Research on Structural Design and Optimisation Analysis of a Downhole Multi-Parameter Real-Time Monitoring System for Intelligent Well Completion

被引:0
|
作者
Bi, Gang [1 ,2 ]
Fu, Shuaishuai [1 ]
Wang, Jinlong [3 ]
Wu, Jiemin [4 ]
Yuan, Peijie [1 ]
Peng, Xianbo [1 ]
Wang, Min [5 ]
Gong, Yongfeng [6 ]
机构
[1] Xian Shiyou Univ, Coll Petr Engn, Xian 710065, Peoples R China
[2] Xian Shiyou Univ, Shaanxi Key Lab Well Stabil & Fluid & Rock Mech Oi, Xian 710065, Peoples R China
[3] China Oilfield Serv Ltd, Integrated Solut & New Energy, Tianjin 300459, Peoples R China
[4] Shaanxi Yanchang Petr Grp Co Ltd, Nat Gas Res Inst, Xian 710075, Peoples R China
[5] PetroChina Tarim Oilfield Co, Korla 841000, Peoples R China
[6] Liaohe Oilfield, Dept Drilling & Prod Engn, Panjin 124010, Peoples R China
关键词
intelligent; well completion; Venturi; multi-parameter real-time monitoring; fluid flow simulation; flow monitoring chamber experiments; FLOW;
D O I
10.3390/pr12081597
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In this paper, based on electro-hydraulic composite intelligent well-completion technology, a new type of downhole multi-parameter real-time monitoring system design scheme is established. Firstly, a multi-parameter real-time monitoring system with a special structure is designed; secondly, its reliability is analysed by applying the method of numerical simulation; finally, in order to verify the reliability of the simulation results, a principle prototype is developed, and indoor experimental tests of fluid flow are carried out. The experimental results show that the flow rate is directly proportional to the differential pressure, and when the flow rate is certain, the higher the water content, the higher the differential pressure. The indoor experimental flow rate of 400 similar to 1000 m(3)/d is measured with high accuracy, and the error range is within 5%. Numerical simulation and experimental results with a high degree of fit, a flow rate of 400-1000 m(3)/d, the two error range within 10%, the integrated flow coefficient of the experimental value is stable between 0.75-0.815, the simulation value is stable between 0.80-0.86. The mutual verification of the two shows that the flow monitoring design meets the requirements and provides a reference basis for the structural design of the intelligent, well-completion multi-parameter real-time monitoring system.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Multi-parameter Sensitivity Analysis and Application Research in the Robust Optimization Design for Complex Nonlinear System
    Ma Tao
    Zhang Weigang
    Zhang Yang
    Tang Ting
    [J]. CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2015, 28 (01) : 55 - 62
  • [42] Multi-parameter Sensitivity Analysis and Application Research in the Robust Optimization Design for Complex Nonlinear System
    MA Tao
    ZHANG Weigang
    ZHANG Yang
    TANG Ting
    [J]. Chinese Journal of Mechanical Engineering, 2015, 28 (01) - 62
  • [43] Multi-parameter sensitivity analysis and application research in the robust optimization design for complex nonlinear system
    Tao Ma
    Weigang Zhang
    Yang Zhang
    Ting Tang
    [J]. Chinese Journal of Mechanical Engineering, 2015, 28 : 55 - 62
  • [44] Design of wearable and wireless multi-parameter monitoring system for evaluating cardiopulmonary function
    Li, Shih-Hong
    Lin, Bor-Shing
    Wang, Chen-An
    Yang, Cheng-Ta
    Lin, Bor-Shyh
    [J]. MEDICAL ENGINEERING & PHYSICS, 2017, 47 : 144 - 150
  • [45] Design of Multi-parameter Wireless Sensor Network Monitoring System in Precision Agriculture
    Wang Yitong
    Shi Yunbo
    Yu Xiaoyu
    [J]. 2014 FOURTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2014, : 721 - 725
  • [46] Design and Development of Multi-parameter Patient Monitoring System with Wireless Communication to PC
    Ekhare, Abhishek
    Chaskar, Uttam
    [J]. 2014 INTERNATIONAL CONFERENCE ON CONTROL, INSTRUMENTATION, COMMUNICATION AND COMPUTATIONAL TECHNOLOGIES (ICCICCT), 2014, : 21 - 25
  • [47] Design for Multi-Parameter Wireless Sensor Network Monitoring System Based on Zigbee
    Gui, Fen
    Liu, Xingqiao
    [J]. FUNCTIONAL MANUFACTURING TECHNOLOGIES AND CEEUSRO II, 2011, 464 : 90 - 94
  • [48] DESIGN OF MULTI-PARAMETER MONITORING SYSTEM FOR HYDRAULIC DEEP HOLE DRILLING RIG
    Zhang Meng
    Lei Weixin
    Yao Aiguo
    Zhang Junhua
    [J]. ICMET 09: PROCEEDINGS OF THE 2009 INTERNATIONAL CONFERENCE ON MECHANICAL AND ELECTRICAL TECHNOLOGY, 2009, : 81 - 86
  • [49] Design of wireless multi-parameter monitoring system for oral feeding of premature infants
    Wang, Yu-Lin
    Kuo, Hsing-Chien
    Wang, Lin-Yu
    Ko, Mei-Ju
    Lin, Bor-Shyh
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (07) : 1061 - 1069
  • [50] Design of wireless multi-parameter monitoring system for oral feeding of premature infants
    Yu-Lin Wang
    Hsing-Chien Kuo
    Lin-Yu Wang
    Mei-Ju Ko
    Bor-Shyh Lin
    [J]. Medical & Biological Engineering & Computing, 2016, 54 : 1061 - 1069