Comparing a Head-Mounted Smartphone Visual Field Analyzer to Standard Automated Perimetry in Glaucoma: A Prospective Study

被引:0
|
作者
Wang, Sean K. [1 ]
Tran, Elaine M. [1 ]
Yan, William [2 ]
Kosaraju, Reshma [3 ]
Sun, Yang [1 ]
Chang, Robert T. [1 ]
机构
[1] Stanford Univ, Byers Eye Inst, Dept Ophthalmol, Palo Alto, CA USA
[2] Royal Victorian Eye & Ear Hosp, Dept Ophthalmol, East Melbourne, Vic, Australia
[3] Harker Sch, San Jose, CA USA
关键词
glaucoma; visual field; perimetry; smartphone; head-mounted;
D O I
10.1097/IJG.0000000000002452
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: Wang et al compare an FDA-registered head-mounted smartphone device (PalmScan VF2000) with standard automated perimetry (SAP) in glaucoma patients and find that the head-mounted device may not fully recapitulate SAP testing. Purpose: This study prospectively compared visual field testing using the PalmScan VF2000 Visual Field Analyzer, a head-mounted smartphone device, with standard automated perimetry (SAP). Methods: Patients with glaucoma undergoing Humphrey Field Analyzer SAP testing were asked to complete in-office PalmScan testing using a Samsung S5 smartphone in a virtual reality-style headset. Glaucoma severity was defined as SAP mean deviation (MD) >-6 dB for mild, between -6 and -12 dB for moderate, and <-12 dB for severe. Global parameters MD and pattern SD from PalmScan and SAP were compared using t-tests and Bland-Altman analyses. Bland-Altmann analyses of PalmScan and SAP MD were conducted for the superonasal, superotemporal, inferonasal, and inferotemporal visual field quadrants. The repeatability of PalmScan was assessed using Spearman's correlations and intraclass correlation coefficients (ICCs). Results: Fifty-one patients (51 eyes) completed both SAP and PalmScan testing and met the criteria for analysis. Compared with SAP, global MD and pattern SD measurements from PalmScan differed by an average of +0.62 +/- 0.26 dB (range: -3.25 to +4.60 dB) and -1.00 +/- 0.24 dB (range: -6.03 to +2.77 dB), respectively, while MD scores from individual visual field quadrants differed by as much as -6.58 to +11.43 dB. The agreement between PalmScan and SAP in classifying glaucoma severity was 86.3% across all eyes. PalmScan and SAP identified the same quadrant as having the worst visual field defect in 66.7% of eyes. Conclusions: Despite advantages in cost and accessibility, the PalmScan head-mounted perimetry device may not be able to fully recapitulate SAP testing.
引用
收藏
页码:742 / 747
页数:6
相关论文
共 50 条
  • [41] Feasibility of testing visual motor function through a smartphone app in a comparative study evaluating head-mounted display systems
    Deemer, Ashley
    Fujiwara, Kyoko
    Deremeik, James
    Bradley, Chris
    Chun, Rob
    Werblin, Frank S.
    Massof, Robert W.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [42] COMPARISON OF FLICKER PERIMETRY AND STANDARD PERIMETRY IN EARLY GLAUCOMA AND OCULAR HYPERTENSION - LOCAL VISUAL-FIELD CHANGES
    CASSON, EJ
    JOHNSON, CA
    NELSONQUIGG, JM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 1104 - 1104
  • [43] Comparison of frequency doubling technology and standard automated perimetry for detecting glaucomatous visual field progression. A longitudinal prospective study.
    Haymes, SA
    Artes, PH
    Hutchison, DM
    McCormick, T
    Varma, DK
    Nicolela, MT
    LeBlanc, RP
    Chauhan, BC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U146 - U146
  • [44] GearVision: Smartphone Based Head Mounted Perimeter For Detection Of Visual Field Defects
    Sircar, Tushar
    Mishra, Aarshee
    Bopardikar, Ajit
    Tiwari, Vijay Narayan
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 5402 - 5405
  • [45] Diffuse and localised visual field defects to automated perimetry in primary open angle glaucoma
    Mutlukan, E
    EYE, 1995, 9 : 745 - 750
  • [46] Detection of visual field progression in glaucoma with standard achromatic perimetry: A review and practical implications
    Kouros Nouri-Mahdavi
    Nariman Nassiri
    Annette Giangiacomo
    Joseph Caprioli
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 1593 - 1616
  • [47] Detection of visual field progression in glaucoma with standard achromatic perimetry: A review and practical implications
    Nouri-Mahdavi, Kouros
    Nassiri, Nariman
    Giangiacomo, Annette
    Caprioli, Joseph
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (11) : 1593 - 1616
  • [48] COURSE OF VISUAL-FIELD LOSS ON AUTOMATED PERIMETRY IN CHRONIC GLAUCOMA STABILIZED BY TRABECULECTOMY
    BOISSONNOT, M
    HIRSCH, AL
    ROVIRA, JC
    RISSE, JF
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1992, 15 (12): : 645 - 650
  • [49] Towards Efficient Visual Guidance in Limited Field-of-View Head-Mounted Displays
    Bork, Felix
    Schnelzer, Christian
    Eck, Ulrich
    Navab, Nassir
    IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 2018, 24 (11) : 2983 - 2992
  • [50] Optimizing Spatial Resolution in Head-Mounted Displays: Evaluating Characteristics of Peripheral Visual Field
    Harasawa, Masamitsu
    Miyashita, Yamato
    Komine, Kazuteru
    30TH ACM SYMPOSIUM ON VIRTUAL REALITY SOFTWARE AND TECHNOLOGY, VRST 2024, 2024,