Corneal epithelial thickness mapping by optical coherence tomography in normal and early keratoconic eyes

被引:0
|
作者
El Gazzar, Hamdy Ahmed [1 ]
Masoud, Mohamed [1 ]
Wagih, Alyaa [2 ]
Al-Tohamy, Soha Moussa [1 ]
机构
[1] Benha Univ, Fac Med, Ophthalmol Dept, Banha, Egypt
[2] MMBCH, Mansoura, Egypt
关键词
epithelial thickness; keratoconus; spectral domain-optical coherence tomography; PEDIATRIC KERATOCONUS; PROFILE;
D O I
10.4103/ejos.ejos_45_23
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background Keratoconus (KC) is a noninflammatory disease causing anatomical deformity of the cornea and is manifested by marked conical protrusion in addition to thinning of the corneal central part. There are currently no standardized screening criteria for KC, making early diagnosis difficult. Early diagnosis aids in stopping progression and better management. It has been proposed that spectral domain optical coherence tomography (SD-OCT) has a diagnostic advantage in the early detection of corneal thickness changes in early KC. Aim Detection of corneal epithelial thickness changes in early KC eyes versus normal eyes using SD-OCT. Methods The research involved 30 eyes with early KC and 30 eyes from healthy control patients. Both groups underwent detailed ophthalmological examination and measurement of regional corneal epithelial thickness with anterior segment SD-OCT. Results In the cases group, corneal epithelium thickness decreased significantly in all regions tested. Additionally, all parameters of the pentacam pachymetry indices showed a statistically significant increase in the cases group. All of the thinnest pachymetry at central 5 mm and 7 mm Area Under the Curve (AUC=0.822 and 0.804), the location Y at central 5 mm and 7 mm (AUC=0.796 and 0.738), the minimum-maximum at central 5 mm and 7 mm (AUC=0.878 and 0.934), and the standard of deviation at central 5 mm and 7 mm (AUC=0.935 and 0.941) showed a statistically significant predictive value for differentiation KC cases from control (P < 0.001), with the highest AUC reported with the standard of deviation. The tested corneal thickness in various regions correlated positively and statistically significantly with pentacam pachymetry indices. Conclusions Early KC is associated with corneal thinning and increased pentacam pachymetry index parameters. The changes detected by pentacam pachymetry and epithelial thickness as detected by SD-OCT showed a significant correlation.
引用
收藏
页码:254 / 263
页数:10
相关论文
共 50 条
  • [21] Repeatability of Corneal Epithelial Thickness Measurements Using Fourier-Domain Optical Coherence Tomography in Normal and Post-LASIK Eyes
    Ma, Xingxuan Jack
    Wang, Li
    Koch, Douglas D.
    CORNEA, 2013, 32 (12) : 1544 - 1548
  • [22] Corneal Enantiomorphism in Normal and Keratoconic Eyes
    Saad, Alain
    Guilbert, Emmanuel
    Gatinel, Damien
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (08) : 542 - 548
  • [23] Corneal, limbal, and conjunctival epithelial thickness from Optical Coherence Tomography
    Feng, Yunwei
    Simpson, Trefford L.
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (09) : 880 - 883
  • [24] Corneal and corneal epithelial thickness distribution characteristics in healthy North Indian eyes using spectral domain optical coherence tomography
    Malhotra, Chintan
    Gupta, Barkha
    Dhiman, Rajneesh
    Jain, Arun K.
    Gupta, Amit
    Ram, Jagat
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1171 - 1178
  • [25] Simultaneous Corneal Topography and Epithelial Thickness Mapping from a Single Measurement Using Optical Coherence Tomography
    Sikorski, Bartosz L.
    JOURNAL OF OPHTHALMOLOGY, 2022, 2022
  • [26] Agreement Between Swept-source Optical Coherence Tomography and Rotating Scheimpflug Camera in Measurement of Corneal Parameters in Normal and Keratoconic Eyes
    Ghassemi, Hamed
    Zarei-Ghanavati, Mehran
    Khastavan, Mina
    Atighehchian, Mehrnaz
    Khorasani, Abbas Azimi
    Latifi, Golshan
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2023, 18 (04) : 386 - 395
  • [27] Diurnal variation of corneal and corneal epithelial thickness measured using optical coherence tomography
    Feng, YW
    Varikooty, J
    Simpson, TL
    CORNEA, 2001, 20 (05) : 480 - 483
  • [28] Intraoperative Corneal Thickness Measurement by Optical Coherence Tomography in Keratoconic Patients Undergoing Corneal Collagen Cross-Linking
    Mazzotta, Cosimo
    Caragiuli, Stefano
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (06) : 1156 - 1162
  • [29] Optical coherence tomography-derived corneal thickness asymmetry indices: Clinical reference study of normal eyes
    Kanellopoulos, Anastasios John
    Chiridou, Marianthi
    Asimellis, George
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (10): : 1603 - 1609
  • [30] Evaluation of central and peripheral corneal thickness with ultrasound biomicroscopy in normal and keratoconic eyes
    Avitabile, T
    Marano, F
    Uva, MG
    Reibaldi, A
    CORNEA, 1997, 16 (06) : 639 - 644