Mass Concentration and Removal Characteristics of Microplastics and Nanoplastics in a Drinking Water Treatment Plant

被引:2
|
作者
Xu, Yanghui [1 ,2 ]
Ou, Qin [1 ,2 ]
Wang, Xintu [1 ,3 ]
van der Hoek, Jan Peter [2 ,4 ]
Liu, Gang [1 ,5 ]
机构
[1] Chinese Acad Sci, Key Lab Drinking Water Sci & Technol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Dept Water Management, Sect Sanit Engn, NL-2628 CN Delft, Netherlands
[3] Guilin Univ Technol, Coll Environm Sci & Engn, Guangxi 541004, Peoples R China
[4] Waternet, Dept Res & Innovat, NL-1090 GJ Amsterdam, Netherlands
[5] Univ Chinese Acad Sci, Beijing 100040, Peoples R China
来源
ACS ES&T WATER | 2024年 / 4卷 / 08期
基金
中国国家自然科学基金;
关键词
microplastics; nanoplastics; mass concentration; drinking water; drinking water treatment; Py-GC/MS; ENVIRONMENTAL-SAMPLES; MARINE-ENVIRONMENT; IDENTIFICATION; QUANTIFICATION; PARTICLES; COMPLEX; MICROSCOPY; IMPACTS; FATE;
D O I
10.1021/acsestwater.4c00222
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The occurrence and removal of microplastics (MPs) in drinking water treatment plants (DWTPs) have been evaluated based on particle number, while the mass concentration and removal characteristics based on the mass of MPs, and especially nanoplastics (NPs), remain unknown. This study employed pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) to determine the mass concentration of MPs and NPs with different size ranges (0.01-1, 1-50, and 50-1000 mu m) across the entire treatment process in a DWTP. The total polymers were measured at 9.63 +/- 1.52 mu g/L in raw water and 0.77 +/- 0.05 mu g/L in treated water, with the dominant polymers being polypropylene and polyethylene terephthalate. NPs (0.01-1 mu m) accounted for only 3.2-5.3% of the total polymers, with an average concentration of 0.38 mu g/L in raw water and 0.04 mu g/L in treated water. Notably, NPs and sub-MPs (1-50 mu m) demonstrated relatively low efficiency in the DWTP at 88.9 +/- 3.2 and 88.0 +/- 2.5%, respectively, compared with that of the large MPs (50-1000 mu m) at 92.9 +/- 0.3%. Overall, this study examined the occurrence of MPs and NPs, in a DWTP, emphasizing the significance of considering the mass concentration of MPs and NPs when assessing their pollution levels and removal characteristics.
引用
收藏
页码:3348 / 3358
页数:11
相关论文
共 50 条
  • [41] Microplastics in Freshwater and Drinking Water: Sources, Impacts, Detection, and Removal Strategies
    Chowdhury, Saidur Rahman
    Razzak, Shaikh Abdur
    Hassan, Ikrema
    Hossain, S. M. Zakir
    Hossain, Mohammad Mozahar
    [J]. WATER AIR AND SOIL POLLUTION, 2023, 234 (11):
  • [42] Occurrence and Characteristics of Microplastics in a Wastewater Treatment Plant
    Zhang, Yunhai
    Wang, Hao
    Xu, Jimin
    Su, Xin
    Lu, Meichi
    Wang, Zhiyuan
    Zhang, Yongjun
    [J]. BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 2021, 107 (04) : 677 - 683
  • [43] Occurrence and Characteristics of Microplastics in a Wastewater Treatment Plant
    Yunhai Zhang
    Hao Wang
    Jimin Xu
    Xin Su
    Meichi Lu
    Zhiyuan Wang
    Yongjun Zhang
    [J]. Bulletin of Environmental Contamination and Toxicology, 2021, 107 : 677 - 683
  • [44] Occurrence and removal of pesticides in the drinking water treatment plant of Thessaloniki, northern Greece
    Zambetoglou, Konstantinos
    Papagianni, Maria
    Papaioannou, Anastasios
    Charalambidou, Aikaterini
    Samara, Constantini
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2006, 15 (9A): : 989 - 996
  • [45] Enhancing the particle removal efficiency of a drinking water treatment plant by membrane filtration
    Hagmeyer, G
    Kiepke, O
    Dautzenberg, W
    Gimbel, R
    [J]. MEMBRANES IN DRINKING AND INDUSTRIAL WATER PRODUCTION II, 2001, 1 (5-6): : 377 - 380
  • [46] A practical approach on reuse of drinking water treatment plant residuals for fluoride removal
    Shakya, Arvind Kumar
    Bhande, Ranjeeta
    Ghosh, Pranab Kumar
    [J]. ENVIRONMENTAL TECHNOLOGY, 2020, 41 (22) : 2907 - 2919
  • [47] Characteristics of microplastic removal via coagulation and ultrafiltration during drinking water treatment
    Ma, Baiwen
    Xue, Wenjing
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    Li, Liangliang
    [J]. CHEMICAL ENGINEERING JOURNAL, 2019, 359 : 159 - 167
  • [48] Algae removal characteristics of the ultrasonic radiation enhanced drinking water treatment process
    Peng, Yazhou
    Yang, Xiongwei
    Ren, Bozhi
    Zhang, Zhi
    Deng, Xinping
    Yin, Wei
    Zhou, Saijun
    Yang, Siyuan
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2023, 55
  • [49] Characteristics of microplastic removal via coagulation and ultrafiltration during drinking water treatment
    Ma, Baiwen
    Xue, Wenjing
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    Li, Liangliang
    [J]. Chemical Engineering Journal, 2019, 359 : 159 - 167
  • [50] Identification, Quantification, and Evaluation of Microplastics Removal Efficiency in a Water Treatment Plant (A Case Study in Iran)
    Sharifi, Hamze
    Attar, Hossein Movahedian
    [J]. AIR SOIL AND WATER RESEARCH, 2022, 15