Experimental and numerical research on seismic behavior of end-plate connection beam-column joints considering concrete floor effect

被引:0
|
作者
Lu, Shengcan [1 ]
Zhang, Jiong [1 ]
Wang, Minrong [1 ]
Chen, Huiquan [1 ]
机构
[1] Wuyi Univ, Sch Civil Engn & Architecture, Jiangmen 529020, Peoples R China
关键词
End-plate connection; Ductility; Hysteresis response; Concrete floor; COMPOSITE JOINTS; STEEL; PERFORMANCE; DESIGN;
D O I
10.1016/j.istruc.2024.106770
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
With the aims to study the seismic performance of the end-plate connection (EPC) joint with concrete floor, four full-scale specimens with different configuration (two specimens in major direction, and the other in minor direction) of the pseudo-static cyclic loading tests were conducted. Based on the failure criteria, the mechanical behaviors and failure modes of the specimens were investigated, including major and minor connection directions. The hysteresis response, bearing capacity, stiffness evaluation, and energy dissipation of the specimens were evaluated, and with a average ductility coefficient value of all specimens is about gamma = 4.0. Meanwhile, to analyze and verify the accuracy of experimental results, the nonlinear models of the specimens were performed in ABAQUS software. In addition, a series of parametric analysis were performed to study the influence of axial compression ratios, thickness ratios (the ratio(eta 1) 1 ) of end-plate thickness to column flange thickness, and the ratio (eta 2), 2 ), of end-plate thickness to column web thickness), and concrete compressive strength on the joint seismic performance. This parametric analysis result indicates that increasing the thickness ratio and concrete compressive strength reasonably can effectively improve the seismic behavior of the overall joint with the concrete floor, especially in minor direction joints.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Seismic behavior of a type of welded precast concrete beam-column connection
    Rodriguez, Mario E.
    Torres-Matos, Miguel
    PCI JOURNAL, 2013, : 81 - 94
  • [22] Seismic behavior of a type of welded precast concrete beam-column connection
    Rodríguez, Mario E.
    Torres-Matos, Miguel
    PCI Journal, 2013, 58 (03): : 81 - 94
  • [23] Seismic Behavior of Reinforced Concrete Exterior Wide Beam-Column Joints
    Li, Bing
    Kulkarni, Sudhakar A.
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (01): : 26 - 36
  • [24] Experimental and Numerical Studies on the Seismic Performance of New Assembled Concrete Frame Beam-Column Joints
    Liu, Jianhua
    Liu, Yunlin
    Yu, Dehu
    BUILDINGS, 2023, 13 (02)
  • [25] Seismic behavior of beam-column joints with different concrete compressive strengths
    Choi, Seung-Ho
    Kim, Jae-Hyun
    Jeong, Hoseong
    Kim, Kang Su
    JOURNAL OF BUILDING ENGINEERING, 2022, 52
  • [26] Size effect and strain rate effect on seismic behavior of reinforced concrete beam-column joints
    Jin, Liu
    Wan, Shunyin
    Li, Dong
    Du, Xiuli
    STRUCTURAL CONCRETE, 2022, 23 (03) : 1453 - 1468
  • [27] Experimental and numerical studies on seismic behaviour of exterior beam-column joints
    Asha, P.
    Sundararajan, R.
    COMPUTERS AND CONCRETE, 2014, 13 (02): : 221 - 234
  • [28] Numerical Modelling of Seismic Behavior of Retrofitted RC Beam-Column Joints
    Arjmandi, Seyyed Aliasghar
    Yousefi, Maryam
    CIVIL ENGINEERING JOURNAL-TEHRAN, 2018, 4 (07): : 1728 - 1737
  • [29] Experimental study on seismic behavior of outer end-plate reinforced connection
    Bu Y.
    Zhang D.
    Yan L.
    Niu D.
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2019, 47 (08): : 65 - 70
  • [30] Experimental study on deformation behavior of precast steel reinforced concrete beam-column joints with beam-beam connection
    Guan M.
    Liang Z.
    Zeng Q.
    Zhang Y.
    Wang G.
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2022, 55 : 9 - 15