A Flexible Control Strategy for Multi-Functional PV Inverters with Load Compensation Capabilities Considering Current Limitations and Unbalanced Load Conditions

被引:0
|
作者
Osorio, Fausto [1 ]
Mantilla, Maria A. [1 ]
Rey, Juan M. [1 ]
Petit, Johann F. [1 ]
机构
[1] Univ Ind Santander, Escuela Ingn Electr Elect & Telecomunicac, Bucaramanga 680002, Colombia
关键词
photovoltaic inverters; power quality; control algorithms; reactive power compensation; unbalanced loads; load compensation; POWER; OPERATION;
D O I
10.3390/en17174218
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Multi-functional photovoltaic (PV) inverters incorporate ancillary services to enhance power quality and mitigate stability issues in distribution networks. These next-generation PV inverters will achieve a higher utilization of the inverter's rated capacity, improving the cost-effectiveness of PV technology. However, the power required to perform ancillary services, such as load compensation capabilities, could exceed the inverter's capacity, risking the components' integrity. Therefore, multi-functional control algorithms must limit the power capacity according to the system's nominal currents. Despite this, most control proposals do not address this issue when load balancing capabilities are included for PV inverter control. This paper proposes a flexible control strategy for three-phase multi-functional PV inverters, considering load balancing functionalities while keeping the inverter currents within safe operating limits. The proposal introduces two control parameters whose variation results in different load compensation capabilities. These parameters can be adapted dynamically according to the inverter rated capacity not used for active power injection and the load compensation requirements. Additionally, a control algorithm is proposed to limit the inverter current according to the nominal values supported by the device. This algorithm also allows setting compensation objectives following a priority scheme in which the injection of the PV active power is prioritized over the load compensation functionalities. Reactive power compensation and load balancing functionalities are also considered at a lower level of hierarchical priority. The proposal was evaluated through experimental tests on a multi-functional PV inverter prototype under various operational conditions. The experimental results show an excellent control strategy performance, achieving the control objectives under unbalanced load conditions.
引用
下载
收藏
页数:24
相关论文
共 50 条
  • [31] An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
    Naderipour, Amirreza
    Zin, Abdullah Asuhaimi Mohd
    Bin Habibuddin, Mohd Hafiz
    Miveh, Mohammad Reza
    Guerrero, Josep M.
    PLOS ONE, 2017, 12 (02):
  • [32] Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults
    Afshari, Ehsan
    Moradi, Gholam Reza
    Rahimi, Ramin
    Farhangi, Babak
    Yang, Yongheng
    Blaabjerg, Frede
    Farhangi, Shahrokh
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (11) : 8908 - 8918
  • [33] A novel control strategy for load converter of DC isolated distribution system under unbalanced loading conditions
    Noroozian, R.
    Abedi, M.
    Gharehpetian, G. B.
    Hosseini, S. H.
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2009, 10 (06): : 890 - 899
  • [34] Improved Voltage Harmonics Compensation Strategy for a Stand-Alone DFIG Operating under Unbalanced and Nonlinear Load Conditions
    Abdoune K.
    Abdoune F.
    Aouzellag D.
    Ghedamsi K.
    Periodica polytechnica Electrical engineering and computer science, 2020, 64 (02): : 144 - 156
  • [35] A novel control strategy for load converter of DC isolated distribution system under unbalanced loading conditions
    R.NOROOZIAN
    M.ABEDI
    G.B.GHAREHPETIAN
    S.H.HOSSEINI
    Journal of Zhejiang University-Science A(Applied Physics & Engineering), 2009, 10 (06) : 890 - 899
  • [36] A novel control strategy for load converter of DC isolated distribution system under unbalanced loading conditions
    R. Noroozian
    M. Abedi
    G. B. Gharehpetian
    S. H. Hosseini
    Journal of Zhejiang University-SCIENCE A, 2009, 10 : 890 - 899
  • [37] Multi-Time Scale Optimal Control of Voltage Fluctuation at PV Grids Considering Load Changes
    Yangrui Zhang
    Yakui Zhu
    Chao Zhang
    Bingyu Zhang
    Hongying Wang
    Yajie Zhang
    Journal of Electrical Engineering & Technology, 2025, 20 (3) : 1283 - 1291
  • [38] A Novel Control Strategy for Shunt Active Power Filter under Nonlinear and Unbalanced Three Phase Load Conditions
    Hao, Shuai
    Fu, Zhouxing
    Wang, Qingliang
    Zheng, Jie
    Zhang, Minglu
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 96 - 98
  • [39] Multi-source coordinated scheduling strategy of wind power-PV-CSP considering high energy load
    Zhang X.
    Xiong W.
    Wang K.
    Wang X.
    Chen W.
    International Journal of Modelling, Identification and Control, 2020, 34 (02): : 116 - 126
  • [40] Multi-source coordinated scheduling strategy of wind power-PV-CSP considering high energy load
    Zhang, Xiaoying
    Xiong, Wei
    Wang, Kun
    Wang, Xiaolan
    Chen, Wei
    INTERNATIONAL JOURNAL OF MODELLING IDENTIFICATION AND CONTROL, 2020, 34 (02) : 116 - 126