Mass Concentration and Removal Characteristics of Microplastics and Nanoplastics in a Drinking Water Treatment Plant

被引:2
|
作者
Xu, Yanghui [1 ,2 ]
Ou, Qin [1 ,2 ]
Wang, Xintu [1 ,3 ]
van der Hoek, Jan Peter [2 ,4 ]
Liu, Gang [1 ,5 ]
机构
[1] Chinese Acad Sci, Key Lab Drinking Water Sci & Technol, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
[2] Delft Univ Technol, Fac Civil Engn & Geosci, Dept Water Management, Sect Sanit Engn, NL-2628 CN Delft, Netherlands
[3] Guilin Univ Technol, Coll Environm Sci & Engn, Guangxi 541004, Peoples R China
[4] Waternet, Dept Res & Innovat, NL-1090 GJ Amsterdam, Netherlands
[5] Univ Chinese Acad Sci, Beijing 100040, Peoples R China
来源
ACS ES&T WATER | 2024年 / 4卷 / 08期
基金
中国国家自然科学基金;
关键词
microplastics; nanoplastics; mass concentration; drinking water; drinking water treatment; Py-GC/MS; ENVIRONMENTAL-SAMPLES; MARINE-ENVIRONMENT; IDENTIFICATION; QUANTIFICATION; PARTICLES; COMPLEX; MICROSCOPY; IMPACTS; FATE;
D O I
10.1021/acsestwater.4c00222
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The occurrence and removal of microplastics (MPs) in drinking water treatment plants (DWTPs) have been evaluated based on particle number, while the mass concentration and removal characteristics based on the mass of MPs, and especially nanoplastics (NPs), remain unknown. This study employed pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) to determine the mass concentration of MPs and NPs with different size ranges (0.01-1, 1-50, and 50-1000 mu m) across the entire treatment process in a DWTP. The total polymers were measured at 9.63 +/- 1.52 mu g/L in raw water and 0.77 +/- 0.05 mu g/L in treated water, with the dominant polymers being polypropylene and polyethylene terephthalate. NPs (0.01-1 mu m) accounted for only 3.2-5.3% of the total polymers, with an average concentration of 0.38 mu g/L in raw water and 0.04 mu g/L in treated water. Notably, NPs and sub-MPs (1-50 mu m) demonstrated relatively low efficiency in the DWTP at 88.9 +/- 3.2 and 88.0 +/- 2.5%, respectively, compared with that of the large MPs (50-1000 mu m) at 92.9 +/- 0.3%. Overall, this study examined the occurrence of MPs and NPs, in a DWTP, emphasizing the significance of considering the mass concentration of MPs and NPs when assessing their pollution levels and removal characteristics.
引用
收藏
页码:3348 / 3358
页数:11
相关论文
共 50 条
  • [1] Fate and removal efficiency of polystyrene nanoplastics in a pilot drinking water treatment plant
    Arenas, Lina Ramirez
    Gentile, Stephan Ramseier
    Zimmermann, Stephane
    Stoll, Serge
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2022, 813
  • [2] Occurrence and removal of microplastics in an advanced drinking water treatment plant (ADWTP)
    Wang, Zhifeng
    Lin, Tao
    Chen, Wei
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2020, 700
  • [3] Microplastics removal efficiency of drinking water treatment plant with pulse clarifier
    Sarkar, Dhruba Jyoti
    Sarkar, Soma Das
    Das, Basanta Kumar
    Praharaj, Jaya Krushna
    Mahajan, Dev Kumar
    Purokait, Bidesh
    Mohanty, Trupty Rani
    Mohanty, Debasmita
    Gogoi, Pranab
    Kumar, V. Santhana
    Behera, Bijay Kumar
    Manna, Ranjan Kumar
    Samanta, Srikanta
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2021, 413
  • [4] Removal of microplastics and nanoplastics in water treatment processes: A systematic literature review
    Romphophak, Ploypailin
    Faikhaw, Orasai
    Sairiam, Sermpong
    Thuptimdang, Pumis
    Coufort-Saudejaud, Carole
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2024, 64
  • [5] Contamination and Removal Efficiency of Microplastics and Synthetic Fibres in a Conventional Drinking Water Treatment Plant
    Velasco, Angel Negrete
    Gentile, Stephan Ramseier
    Zimmermann, Stephane
    Stoll, Serge
    [J]. FRONTIERS IN WATER, 2022, 4
  • [6] Enhancing the removal efficiency of microplastics in drinking water treatment
    Tang, Shuyuan
    Gao, Ling
    Zhao, Tianrui
    Tian, Aisi
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2024, 57
  • [7] Removal characteristics of microplastics by Fe-based coagulants during drinking water treatment
    Baiwen Ma
    Wenjing Xue
    Yanyan Ding
    Chengzhi Hu
    Huijuan Liu
    Jiuhui Qu
    [J]. Journal of Environmental Sciences, 2019, (04) : 267 - 275
  • [8] Removal characteristics of microplastics by Fe-based coagulants during drinking water treatment
    Ma, Baiwen
    Xue, Wenjing
    Ding, Yanyan
    Hu, Chengzhi
    Liu, Huijuan
    Qu, Jiuhui
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCES, 2019, 78 : 267 - 275
  • [9] The coagulation behavior and removal efficiency of microplastics in drinking water treatment
    Tang, Shuyuan
    Gao, Ling
    Tian, Aisi
    Zhao, Tianrui
    Zou, Donglei
    [J]. JOURNAL OF WATER PROCESS ENGINEERING, 2023, 53
  • [10] Conventional and biological treatment for the removal of microplastics from drinking water
    Cherniak, Samuel L.
    Almuhtaram, Husein
    McKie, Michael J.
    Hermabessiere, Ludovic
    Yuan, Chuqiao
    Rochman, Chelsea M.
    Andrews, Robert C.
    [J]. CHEMOSPHERE, 2022, 288