

被引:0
|
作者
Brorson, Jonas [1 ,2 ,3 ]
Gormsen, Lars Christian [1 ,2 ,4 ]
Madsen, Simon [1 ,2 ,4 ]
Tolbod, Lars Poulsen [1 ,2 ,4 ]
Jochumsen, Mads Ryo [1 ,2 ,4 ]
机构
[1] Aarhus Univ Hosp, Dept Nucl Med, Palle Juul Jensens Blvd 165, DK-8200 Aarhus N, Denmark
[2] Aarhus Univ Hosp, PET Ctr, Palle Juul Jensens Blvd 165, DK-8200 Aarhus N, Denmark
[3] Aarhus Univ, Dept Biomed, Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
关键词
Myocardial perfusion imaging; Adenosine; Splenic switch-off; O-15]H2O; PET; PET MPI; ADENOSINE; FUTURE;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Evaluation of sufficient adenosine response constitutes a significant challenge in myocardial perfusion imaging (MPI). Splenic switch-off in MPI studies denotes a visually (qualitatively) reduced splenic radiotracer signal during adenosine stress and is considered indicative of sufficient cardiac vasodilation. In this study, we examined semi-quantitative and quantitative approaches to splenic switch-off assessment using [O-15]H2O-PET with either summed activity images or calculated parametric splenic blood flow images. Methods: Cohort 1: 90 clinical patients undergoing [O-15]H2O MPI in whom adenosine response was considered clinically adequate were identified to characterize the corresponding splenic switch-off. Spleen stress/rest-ratio (SSR-ratio) was calculated as spleen stress signal intensity/spleen rest signal intensity on both summed activity and parametric blood flow images. Cohort 2: Twenty-five patients with repeat MPI due to suspected insufficient adenosine response were identified to observe if splenic switch-off on the initial MPI could predict the outcome of the repeat MPI.: Cohort 3: Fifty-four patients who were considered adenosine responders on MPI and who had a coronary angiogram (CAG) follow-up within 3 months after MPI served as a separate validation group. Results: Splenic switch-off was present in most patients with a clinically sufficient adenosine response (Cohort 1), illustrated by both visual (74.4%-86.7%), semi-quantitative (summed activity images) (85.6%), and quantitative (parametric blood flow images) (92.2%) evaluation, which corresponds to the distribution in patients with sufficient adenosine response and follow-up CAG (Cohort 3). In patients suspected of insufficient adenosine response on the initial MPI (Cohort 2), the repeat MPI only yielded different myocardial blood flow (MBF) results if the initial SSR-ratio was >0.90 on splenic parametric blood flow images. Conclusion: quantitative splenic switch-off assessment on parametric blood flow images was superior to the semi-quantitative splenic switch-off approach. Patients with a suspected insufficient initial adenosine response and SSR-ratio >0.90 can benefit from a repeat MPI. Thus, the integration of quantitative splenic switch-off using parametric blood flow images in the evaluation of adenosine response may support future clinical decision-making.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Continuous thermodilution to assess absolute flow and microvascular resistance: validation in humans using [15O]H2O positron emission tomography
    Everaars, Henk
    de Waard, Guus A.
    Schumacher, Stefan P.
    Zimmermann, Frederik M.
    Bom, Michiel J.
    van de Ven, Peter M.
    Raijmakers, Pieter G.
    Lammertsma, Adriaan A.
    Gotte, Marco J.
    van Rossum, Albert C.
    Kurata, Akira
    Marques, Koen M. J.
    Pijls, Nico H. J.
    van Royen, Niels
    Knaapen, Paul
    EUROPEAN HEART JOURNAL, 2019, 40 (28) : 2350 - 2359
  • [42] DELINEATION OF IMPAIRED REGIONAL MYOCARDIAL PERFUSION BY POSITRON EMISSION TOMOGRAPHY WITH (H15O)-H-2
    WALSH, MN
    BERGMANN, SR
    STEELE, RL
    KENZORA, JL
    TERPOGOSSIAN, MM
    SOBEL, BE
    GELTMAN, EM
    CIRCULATION, 1988, 78 (03) : 612 - 620
  • [43] Cerebral blood flow measured by MRI bolus tracking in pips with acute stroke:: Comparison with [15o] H2o positron emission tomography
    Sakoh, M
    Rohl, L
    Simonsen, CZ
    Smith, DF
    Poulsen, PV
    Gyldensted, C
    Sakaki, S
    Gjedde, A
    Oestergaard, L
    STROKE, 2000, 31 (01) : 305 - 305
  • [44] Preamputation Evaluation of Lower-Limb Skeletal Muscle Perfusion with H2 15O Positron Emission Tomography
    Scremin, Oscar U.
    Figoni, Stephen F.
    Norman, Keith
    Scremin, A. M. Erika
    Kunkel, Charles F.
    Opava-Rutter, Dorene
    Schmitter, Eric D.
    Bert, Alberto
    Mandelkern, Mark
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2010, 89 (06) : 473 - 486
  • [45] Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner
    Harms, Hendrik J.
    Knaapen, Paul
    de Haan, Stefan
    Halbmeijer, Rick
    Lammertsma, Adriaan A.
    Lubberink, Mark
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (05) : 930 - 939
  • [46] [15O]H2O myocardial perfusion positron emission tomography: Added value of relative stress perfusion deficit in the prediction of significant coronary artery stenosis in a mixed population
    Mark, Peter D.
    Prescott, Eva
    Marner, Lisbeth
    Hovind, Peter
    Krakauer, Martin
    JOURNAL OF NUCLEAR CARDIOLOGY, 2024, 37
  • [47] Automatic generation of absolute myocardial blood flow images using [15O]H2O and a clinical PET/CT scanner
    Hendrik J. Harms
    Paul Knaapen
    Stefan de Haan
    Rick Halbmeijer
    Adriaan A. Lammertsma
    Mark Lubberink
    European Journal of Nuclear Medicine and Molecular Imaging, 2011, 38 : 930 - 939
  • [48] Effect of seizures on cerebral blood flow measured with O-15-H2O and positron emission tomography
    Theodore, WH
    Balish, M
    Leiderman, D
    Bromfield, E
    Sato, S
    EPILEPSIA, 1996, 37 (08) : 796 - 802
  • [49] Cerebral blood flow and blood volume measured by magnetic resonance imaging bolus tracking after acute stroke in pigs -: Comparison with [15O]H2O positron emission tomography
    Sakoh, M
    Rohl, L
    Gyldensted, C
    Gjedde, A
    Ostergaard, L
    STROKE, 2000, 31 (08) : 1958 - 1964
  • [50] Global and segmental absolute stress myocardial blood flow in prediction of cardiac events: [15O] water positron emission tomography study
    Harjulahti, Esa
    Maaniitty, Teemu
    Nammas, Wail
    Stenstrom, Iida
    Biancari, Fausto
    Bax, Jeroen J.
    Knuuti, Juhani
    Saraste, Antti
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (05) : 1434 - 1444