Performance stability of plastics for neutron-gamma pulse shape discrimination

被引:0
|
作者
Zaitseva, Natalia [1 ]
Carman, Leslie [1 ]
Glenn, Andrew [1 ]
Kim, Yongwook [1 ]
Ford, Michael [1 ]
Eccleston, Gracie [2 ]
Hurlbut, Charles [3 ]
Shipp, Kyle [3 ]
机构
[1] Lawrence Livermore Natl Lab, 7000 East Ave, Livermore, CA 94551 USA
[2] Georgia Inst Technol, North Ave NW, Atlanta, GA 30332 USA
[3] Eljen Technol, 1300 W Broadway, Sweetwater, TX 79556 USA
关键词
Organic scintillator; Pulse shape discrimination; PSD plastic; 6 Li-loaded plastic; Plastic degradation; Neutron detection; SCINTILLATION;
D O I
10.1016/j.nima.2024.169731
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5-10 years in comparison to previous EJ-276 that might lose up to 30-40 % of the scintillation light during 1-2 years of storage or deployment under ambient conditions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Optimization of pulse processing parameters for digital neutron-gamma discrimination
    Lotfi, Y.
    Moussavi-Zarandi, S. A.
    Ghal-Eh, N.
    Bayat, E.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2019, 164
  • [22] Calibration of EJ-276 plastic scintillator for neutron-gamma pulse shape discrimination experiments
    Ryabeva, E. V.
    Urupa, I. V.
    Lupar, E. E.
    Kadilin, V. V.
    Skotnikova, A. V.
    Kokorev, Y. A.
    Ibragimov, R. F.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1010
  • [23] Neutron-gamma discrimination by pulse analysis with superheated drop detector
    Das, Mala
    Seth, S.
    Saha, S.
    Bhattacharya, S.
    Bhattacharjee, P.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 622 (01): : 196 - 199
  • [24] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Jiahao Xu
    Wei Cheng
    Wenbao Jia
    Qingbo Chen
    Ronghua Zhang
    Yan Zhang
    Can Cheng
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 905 - 916
  • [25] Temperature Dependence of Neutron-Gamma Discrimination Based on Pulse Shape Discrimination Technique in a Ce : LiCaAlF6 Scintillator
    Watanabe, Kenichi
    Kondo, Yoshiyuki
    Yamazaki, Atsushi
    Uritani, Akira
    Iguchi, Tetsuo
    Kawaguchi, Noriaki
    Fukuda, Kentaro
    Ishidu, Sumito
    Yanagida, Takayuki
    Fujimoto, Yutaka
    Yoshikawa, Akira
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 959 - 962
  • [26] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Xu, Jiahao
    Cheng, Wei
    Jia, Wenbao
    Chen, Qingbo
    Zhang, Ronghua
    Zhang, Yan
    Cheng, Can
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 905 - 916
  • [27] NEUTRON-GAMMA DISCRIMINATION BASED ON LEADING-EDGE SHAPE MEASUREMENT
    BOSE, S
    CHATTERJEE, MB
    SINHA, BK
    BHATTACHARYYA, R
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 270 (2-3): : 487 - 491
  • [28] ON NEUTRON-GAMMA DISCRIMINATION IN NAI(TL)
    BELLI, P
    BERNABEI, R
    INCICCHITTI, A
    PROSPERI, D
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (1-2): : 391 - 392
  • [29] A PRACTICAL METHOD OF NEUTRON-GAMMA DISCRIMINATION
    KAHANE, J
    SENE, R
    DELPIERRE, P
    HEYMAN, M
    [J]. REVUE DE PHYSIQUE APPLIQUEE, 1969, 4 (02): : 257 - +
  • [30] DEVELOPMENT OF A NEUTRON-GAMMA DISCRIMINATION CIRCUIT
    ADAM, A
    CABE, J
    CANCE, M
    LAURAT, M
    PONCE, JC
    [J]. REVUE DE PHYSIQUE APPLIQUEE, 1969, 4 (02): : 262 - &