Non-invasive hemoglobin measurement using optical method

被引:0
|
作者
Ranjith, R. [1 ]
Priya, S. [1 ]
Dharshini, A. S. Kaviya [1 ]
Jeeva, J. B. [1 ]
机构
[1] VIT Univ, Sch Elect Engn, Vellore, India
关键词
Photoplethysmography; Beer-Lambert law; Hemoglobin (Hb); Non-invasive; EXTINCTION COEFFICIENTS; SYSTEM;
D O I
10.1016/j.heliyon.2024.e35777
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The measurement of Hemoglobin (Hb) by the non-invasive method is gaining popularity. The system, consisting of a photodiode is placed in between a Red (630 nm) and an IR (940 nm) LED, along with the signal conditioning circuits. 10 healthy male (8) and female (2) volunteers in the age group between 21 and 24 were recruited for this study. During measurement, the fingertip of a volunteer was placed on the measurement pad. Visible and IR lights are switched ON one after the other. The optical absorbance of the blood component in the arteries was detected by the photodiode using the reflectance method. The current generated was converted into voltage and was processed to remove the noise associated with the signal. From this, the concentration of Hb of the volunteers was determined. On the same day they were taken to the clinical laboratory and Hb values were obtained by the standard invasive method. Hemoglobin values obtained from the two methods were compared and an accuracy of 96.31 % and correlation coefficient value of 0.932405 was achieved. From the Bland -Altman plot, the results obtained are within the confidence interval of 95 %. The error of 3 % can be reduced further by employing sophisticated signal conditioning techniques. The proposed non-invasive method took only a few seconds to find the hemoglobin concentration than the invasive lab test. This method can accelerate the decision-making process in emergency situations.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] MULTIFACTORIAL DEPENDENCY AND EVALUATION OF HEMOGLOBIN, DETERMINED BY NON-INVASIVE AND INVASIVE MEASUREMENT IN BLOOD DONORS
    Bohonek, M. B.
    Petras, M.
    Kricnerova, M.
    Sladkova, E.
    VOX SANGUINIS, 2013, 105 : 116 - 117
  • [42] Non-invasive optical techniques for the measurement of macular pigments
    Ermakov, IV
    Ermakova, MR
    Gellermann, W
    Bernstein, PS
    OPHTHALMIC TECHNOLOGIES XIII, 2003, 4951 : 185 - 195
  • [43] Non-invasive measurement of hemoglobin during cesarean hysterectomy: a case series
    Butwick, A. J.
    Hilton, G.
    Riley, E. T.
    Carvalho, B.
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2011, 20 (03) : 240 - 245
  • [44] Dynamic Spectrum and BP Neural Network for Non-invasive Hemoglobin Measurement
    Wang, Huiquan
    Li, Gang
    Zhao, Zhe
    Lin, Ling
    LIFE SYSTEM MODELING AND INTELLIGENT COMPUTING, 2010, 6330 : 67 - 74
  • [45] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Hahn, Robert G.
    Wuethrich, Patrick Y.
    Zdolsek, Joachim H.
    BMC ANESTHESIOLOGY, 2021, 21 (01)
  • [46] A Novel Non-Invasive Technology for Hemoglobin Measurement Irrespective of the Skin Color
    Gokhale, S.
    Daggubati, V.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [47] A novel device for the non-invasive measurement of free hemoglobin in blood bags
    Meinke, M
    Friebel, M
    Helfmann, J
    Notter, M
    BIOMEDIZINISCHE TECHNIK, 2005, 50 (1-2): : 2 - 7
  • [48] Non-invasive measurement of functional optical brain changes
    Grattan, G
    Fabiani, M
    Foundations of Augmented Cognition, Vol 11, 2005, : 204 - 204
  • [49] Can perioperative hemodilution be monitored with non-invasive measurement of blood hemoglobin?
    Robert G. Hahn
    Patrick Y. Wuethrich
    Joachim H. Zdolsek
    BMC Anesthesiology, 21
  • [50] Application of EMD Algorithm to the Dynamic Spectrum Non-Invasive Measurement of Hemoglobin
    Lin Ling
    Li Wei
    Zhou Mei
    Zeng Rui-li
    Li Gang
    Zhang Bao-ju
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2014, 34 (08) : 2106 - 2111