Visualization experimental study on evaporation heat transfer characteristics of an open evaporator with a tower-like porous wick

被引:0
|
作者
Wang, Dongdong [1 ]
Fang, Weizhen [1 ]
Chen, Ling [1 ]
Ding, Shilei [1 ]
Lin, Qi [1 ]
Chu, Huaqiang [1 ]
机构
[1] Anhui Univ Technol, Sch Energy & Environm, Maanshan 243002, Peoples R China
基金
中国国家自然科学基金;
关键词
Tower-like porous wick; Visualization; Temperature overshoot; Performance deterioration; PIPE; PERFORMANCE;
D O I
10.1016/j.ijheatfluidflow.2024.109489
中图分类号
O414.1 [热力学];
学科分类号
摘要
Temperature overshoot often occurs in loop heat pipe, which is caused by the large bubble in the compensation chamber. But it is still uncertain whether this large bubble grew from parasitic bubbles inside porous wick. A multi-layer tower-like porous wick is designed to understand the growth and expansion of parasitic bubbles. The parasitic bubbles are induced to occur inside porous wick by inserting a copper pillar on the evaporator wall, and the multi-layer porous wick is used to eliminate parasitic bubbles. The pumping stagnation occurs under certain heat loads, but temperature overshoot of the evaporator wall no longer occurs in the open evaporator with the tower-like porous wick, which guides the design of evaporator to avoid temperature overshoot. It is found that a lot of small bubbles only appears on the lower surface of porous wick immersed in liquid in the evaporator, while not appears on the upper surface. Three groups of repeated experiments are carried out sequentially and the performance of the evaporation heat transfer gradually deteriorates, which is speculated to be caused by a gap between porous wick and the copper pillar, larger pore size next to copper pillar, or poor wetting caused by copper pillar oxidation. Two different types of the evaporator overheating are discovered, including the overall retreat of the evaporating interface and dry -out region expanded from the internal of porous wick to the external. At high heat load, the evaporating interface expands along the copper pillar, causing an increase in the heat transfer coefficient of the evaporator. The research results indicate that in order to better utilize porous wick for evaporation heat transfer, it is necessary to reliably adhere porous wick to the heating surface and avoid the formation of the large bubble in the compensation chamber.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Evaporation heat transfer characteristic of porous wick in an open capillary evaporator
    Wang, Dongdong
    Wang, Jinxin
    Liu, Pengjie
    Ding, Shilei
    Chu, Huaqiang
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2020, 155
  • [2] Parametric study on flow and heat transfer characteristics of porous wick evaporator based on AMTEC
    Wu, Shuang-Ying
    Cao, Bao-Xi
    Xiao, Lan
    Li, You-Rong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2012, 26 (03) : 973 - 981
  • [3] Parametric study on flow and heat transfer characteristics of porous wick evaporator based on AMTEC
    Shuang-Ying Wu
    Bao-Xi Cao
    Lan Xiao
    You-Rong Li
    Journal of Mechanical Science and Technology, 2012, 26 : 973 - 981
  • [4] Experimental study on evaporation heat transfer characteristics of multi-composite porous wick with three different powders
    Wang, Dongdong
    Fang, Weizhen
    Chen, Ling
    Zhang, Lu
    Chu, Huaqiang
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [5] The analysis of heat and mass transfer for the porous wick in the CPL evaporator
    Huang, XM
    Liu, W
    Liu, ZC
    Han, YM
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 809 - 815
  • [6] A Mathematical Model to Analyze Heat and Mass Transfer Characteristics of a CPL Evaporator Porous Wick
    Huang, X.
    Liu, W.
    HEAT TRANSFER-ASIAN RESEARCH, 2005, 34 (04): : 209 - 218
  • [7] Experimental studies on boiling heat transfer and friction characteristics in evaporator with double-layer micro/nano porous wick
    Cheng, Yongpan
    Wang, Jinxin
    Yuan, Jindou
    Xu, Jinliang
    APPLIED THERMAL ENGINEERING, 2023, 221
  • [8] Simulation of flow and heat transfer with evaporation in a porous wick of a CPL evaporator on pore scale by lattice Boltzmann method
    Li, Q.
    Zhao, K.
    Xuan, Y. M.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (13-14) : 2890 - 2901
  • [9] Evaporation heat transfer characteristics of composite porous wick with spherical-dendritic powders
    Wang, Dongdong
    Wang, Jinxin
    Bao, Xiangjun
    Chen, Guang
    Chu, Huaqiang
    APPLIED THERMAL ENGINEERING, 2019, 152 : 825 - 834
  • [10] The numerical simulation of the flow and heat transfer for the porous wick in CPL evaporator
    Liu, ZC
    Liu, W
    Han, YM
    Huang, XM
    PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON HEAT TRANSFER ENHANCEMENT AND ENERGY CONSERVATION, VOLS 1 AND 2, 2004, : 833 - 838