Technical note: MR image-based synthesis CT for CyberKnife robotic stereotactic radiosurgery

被引:0
|
作者
Jiao, Shengxiu [1 ]
Zhao, Xiaoqian [1 ]
Zhou, Peng [2 ]
Geng, Mingying [2 ]
机构
[1] Shandong First Med Univ, Shandong Prov Hosp, Dept Nucl Med, Jinan, Shandong, Peoples R China
[2] Army Med Univ, Daping Hosp, Dept Canc Ctr, Chongqing, Peoples R China
来源
关键词
CyberKnife robotic stereotactic radiosurgery; synthesis CT; deep learning; MR-only radiation therapy; CONVOLUTIONAL NEURAL-NETWORK; BODY RADIATION-THERAPY; RADIOTHERAPY; GENERATION; SYSTEM;
D O I
10.1088/2057-1976/ad6a62
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study is to investigate whether deep learning-based sCT images enable accurate dose calculation in CK robotic stereotactic radiosurgery. A U-net convolutional neural network was trained using 2446 MR-CT pairs and used it to translate 551 MR images to sCT images for testing. The sCT of CK patient was encapsulated into a quality assurance (QA) validation phantom for dose verification. The CT value difference between CT and sCT was evaluated using mean absolute error (MAE) and the statistical significance of dose differences between CT and sCT was tested using the Wilcoxon signed rank test. For all CK patients, the MAE value of the whole brain region did not exceed 25 HU. The percentage dose difference between CT and sCT was less than +/- 0.4% on GTV (D-2(Gy), -0.29%, D95(Gy), -0.09%), PTV (D-2(Gy), -0.25%, D-95(Gy), -0.10%), and brainstem (max dose(Gy), 0.31%). The percentage dose difference between CT and sCT for most regions of interest (ROIs) was no more than +/- 0.04%. This study extended MR-based sCT prediction to CK robotic stereotactic radiosurgery, expanding the application scenarios of MR-only radiation therapy. The results demonstrated the remarkable accuracy of dose calculation on sCT for patients treated with CK robotic stereotactic radiosurgery.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Quality assurance of Cyberknife robotic stereotactic radiosurgery using an angularly independent silicon detector
    Alhujaili, Sultan Fahad
    Biasi, Giordano
    Alzorkany, Faisal
    Grogan, Garry
    Al Kafi, Muhammed A.
    Lane, Jonathan
    Hug, Benjamin
    Aldosari, Abdullah H.
    Alshaikh, Sami
    Farzad, Pejman Rowshan
    Ebert, Martin A.
    Moftah, Bela
    Rosenfeld, Anatoly B.
    Petasecca, Marco
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (01): : 76 - 88
  • [22] CT-Guided Fiducial Placement for CyberKnife Stereotactic Radiosurgery: An Initial Experience
    Evangelia Sotiropoulou
    Ιrene Stathochristopoulou
    Konstantinos Stathopoulos
    Kosmas Verigos
    Nikolaos Salvaras
    Loukas Thanos
    [J]. CardioVascular and Interventional Radiology, 2010, 33 : 586 - 589
  • [23] The Clinical Outcome of Hypofractionated Stereotactic Radiotherapy With CyberKnife Robotic Radiosurgery for Perioptic Pituitary Adenoma
    Puataweepong, Putipun
    Dhanachai, Mantana
    Hansasuta, Ake
    Dangprasert, Somjai
    Swangsilpa, Thiti
    Sitathanee, Chomporn
    Jiarpinitnun, Chuleeporn
    Vitoonpanich, Patamintita
    Yongvithisatid, Pornpan
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP10 - NP15
  • [24] A robotic 3-D motion simulator for enhanced accuracy in CyberKnife stereotactic radiosurgery
    Zhou, T
    Tang, J
    Dieterich, S
    Cleary, K
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 323 - 328
  • [25] CT-Guided Fiducial Placement for CyberKnife Stereotactic Radiosurgery: An Initial Experience
    Sotiropoulou, Evangelia
    Stathochristopoulou, Irene
    Stathopoulos, Konstantinos
    Verigos, Kosmas
    Salvaras, Nikolaos
    Thanos, Loukas
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2010, 33 (03) : 586 - 589
  • [26] Dosimetric comparison of Linac-based (BrainLAB®) and robotic radiosurgery (CyberKnife®) stereotactic system plans for acoustic schwannoma
    Dutta, Debnarayan
    Subramanian, S. Balaji
    Murli, V.
    Sudahar, H.
    Kurup, P. G. Gopalakrishna
    Potharaju, Mahadev
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2012, 106 (03) : 637 - 642
  • [27] CyberKnife image-guided stereotactic radiosurgery in the treatment of benign spinal tumors
    Dodd, RL
    Gibbs, I
    Adler, J
    Chang, SD
    [J]. JOURNAL OF NEUROSURGERY, 2004, 100 (04) : 787 - 788
  • [28] Dosimetric comparison of Linac-based (BrainLAB®) and robotic radiosurgery (CyberKnife®) stereotactic system plans for acoustic schwannoma
    Debnarayan Dutta
    S. Balaji Subramanian
    V. Murli
    H. Sudahar
    P. G. Gopalakrishna Kurup
    Mahadev Potharaju
    [J]. Journal of Neuro-Oncology, 2012, 106 : 637 - 642
  • [29] Implementation of MR-Based Synthetic CT for Stereotactic Radiosurgery Dose Calculation
    Li, F.
    Xu, Y.
    Lemus, O. M. D.
    Wang, T. J. C.
    Sisti, M. B.
    Wuu, C. S.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E547 - E547
  • [30] Treatment of stage I non-small cell lung cancer with CyberKnife, image-guided robotic stereotactic radiosurgery
    Ahn, Se Han
    Han, Min Sung
    Yoon, Jung Ho
    Jeon, Se Yong
    Kim, Cheol Hyeon
    Yoo, Hyung Jun
    Lee, Jae Cheol