Visualization experimental study on evaporation heat transfer characteristics of an open evaporator with a tower-like porous wick

被引:0
|
作者
Wang, Dongdong [1 ]
Fang, Weizhen [1 ]
Chen, Ling [1 ]
Ding, Shilei [1 ]
Lin, Qi [1 ]
Chu, Huaqiang [1 ]
机构
[1] Anhui Univ Technol, Sch Energy & Environm, Maanshan 243002, Peoples R China
基金
中国国家自然科学基金;
关键词
Tower-like porous wick; Visualization; Temperature overshoot; Performance deterioration; PIPE; PERFORMANCE;
D O I
10.1016/j.ijheatfluidflow.2024.109489
中图分类号
O414.1 [热力学];
学科分类号
摘要
Temperature overshoot often occurs in loop heat pipe, which is caused by the large bubble in the compensation chamber. But it is still uncertain whether this large bubble grew from parasitic bubbles inside porous wick. A multi-layer tower-like porous wick is designed to understand the growth and expansion of parasitic bubbles. The parasitic bubbles are induced to occur inside porous wick by inserting a copper pillar on the evaporator wall, and the multi-layer porous wick is used to eliminate parasitic bubbles. The pumping stagnation occurs under certain heat loads, but temperature overshoot of the evaporator wall no longer occurs in the open evaporator with the tower-like porous wick, which guides the design of evaporator to avoid temperature overshoot. It is found that a lot of small bubbles only appears on the lower surface of porous wick immersed in liquid in the evaporator, while not appears on the upper surface. Three groups of repeated experiments are carried out sequentially and the performance of the evaporation heat transfer gradually deteriorates, which is speculated to be caused by a gap between porous wick and the copper pillar, larger pore size next to copper pillar, or poor wetting caused by copper pillar oxidation. Two different types of the evaporator overheating are discovered, including the overall retreat of the evaporating interface and dry -out region expanded from the internal of porous wick to the external. At high heat load, the evaporating interface expands along the copper pillar, causing an increase in the heat transfer coefficient of the evaporator. The research results indicate that in order to better utilize porous wick for evaporation heat transfer, it is necessary to reliably adhere porous wick to the heating surface and avoid the formation of the large bubble in the compensation chamber.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Flow and heat transfer characteristics in the porous wick condenser of CPL
    曲艺
    彭晓峰
    刘涛
    Science in China(Series E:Technological Sciences), 2001, (05) : 499 - 506
  • [22] Heat and mass transfer characteristics of alkali metal working medium in porous wick evaporator based on capillary pumped loop
    Wu S.
    Zheng X.
    Xiao L.
    1600, Beijing University of Aeronautics and Astronautics (BUAA) (32): : 2934 - 2940
  • [23] Experimental study on the heat transfer characteristics in falling liquid film evaporator
    Shi, Mingheng
    Prichard, C.
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 1997, 18 (01): : 77 - 80
  • [24] Flow and heat transfer characteristics in the porous wick condenser of CPL
    Qu, Y
    Peng, XF
    Liu, T
    SCIENCE IN CHINA SERIES E-TECHNOLOGICAL SCIENCES, 2001, 44 (05): : 499 - 506
  • [25] Flow and heat transfer characteristics in the porous wick condenser of CPL
    Yi Qu
    Xiaofeng Peng
    Tao Liu
    Science in China Series E: Technological Sciences, 2001, 44 : 499 - 506
  • [26] Experimental study on heat transfer characteristics evaporation of circulatory flash
    Zhang, Yousen
    Wang, Jinshi
    Liu, Jiping
    Chong, Daotong
    Zhang, Wei
    Yan, Junjie
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 67 : 836 - 842
  • [27] Flow and heat transfer analysis in porous wick of CPL evaporator based on field synergy principle
    Z. C. Liu
    W. Liu
    A. Nakayama
    Heat and Mass Transfer, 2007, 43 : 1273 - 1281
  • [28] Flow and heat transfer analysis in porous wick of CPL evaporator based on field synergy principle
    College of Energy and Power Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
    Kung Cheng Je Wu Li Hsueh Pao, 2006, 2 (295-297):
  • [29] Flow and heat transfer analysis in porous wick of CPL evaporator based on field synergy principle
    Liu, Z. C.
    Liu, W.
    Nakayama, A.
    HEAT AND MASS TRANSFER, 2007, 43 (12) : 1273 - 1281
  • [30] Experimental study on loop heat pipe with two-wick flat evaporator
    Liu, Zhichun
    Wang, Dongdong
    Jiang, Chi
    Yang, Jinguo
    Liu, Wei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2015, 94 : 9 - 17