Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®

被引:0
|
作者
Mihalinec, Katja [1 ]
Martinez-Cepa, Carmen B. [2 ]
Zuil-Escobar, Juan C. [2 ]
Kejzar, Natasa [3 ]
Vauhnik, Renata [1 ,4 ]
机构
[1] Univ Ljubljana, Fac Hlth Sci, Dept Physiotherapy, Biomech Lab, Zdravstvena Pot 5, Ljubljana 1000, Slovenia
[2] CEU Univ, Univ San Pablo CEU, Fac Med, Dept Fisioterapia,Urbanizac Monteprincipe, Boadilla Del Monte, Spain
[3] Univ Ljubljana, Inst Biostat & Med Informat, Fac Med, Ljubljana, Slovenia
[4] Arthron, Inst Joint & Sports Injuries, Ukmarjeva 2, Ljubljana, Slovenia
关键词
anterior laxity; arthrometry; rotational laxity; reliability; ANTERIOR CRUCIATE LIGAMENT; ROTATIONAL KNEE LAXITY; IN-VIVO; VARUS-VALGUS; HEALTHY; INJURIES;
D O I
10.1002/jeo2.70026
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeThe purpose of our study was to test the intra-rater and inter-rater reliability of the DYNEELAX (R) arthrometer in healthy subjects. Since rotational laxity will be measured for the first time in humans, indications for normative values will also be presented.MethodsKnee anterior laxity and rotational laxity using a DYNEELAX (R) arthrometer were assessed in 73 subjects (39 females and 34 males). An intraclass correlation coefficient was calculated to evaluate the intra-rater and inter-rater reliability of the DYNEELAX (R).ResultsAn intraclass correlation coefficient for intra-rater reliability ranges from 0.631 (95% confidence interval; [CI]: 0.47-0.75) to 0.699 (95% CI: 0.56-0.80) and from 0.916 (95% CI: 0.87-0.95) to 0.94 (95% CI: 0.91-0.96) for anterior knee laxity and rotational knee laxity, respectively. An intraclass correlation coefficient for inter-rater reliability ranges from 0.578 (95% CI: 0.40-0.71) to 0.646 (95% CI: 0.44-0.78) and from 0.822 (95% CI: 0.57-0.91) to 0.933 (95% CI: 0.89-0.96) for anterior knee laxity and rotational knee laxity, respectively.ConclusionsThe DYNEELAX (R) arthrometer has good to excellent intra-rater and inter-rater reliability for rotational knee laxity and moderate intra-rater reliability for anterior knee laxity in healthy subjects. Future studies should investigate the clinical significance of anterior and rotational laxity measured with the DYNEELAX (R) arthrometer in patients with knee pathology, as both laxities are critical for assessing the integrity of the intra-articular structures of the knee in clinical practice.Level of evidenceLevel IV.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Inter-rater and intra-rater reliability of a clinical protocol for measuring turnout in collegiate dancers
    Greene, Amanda
    Lasner, Andrea
    Deu, Rajwinder
    Oliphant, Seth
    Johnson, Kenneth
    PHYSIOTHERAPY THEORY AND PRACTICE, 2019, 35 (01) : 94 - 99
  • [22] Inter-rater and Intra-rater Reliability of a Mobile App Method to Measure Lumbar Lordosis
    Gnanasigamani, Jency Thangasheela
    Ramalingam, Vinodhkumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [23] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [24] Inter-Rater and Intra-Rater Reliability of the Bahasa Melayu Version of Rose Angina Questionnaire
    Hassan, N. B.
    Choudhury, S. R.
    Naing, L.
    Conroy, R. M.
    Rahman, A. R. A.
    ASIA-PACIFIC JOURNAL OF PUBLIC HEALTH, 2007, 19 (03) : 45 - 51
  • [25] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [26] Intra-rater and inter-rater reliability of the rapid entire body assessment (REBA) tool
    Schwartz, Adam H.
    Albin, Thomas J.
    Gerberich, Susan G.
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2019, 71 : 111 - 116
  • [27] Intra-rater and inter-rater reliability of the standardized ultrasound protocol for assessing subacromial structures
    Hougs Kjaer, Birgitte
    Ellegaard, Karen
    Wieland, Ina
    Warming, Susan
    Juul-Kristensen, Birgit
    PHYSIOTHERAPY THEORY AND PRACTICE, 2017, 33 (05) : 398 - 409
  • [28] An evaluation of the inter-rater and intra-rater reliability of OccuPro's functional capacity evalution
    Scheel, Carrie
    Mecham, Jim
    Zuccarello, Vic
    Mattes, Ryan
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2018, 60 (03): : 465 - 473
  • [29] INTER-RATER AND INTRA-RATER AGREEMENT OF THE REHABILITATION ACTIVITIES PROFILE
    JELLES, F
    VANBENNEKOM, CAM
    LANKHORST, GJ
    SIBBEL, CJP
    BOUTER, LM
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1995, 48 (03) : 407 - 416
  • [30] INTER-RATER, INTRA-RATER, AND INTER-MACHINE RELIABILITY OF QUANTITATIVE ULTRASOUND MEASUREMENTS OF THE PATELLAR TENDON
    Gellhorn, Alfred C.
    Carlson, M. Jake
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2013, 39 (05): : 791 - 796