Electrochemiluminescence Biosensor Based on a Duplex-Specific Nuclease and Dual-Output Toehold-Mediated Strand Displacement Cascade Amplification Strategy for Sensitive Detection of MicroRNA-499

被引:2
|
作者
Wang, Qian [1 ]
Yu, Linying [2 ]
Peng, Yao [1 ]
Sheng, Mengting [1 ]
Jin, Zhiying [2 ]
Zhang, Tingting [1 ]
Huang, Jianshe [2 ]
Yang, Xiurong [1 ,2 ]
机构
[1] Univ Sci & Technol China, Dept Chem, Hefei 230026, Anhui, Peoples R China
[2] Chinese Acad Sci, Changchun Inst Appl Chem, State Key Lab Electroanalyt Chem, Changchun 130022, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
GRAPHENE OXIDE; PLATFORM; DNAZYME; SENSOR; ASSAY;
D O I
10.1021/acs.analchem.4c02515
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The timely and accurate diagnosis of acute myocardial infarction (AMI) is of great significance to reduce mortality and morbidity associated with the condition. Herein, we developed an electrochemiluminescence (ECL) biosensor for the detection of the potential AMI biomarker microRNA-499 (miRNA-499), which was based on duplex-specific nuclease-assisted target recycling and dual-output toehold-mediated strand displacement (TMSD). First, miRNA-499 was converted into a large amount of single-stranded DNA through the DSN-assisted target recycling, which was further incubated with the DNA triple-stranded complex (S) to implement TMSD cycles. Thus, the Ru(bpy)(3)(2+)-labeled signal strands were released and captured by the capture probe on the electrode surface, resulting in an intense ECL signal. Owing to the prominent cascade signal amplification, the constructed biosensor exhibited a good linear response to miRNA-499 within the range of 100 aM-100 pM with a detection limit of 69.99 aM. Furthermore, it demonstrated superior selectivity, stability, and reproducibility. In addition, the biosensor was successfully applied to detect miRNA-499 in real human serum samples, demonstrating its potential for nucleic acid detection in the early diagnosis of diseases.
引用
收藏
页码:15624 / 15630
页数:7
相关论文
共 33 条
  • [21] Ratiometric Electrochemiluminescent/Electrochemical Strategy for Sensitive Detection of MicroRNA Based on Duplex-Specific Nuclease and Multilayer Circuit of Catalytic Hairpin Assembly
    Zhu, Liping
    Zhang, Mengqian
    Ye, Jing
    Yan, Mengxia
    Zhu, Qiuju
    Huang, Jianshe
    Yang, Xiurong
    ANALYTICAL CHEMISTRY, 2020, 92 (12) : 8614 - 8622
  • [22] Dual-Mode SERS and Electrochemical Detection of miRNA Based on Popcorn-like Gold Nanofilms and Toehold-Mediated Strand Displacement Amplification Reaction
    Zhou, Hong
    Zhang, Jishou
    Li, Binxiao
    Liu, Jing
    Xu, Jing-Juan
    Chen, Hong-Yuan
    ANALYTICAL CHEMISTRY, 2021, 93 (15) : 6120 - 6127
  • [23] Signal-off Electrochemiluminescence Biosensor Based on Phi29 DNA Polymerase Mediated Strand Displacement Amplification for MicroRNA Detection
    Chen, Anyi
    Gui, Guo-Feng
    Zhuo, Ying
    Chai, Ya-Qin
    Xiang, Yun
    Yuan, Ruo
    ANALYTICAL CHEMISTRY, 2015, 87 (12) : 6328 - 6334
  • [24] Au nanoparticles/hollow molybdenum disulfide microcubes based biosensor for microRNA-21 detection coupled with duplex-specific nuclease and enzyme signal amplification
    Shuai, Hong-Lei
    Huang, Ke-Jing
    Chen, Ying-Xu
    Fang, Lin-Xia
    Jia, Meng-Pei
    BIOSENSORS & BIOELECTRONICS, 2017, 89 : 989 - 997
  • [25] MicroRNA detection based on duplex-specific nuclease-assisted target recycling and gold nanoparticle/graphene oxide nanocomposite-mediated electrocatalytic amplification
    Han, Yuanyuan
    Qiu, Zhen
    Nawale, Ganesh N.
    Varghese, Oommen P.
    Hilborn, Jons
    Tian, Bo
    Leifer, Klaus
    BIOSENSORS & BIOELECTRONICS, 2019, 127 : 188 - 193
  • [26] Ultra-sensitive detection of microRNA-21 based on duplex-specific nuclease-assisted target recycling and horseradish peroxidase cascading signal amplification
    Peng, Weipan
    Zhao, Qian
    Piao, Jiafang
    Zhao, Miao
    Huang, Yiwen
    Zhang, Bo
    Gao, Weichen
    Zhou, Dianming
    Shu, Guiming
    Gong, Xiaoqun
    Chang, Jin
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 263 : 289 - 297
  • [27] Ratiometric Fluorescent Biosensor Based on Self-Assembled Fluorescent Gold Nanoparticles and Duplex-Specific Nuclease-Assisted Signal Amplification for Sensitive Detection of Exosomal miRNA
    Sun, Zhiwei
    Li, Juan
    Yang, Yufei
    Tong, Yao
    Li, Hui
    Wang, Chuanxin
    Du, Lutao
    Jiang, Yanyan
    BIOCONJUGATE CHEMISTRY, 2022, 33 (09) : 1698 - 1706
  • [28] Electrochemiluminescence detection of miRNA-21 based on dual signal amplification strategies: Duplex-specific nuclease-mediated target recycle and nicking endonuclease-driven 3D DNA nanomachine
    Wang, Ming-Yue
    Jing, Wen-Jie
    Wang, Li-Juan
    Jia, Li-Ping
    Ma, Rong-Na
    Zhang, Wei
    Shang, Lei
    Li, Xiao-Jian
    Xue, Qing-Wang
    Wang, Huai-Sheng
    BIOSENSORS & BIOELECTRONICS, 2023, 226
  • [29] Enzyme- and label-free electrochemical aptasensor for kanamycin detection based on double stir bar-assisted toehold-mediated strand displacement reaction for dual-signal amplification
    Hong, Feng
    Chen, Xixue
    Cao, Yuting
    Dong, Youren
    Wu, Dazhen
    Hu, Futao
    Gan, Ning
    BIOSENSORS & BIOELECTRONICS, 2018, 112 : 202 - 208
  • [30] MicroRNA-21 electrochemiluminescence biosensor based on Co-MOF-N-(4-aminobutyl)-N-ethylisoluminol/Ti3C2Tx composite and duplex-specific nuclease-assisted signal amplification
    Jiang, Yang
    Li, Rong
    He, Wenyu
    Li, Qian
    Yang, Xia
    Li, Sijia
    Bai, Wanqiao
    Li, Yan
    MICROCHIMICA ACTA, 2022, 189 (03)