Searching for TL/OSL dose rate effects in various luminescent materials

被引:0
|
作者
Mrozik, Anna [1 ]
Bilski, Pawel [1 ]
Mandowski, Arkadiusz [2 ]
Klosowski, Mariusz [1 ]
Budzanowski, Maciej [1 ]
Drop, Jagoda [1 ]
Swakon, Jan [1 ]
Discher, Michael [3 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, Krakow, Poland
[2] Jan Dlugosz Univ, Czestochowa, Poland
[3] Univ Salzburg, Salzburg, Austria
关键词
OPTICALLY STIMULATED LUMINESCENCE; RATE DEPENDENCE; THERMOLUMINESCENCE; MODEL; OSL;
D O I
10.1016/j.radmeas.2024.107211
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The goal of the present work was to conduct an initial screening survey of several types of TL and OSL detectors, aimed at searching for the indication of the presence of dose rate effects. The study has been performed on ten different materials: LiF:Mg,Ti; LiF:Mg,Cu,P; CaF2:Dy; 2 :Dy; Al-P glass; YAP:Mn; CaSO4:Dy; 4 :Dy; Al2O3:C; 2 O 3 :C; BeO; MgB4O7: 4 O 7 : Ce.Li and quartz. Gamma-ray dose rates ranged from 0.1 mGy/h to 90 Gy/h. No clear evidence of dose rate effects was found for any material. In two cases (MgB4O7: 4 O 7 : Ce,Li and BeO) some irregularities of the response were observed, which require further investigations but most probably they are not attributable to the dose rate influence.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Calculation of relative luminescent efficiency of TL/OSL detectors to cosmic radiation spectrum in cis-lunar space
    Bilski, P.
    Matthia, D.
    Berger, T.
    Gaza, R.
    RADIATION MEASUREMENTS, 2024, 177
  • [22] Gaussian approximation of thermoluminescence (TL) peaks: A common misconception for analysis of TL of persistent luminescent materials
    Chandrasekhar, Ngangbam
    Gartia, K.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 745 : 773 - 778
  • [23] Polynomial expressions of electron depth dose as a function of energy in various materials: application to thermoluminescence (TL) dosimetry
    Deogracias, EC
    Wood, JL
    Wagner, EC
    Kearfott, KJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 629 - 637
  • [24] TL and OSL dose response and stability properties of various commercially glass samples obtained from Turkey for dosimetric purposes in the UV emission spectral region
    Sahiner, Eren
    APPLIED RADIATION AND ISOTOPES, 2017, 128 : 68 - 74
  • [25] Component resolved OSL dose response and sensitization of various sedimentary quartz samples
    Kiyak, N. G.
    Polymeris, G. S.
    Kitis, G.
    RADIATION MEASUREMENTS, 2007, 42 (02) : 144 - 155
  • [26] A comparative study of the anomalous fading effects of TL and OSL signals of Durango apatite
    Polymeris, GS
    Tsirliganis, N
    Loukou, Z
    Kitis, G
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2006, 203 (03): : 578 - 590
  • [27] Dose rate effects on the performance of MWCVD diamond films as TL gamma radiation dosimeter
    Cruz-Zaragoza, E.
    Gastelum, S.
    Melendrez, R.
    Chernov, V.
    Barboza-Flores, M.
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2010, 207 (08): : 1944 - 1948
  • [28] Dose and dose rate dependence of time-resolved OSL from Korean paleosol quartz
    Kim, M. J.
    Choi, J. H.
    Hong, D. G.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1518 - 1521
  • [30] The use of TL and OSL emissions of 3Al2O3-2SiO2:Er,Yb phosphors for dose rate estimation
    Goncalves, Katia Alessandra
    Tatumi, Sonia Hatsue
    Rocca, Rene Rojas
    Ventieri, Alexandre
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2015, 306 (03) : 775 - 780