Sensitivity Enhancement of Franckeite-Based Surface Plasmon Resonance Sensors Using A Bimetallic Structure

被引:0
|
作者
Kumar, Rajeev [1 ]
Singh, Shivam [2 ]
Sarkar, Partha [3 ]
Garia, Lalit [4 ]
Kakar, Varun Kumar [4 ]
Alsubaie, Abdullah Saad [5 ]
Pal, Amrindra [6 ]
机构
[1] Graph Era Deemed Be Univ, Dept Elect & Commun Engn, Dehra Dun 248001, Uttarakhand, India
[2] ABES Engn Coll, Dept Elect & Commun Engn, Ghaziabad 201009, Uttar Pradesh, India
[3] Natl Inst Technol, Dept Elect & Commun Engn, Mahatma Gandhi Rd, Durgapur 713209, West Bengal, India
[4] BT Kumaon Inst Technol, Dept Elect & Commun Engn, Dwarahat 263653, Uttarakhand, India
[5] Taif Univ, Coll Khurma Univ Coll, Dept Phys, Taif 21944, Saudi Arabia
[6] Chandigarh Univ, Univ Ctr Res & Dev, Dept ECE, Mohali 140413, India
关键词
Surface plasmon resonance; Sensitivity; Detection accuracy; Franckeite; Penetration depth; SPR SENSOR; HETEROSTRUCTURE; BIOSENSOR; MXENE;
D O I
10.1007/s11468-024-02432-z
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study proposes the franckeite layer onto a bimetallic (Au-Cu) based sensor. The proposed sensors use CaF2 prism, Au (39 nm), Cu (5 nm), with/without franckeite, and adsorption layer (sensing medium (SM). All the performance analysis is carried out at 633 nm wavelength. At optimized, the bimetallic layer, the remarkable sensitivity, DA, and FoM of 350.76 degrees/RIU, 0.144/degrees, and 50.50/RIU are achieved, respectively. The proposed sensor's computed electric field (EF) intensity and penetration depth (PD) are 2.11 x 105 V/m and 204.28 nm at an RI of 1.330 SM. With a quick response indicated by a significant shift in resonance angle, the suggested structure would help detect the RI between 1.33 and 1.335. A detailed comparison with the most recent publications in biomedical applications confirms the outstanding performance of the proposed SPR sensors. This comparison highlights the significant potential of the sensors in biosensing and biomedicine.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Affinity-Based Nanoarchitectured Biotransducer for Sensitivity Enhancement of Surface Plasmon Resonance Sensors for In Vitro Diagnosis: A Review
    Nangare, Sopan N.
    Patil, Pravin O.
    [J]. ACS BIOMATERIALS SCIENCE & ENGINEERING, 2021, 7 (01): : 2 - 30
  • [32] On the sensitivity of surface plasmon resonance sensors with spectral interrogation
    Homola, J
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 41 (1-3) : 207 - 211
  • [33] Sensitivity enhancement of a surface plasmon resonance based biomolecules sensor using graphene and silicon layers
    Verma, Roli
    Gupta, Banshi D.
    Jha, Rajan
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 160 (01) : 623 - 631
  • [34] Figure of merit enhancement of surface plasmon resonance sensors using absentee layer
    Chen, Zhaoyang
    Zhao, Xin
    Lin, Chengyou
    Chen, Shujing
    Yin, Liang
    Ding, Yingchun
    [J]. APPLIED OPTICS, 2016, 55 (25) : 6832 - 6835
  • [35] The performance enhancement of surface plasmon resonance optical sensors using nanomaterials: A review
    Philip, Abin
    Kumar, A. Ruban
    [J]. COORDINATION CHEMISTRY REVIEWS, 2022, 458
  • [36] Electric field enhancement in surface plasmon resonance bimetallic configuration based on chalcogenide prism
    Maharana, Pradeep Kumar
    Bharadwaj, Sriram
    Jha, Rajan
    [J]. JOURNAL OF APPLIED PHYSICS, 2013, 114 (01)
  • [37] Sensitivity Enhancement for Surface Plasmon Resonance Imaging Biosensor by Utilizing Gold–Silver Bimetallic Film Configuration
    Liangping Xia
    Shaoyun Yin
    Hongtao Gao
    Qiling Deng
    Chunlei Du
    [J]. Plasmonics, 2011, 6 : 245 - 250
  • [38] Development of a Surface-Plasmon Resonance Sensor Testbed for Bimetallic Sensors
    Babu, Roshni S.
    Colenso, Hamish R.
    Gouws, Gideon J.
    Auguie, Baptiste
    Moore, Ciaran P.
    [J]. 2019 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2019, : 927 - 932
  • [39] Tuning and sensitivity enhancement of surface plasmon resonance sensor
    Gupta, Gaurav
    Kondoh, Jun
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2007, 122 (02) : 381 - 388
  • [40] Sensitivity enhancement of a graphene-barium titanate-based surface plasmon resonance biosensor with an Ag-Au bimetallic structure in the visible region
    Liu, Lili
    Wang, Mei
    Jiao, Lipeng
    Wu, Ting
    Xia, Feng
    Liu, Meijie
    Kong, Weijin
    Dong, Lifeng
    Yun, Maojin
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2019, 36 (04) : 1108 - 1116