Development and test of the laser blow-off impurity injection system in experimental advanced superconducting tokamak

被引:0
|
作者
Shen, Y. C. [1 ]
Fan, Y. [2 ,3 ]
Zhang, H. M. [2 ]
Lyu, B. [2 ,4 ]
Lin, Z. C. [2 ,4 ]
Yin, X. H. [3 ]
Wang, F. D. [2 ]
Fu, J. [2 ]
Ji, H. J. [2 ,4 ]
Zeng, C. [2 ,3 ]
Sun, B. [2 ,3 ]
Mao, L. Y. [2 ,3 ]
机构
[1] Hefei Normal Univ, Sch Phys & Mat Engn, Hefei 230601, Peoples R China
[2] Chinese Acad Sci, Inst Plasma Phys, Hefei Inst Phys Sci, Hefei 230031, Peoples R China
[3] Univ South China, Sch Elect Engn, Hengyang 421001, Peoples R China
[4] Univ Sci & Technol China, Grad Sch, Sci Isl Branch, Hefei 230031, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 08期
基金
中国国家自然科学基金;
关键词
TRANSPORT;
D O I
10.1063/5.0215727
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Laser Blow-Off (LBO) impurity injection system is a crucial tool for studying impurity transport and plasma behavior. Conducting proactive impurity transport research is challenging on experimental advanced superconducting tokamak (EAST) due to the uncontrollable generation of impurity sources; therefore, it is necessary to develop a laser blow-off impurity injection system for injecting controlled trace impurity particles. This study presents the design and test results of an LBO system for the EAST. The system aims to provide precise and repeatable control over the timing and quantity of impurity injection. The system primarily consists of a laser source, two mirrors, a moveable focusing lens, a target material, and a vacuum system. The movement of the focusing lens is achieved by a three-dimensional displacement system. The operation of the system is completed by a remote control system. With the accurate control system, the laser spot diameter is adjustable, allowing for modification of impurity injection quantity. The test results demonstrate that the system can rapidly detect external trigger signals and ensure precise timing for the impurity injection. Furthermore, this system can also quickly change the focal point of the laser spot, addressing the requirements for impurity injections during the experiments with less than 0.4 mm position error for laser spot focusing. Test results have shown that the aluminum film material can be peeled off by the LBO system when the laser energy exceeds 650 mJ and the smallest ablation spot is about 1 mm. This study is of significant importance for conducting plasma impurity transport research on the EAST.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Overview of diagnostic system in the experimental advanced superconducting tokamak
    Gao, X.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2008, 51 (02) : 246 - 250
  • [22] Investigation of impurity transport using laser blow-off technique in the HL-2A Ohmic and ECRH plasmas
    张凯
    崔正英
    孙平
    董春凤
    邓玮
    董云波
    宋绍栋
    蒋敏
    李永高
    卢平
    杨青巍
    Chinese Physics B, 2016, (06) : 300 - 308
  • [23] Investigation of impurity transport using laser blow-off technique in the HL-2A Ohmic and ECRH plasmas
    Zhang, Kai
    Cui, Zheng-Ying
    Sun, Ping
    Dong, Chun-Feng
    Deng, Wei
    Dong, Yun-Bo
    Song, Shao-Dong
    Jiang, Min
    Li, Yong-Gao
    Lu, Ping
    Yang, Qing-Wei
    CHINESE PHYSICS B, 2016, 25 (06)
  • [24] DEVELOPMENT OF IN SITU LASER BLOW OFF CLEANING SETUP FOR ADITYA TOKAMAK WINDOW
    Kumar, S. Sasanka
    Jayaraj, M. K.
    Kumar, Ajai
    Kumar, Ravi A. V.
    FUSION SCIENCE AND TECHNOLOGY, 2013, 64 (01) : 54 - 62
  • [25] Development of precision measurement network of experimental advanced superconducting tokamak
    Yu, Liandong
    Zhao, Huining
    Zhang, Wei
    Li, Weishi
    Deng, Huaxia
    Song, Yuntao
    Gu, Yongqi
    OPTICAL ENGINEERING, 2014, 53 (12)
  • [26] Space-resolved extreme ultraviolet spectrometer system for impurity behavior research on experimental advanced superconducting Tokamak
    Shen, Y.
    Du, X.
    Zhang, W.
    Wang, Q.
    Li, Y.
    Fu, J.
    Wang, F.
    Xu, J.
    Lu, B.
    Shi, Y.
    Wan, B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 700 : 86 - 90
  • [27] Impurity Behavior in Plasma Recovery after a Vacuum Failure in the Experimental Advanced Superconducting Tokamak
    Zhao, Zihang
    Zhang, Ling
    Zhou, Ruijie
    Yang, Yang
    Zhang, Wenmin
    Cheng, Yunxin
    Morita, Shigeru
    Ti, Ang
    Hu, Ailan
    Sun, Zhen
    Zhang, Fengling
    Zhao, Weikuan
    Li, Zhengwei
    Cao, Yiming
    Zuo, Guizhong
    Liu, Haiqing
    APPLIED SCIENCES-BASEL, 2023, 13 (07):
  • [28] Filterscope diagnostic system on the Experimental Advanced Superconducting Tokamak (EAST)
    Xu, Z.
    Wu, Z. W.
    Gao, W.
    Chen, Y. J.
    Wu, C. R.
    Zhang, L.
    Huang, J.
    Chang, J. F.
    Yao, X. J.
    Gao, W.
    Zhang, P. F.
    Jin, Z.
    Hou, Y. M.
    Guo, H. Y.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (11):
  • [29] Microwave Doppler reflectometer system in the Experimental Advanced Superconducting Tokamak
    Zhou, C.
    Liu, A. D.
    Zhang, X. H.
    Hu, J. Q.
    Wang, M. Y.
    Li, H.
    Lan, T.
    Xie, J. L.
    Sun, X.
    Ding, W. X.
    Liu, W. D.
    Yu, C. X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2013, 84 (10):
  • [30] Halo current diagnostic system of experimental advanced superconducting tokamak
    Chen, D. L.
    Shen, B.
    Granetz, R. S.
    Sun, Y.
    Qian, J. P.
    Wang, Y.
    Xiao, B. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (10):