ObjectivesEarly defibrillation with an automated external defibrillator (AED) can effectively improve the survival rate of patients with out-of-hospital cardiac arrest (OHCA). Placing AEDs in public locations can reduce the defibrillation response interval from collapse to defibrillation. Most public AEDs are currently placed in a stationary way (S-AED) with limited coverage area. Bus mounted AED (B-AED) can be delivered directly to the demand point. Although B-AEDs are only available during bus operating hours, they provide greater coverage area. When the number of available AEDs is insufficient, better coverage may be achieved by placing a portion of AEDs as B-AEDs. Our purpose is developing a model to determine the optimal locations of B-AEDs and S-AEDs with a predetermined number of available AEDs. The goal is to maximize the total coverage level of all demand points.MethodsWe proposed a joint location model to place B-AEDs and S-AEDs based on the p-median problem (JPMP). Using data from Chang'an District, Xi'an City, China, we determined the optimal AED deployment. The performance of JPMP was compared with several other models. The coverage results of JPMP are analyzed in details, including the quantity assignment, coverage level, and geographical location of B-AEDs and S-AEDs. The impact of the bus departure intervals on coverage was also discussed.ResultsThe use of B-AEDs results in an average 98.43% increase in the number of covered demand points, and an average 74.05% increase in total coverage level. In optimal AED deployment, B-AEDs coverage follows an inverted U-shaped curve with increasing number of available AEDs. It begins to decrease when all demand points during the operating hours are covered. With a constant number of available AEDs, the total coverage level increases and then decreases as the bus departure interval increases. The larger the number of available AEDs, the smaller the optimal departure interval.ConclusionsWith a given number of available AEDs, combinational deployment of B-AEDs and S-AEDs significantly improves the coverage level. B-AEDs are recommended when AEDs are insufficient. If more AEDs are available, better coverage can be obtained with reasonable location of S-AEDs and B-AEDs.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Energy attenuator for pediatric application of an automated external defibrillator
    Jorgenson, D
    Morgan, C
    Snyder, D
    Griesser, H
    Solosko, T
    Chan, K
    Skarr, T
    CRITICAL CARE MEDICINE, 2002, 30 (04) : S145 - S147
  • [32] A reference automated external defibrillator provider course for Europe
    Hoke, RS
    Chamberlain, DA
    Handley, AJ
    RESUSCITATION, 2006, 69 (03) : 421 - 433
  • [33] The use of an automated external defibrillator in a victim of car accident
    Puchalski, Bartosz
    Kwasizur, Marek
    Platek, Anna E.
    Szymanski, Filip M.
    KARDIOLOGIA POLSKA, 2014, 72 (12) : 1400 - 1400
  • [34] The automated external defibrillator: Critical link in the chain of survival
    Ramaswamy, K
    Page, RL
    ANNUAL REVIEW OF MEDICINE-SELECTED TOPICS IN THE CLINICAL SCIENCES, 2003, 54 : 235 - 243
  • [35] Automated external defibrillator in sport: absolutely always available
    Kramer, Efraim B.
    BRITISH JOURNAL OF SPORTS MEDICINE, 2013, 47 (18) : 1138 - 1138
  • [36] Performance of automated external defibrillator in moving ambulance vehicles
    Kyung Woon Jeung
    Jong Geun Yun
    Yong Il Min
    Tag Heo
    Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, 17 (Suppl 3)
  • [37] Does your facility need an Automated External Defibrillator?
    Binkley, H
    Hollandsworth, K
    STRENGTH AND CONDITIONING JOURNAL, 2005, 27 (03) : 16 - 24
  • [38] Automated External Defibrillator Awareness in the US Latino Population
    McGovern, Shaun K.
    Owen, D. Daphne
    Murray, Andrew
    Leary, Marion
    Del Rios, Marina
    Abella, Benjamin S.
    Blewer, Audrey L.
    CIRCULATION, 2017, 136
  • [39] Benefits vs the harms of automated external defibrillator use
    Landau, WM
    Jaffe, AS
    Wetzel, RD
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (24): : 2849 - 2850
  • [40] AEDNav: indoor navigation for locating automated external defibrillator
    Rao, Gaurav
    Mago, Vijay
    Lingras, Pawan
    Savage, David W.
    BMC MEDICAL INFORMATICS AND DECISION MAKING, 2022, 22 (SUPPL 2)