Rapid simultaneous estimation of relaxation rates using multi-echo, multi-contrast MRI

被引:0
|
作者
Keeling, Elizabeth G. [1 ,2 ]
Sisco, Nicholas J. [1 ]
Mcelvogue, Molly M. [1 ]
Borazanci, Aimee [1 ]
Dortch, Richard D. [1 ]
Stokes, Ashley M. [1 ]
机构
[1] Barrow Neurol Inst, 350 W Thomas Rd, Phoenix, AZ 85013 USA
[2] Arizona State Univ, Sch Life Sci, 427 E Tyler Mall, Tempe, AZ 85281 USA
关键词
Multi-echo; Relaxation rates; Spin-and gradient-echo; Dynamic susceptibility contrast MRI (DSC-MRI); Multi-echo DSC-MRI; Spin-echo DSC-MRI; WHITE-MATTER LESIONS; SIMPLIFIED SPIN; HUMAN BRAIN; PERFUSION; REMYELINATION;
D O I
10.1016/j.mri.2024.07.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Multi-echo, multi-contrast methods are increasingly used in dynamic imaging studies to simultaneously quantify R * 2 and R 2 . To overcome the computational challenges associated with nonlinear least squares (NLSQ) fitting, we propose a generalized linear least squares (LLSQ) solution to rapidly fit R * 2 and R 2 . Methods: Spin- and gradient-echo (SAGE) data were simulated across T * 2 and T 2 values at high (200) and low (20) SNR. Full (four-parameter) and reduced (three-parameter) parameter fits were implemented and compared with both LLSQ and NLSQ fitting. Fit data were compared to ground truth using concordance correlation coefficient (CCC) and coefficient of variation (CV). In vivo SAGE perfusion data were acquired in 20 subjects with relapsingremitting multiple sclerosis. LLSQ R * 2 and R 2 , as well as cerebral blood volume (CBV), were compared with the standard NLSQ approach. Results: Across all fitting methods, T * 2 was well-fit at high (CCC = 1, CV = 0) and low (CCC >= 0.87, CV <= 0.08) SNR. Except for short T * 2 values (5 - 15 ms), T 2 was well-fit at high (CCC = 1, CV = 0) and low (CCC >= 0.99, CV <= 0.03) SNR. In vivo, LLSQ R * 2 and R 2 estimates were similar to NLSQ, and there were no differences in R * 2 across fitting methods at high SNR. However, there were some differences at low SNR and for R 2 at high and low SNR. In vivo NLSQ and LLSQ three parameter fits performed similarly, as did NLSQ and LLSQ four-parameter fits. LLSQ CBV nearly matched the standard NLSQ method for R * 2- (0.97 ratio) and R 2-CBV (0.98 ratio). Voxel-wise whole-brain fitting was faster for LLSQ (3 - 4 min) than NLSQ (16 - 18 h). Conclusions: LLSQ reliably fit for R * 2 and R 2 in simulated and in vivo data. Use of LLSQ methods reduced the computational demand, enabling rapid estimation of R * 2 and R 2 .
引用
收藏
页码:116 / 127
页数:12
相关论文
共 50 条
  • [1] A deconvolution algorithm for multi-echo functional MRI: Multi-echo Sparse Paradigm Free Mapping
    Caballero-Gaudes, Cesar
    Moia, Stefano
    Panwar, Puja
    Bandettini, Peter A.
    Gonzalez-Castillo, Javier
    [J]. NEUROIMAGE, 2019, 202
  • [2] Systematic assessment of multi-echo dynamic susceptibility contrast MRI using a digital reference object
    Stokes, Ashley M.
    Semmineh, Natenael B.
    Nespodzany, Ashley
    Bell, Laura C.
    Quarles, C. Chad
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (01) : 109 - 123
  • [3] Fast multi-contrast MRI reconstruction
    Huang, Junzhou
    Chen, Chen
    Axel, Leon
    [J]. MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1344 - 1352
  • [4] Multi-Image Reconstruction in Multi-Contrast MRI
    Ozbey, Muzaffer
    Cukur, Tolga
    [J]. 29TH IEEE CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS (SIU 2021), 2021,
  • [5] Fast Multi-contrast MRI Reconstruction
    Huang, Junzhou
    Chen, Chen
    Axel, Leon
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 281 - 288
  • [6] Synthesize High-Quality Multi-Contrast Magnetic Resonance Imaging From Multi-Echo Acquisition Using Multi-Task Deep Generative Model
    Wang, Guanhua
    Gong, Enhao
    Banerjee, Suchandrima
    Martin, Dann
    Tong, Elizabeth
    Choi, Ja
    Chen, Huijun
    Wintermark, Max
    Pauly, John M.
    Zaharchuk, Greg
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (10) : 3089 - 3099
  • [7] Multi-Image Super Resolution in Multi-Contrast MRI
    Yurt, Mahmut
    Cukur, Tolga
    [J]. 2020 28TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2020,
  • [8] A multi-contrast MRI approach to thalamus segmentation
    Corona, Veronica
    Lellmann, Jan
    Nestor, Peter
    Schoenlieb, Carola-Bibiane
    Acosta-Cabronero, Julio
    [J]. HUMAN BRAIN MAPPING, 2020, 41 (08) : 2104 - 2120
  • [9] Enhanced identification of BOLD-like components with multi-echo simultaneous multi-slice (MESMS) fMRI and multi-echo ICA
    Olafsson, Valur
    Kundu, Prantik
    Wong, Eric C.
    Bandettini, Peter A.
    Liu, Thomas T.
    [J]. NEUROIMAGE, 2015, 112 : 43 - 51
  • [10] Deep unregistered multi-contrast MRI reconstruction
    Liu, Xinwen
    Wang, Jing
    Jin, Jin
    Li, Mingyan
    Tang, Fangfang
    Crozier, Stuart
    Liu, Feng
    [J]. MAGNETIC RESONANCE IMAGING, 2021, 81 : 33 - 41