Evaluation of chronic perilunate dislocations: A comparative study of single-stage, two-stage ORIF, and salvage procedures

被引:0
|
作者
Dhal, Anil [1 ]
Prakash, Saket [2 ]
Khan, Yasim [3 ]
机构
[1] ESIC Med Coll, Dept Orthopaed, Faridabad, India
[2] All India Inst Med Sci AIIMS, Dept Trauma Emergency & Crit Care, Patna, Bihar, India
[3] Vardhman Mahavir Med Coll & Safdarjung Hosp, Sports Injury Ctr, New Delhi, India
关键词
Perilunate dislocations; Wrist injuries; Fracture dislocation; Lunate; Scaphoid; FRACTURE-DISLOCATIONS; OPEN REDUCTION; FIXATION;
D O I
10.1016/j.injury.2024.111466
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: This study aims to evaluate the outcomes of open reduction and internal fixation (ORIF) for chronic perilunate dislocations using single-stage, two-stage, and salvage procedures. The study also compares these approaches with each other and with results from existing literature. Methods: A total of 15 patients with chronic perilunate injuries from 2013 to 2019 were included in the study. Pre-operative and post-operative assessments were conducted using plain radiographs, with CT scans performed selectively for detailed morphology and fracture pattern analysis. Among the patients, 13 underwent ORIF, while 2 underwent salvage procedures. Among the ORIF cases, single-stage procedures were performed in 4 patients, and two-stage procedures in 9 patients. External fixators, including unilateral uniplanar external fixators (UUEF) and bilateral uniplanar external fixators (BUEF), were applied in 5 and 4 patients, respectively. Our methodology of treating chronic perilunate injuries has evolved over the years. We started with single stage ORIF then graduated to a two staged procedure initially using a external fixator as a carpal distractor applied only on the radial side and finally settling down with bilateral carpal distraction using external fixators both on the radial and ulnar sides. Results: Among the 15 patients, 3 were lost to follow-up. Of these, one underwent four-corner fusion, while the remaining two had UUEF. The mean time interval between injury and surgery was 3.60 months. The post-operative mean scapholunate angle measured 52.46 degrees, with a negative radio-lunate angle (indicating flexion) observed in two patients, while others showed a positive angle (indicating extension). Two cases exhibited nonunion and avascular necrosis (AVN) of the scaphoid, while one case presented with lunate AVN. Mid-carpal and radio-carpal arthritis was observed in 4 and 2 patients, respectively. Functional outcomes were evaluated using Mayo's wrist score categorized as good for two-stage BUEF cases and satisfactory for UUEF and single-stage procedures. Conclusion: Staged reduction utilizing the BUEF followed by open reduction has demonstrated superior outcomes when compared to UUEF, single-stage open reduction and salvage procedures.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Two-stage randomized response procedures as single stage procedures
    Zou, GH
    AUSTRALIAN JOURNAL OF STATISTICS, 1997, 39 (02): : 235 - 236
  • [2] Two-stage IMZ implants and ITI implants inserted in a single-stage procedure - A prospective comparative study
    Heydenrijk, K
    Raghoebar, GM
    Meijer, HJA
    van der Reijden, WA
    van Winkelhoff, AJ
    Stegenga, B
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (04) : 371 - 380
  • [3] Comparative assessment of single-stage and two-stage anaerobic digestion for the treatment of thin stillage
    Nasr, Noha
    Elbeshbishy, Elsayed
    Hafez, Hisham
    Nakhla, George
    El Naggar, M. Hesham
    BIORESOURCE TECHNOLOGY, 2012, 111 : 122 - 126
  • [4] Single-stage versus two-stage reconstruction in chronic multi ligament knee injury
    Khan, Mohammad Jesan
    Asif, Naiyer
    Sharma, Anubhav
    Siddiqui, Yasir Salam
    Khan, Abdul Qayyum
    INTERNATIONAL JOURNAL OF BURNS AND TRAUMA, 2022, 12 (02): : 35 - 44
  • [5] Reliability Assessment of Single-Stage/Two-Stage PFC converters
    Ranjbar, Amir Hossein
    Abdi, Babak
    Gharehpetian, Gevork B.
    Fahimi, Babak
    CPE: 2009 COMPATIBILITY AND POWER ELECTRONICS, 2009, : 253 - 257
  • [6] A unified design of single-stage and two-stage PFC converter
    Orabi, M
    Ninomiya, T
    PESC'03: 2003 IEEE 34TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1720 - 1725
  • [7] Comparisons of single-stage and two-stage approaches to genomic selection
    Torben Schulz-Streeck
    Joseph O. Ogutu
    Hans-Peter Piepho
    Theoretical and Applied Genetics, 2013, 126 : 69 - 82
  • [8] Comparisons of single-stage and two-stage approaches to genomic selection
    Schulz-Streeck, Torben
    Ogutu, Joseph O.
    Piepho, Hans-Peter
    THEORETICAL AND APPLIED GENETICS, 2013, 126 (01) : 69 - 82
  • [9] Comparative Analysis of Single-stage and Two-stage Fermentation Systems under Various Process Conditions
    Du, Jing
    Qian, Yuting
    Qu, Haoli
    Xi, Yonglan
    Huang, Hongying
    Jin, Hongmei
    Xu, Yueding
    Lu, Xiwu
    Chang, Zhizhou
    BIORESOURCES, 2017, 12 (01): : 326 - 343
  • [10] Bariatric Surgery In The Super-Super Obese - Single-Stage Versus Two-Stage Procedures.
    Mannur, Kesava Reddy
    Mukherjee, Samrat
    Thomas, Harun
    Devalia, Kalpana
    OBESITY SURGERY, 2010, 20 (08) : 991 - 991