A comparative analysis of preclinical computed tomography radiomics using cone-beam and micro-computed tomography scanners

被引:0
|
作者
Brown, Kathryn H. [1 ]
Kerr, Brianna N. [1 ]
Pettigrew, Mihaela [1 ]
Connor, Kate [2 ,3 ]
Miller, Ian S. [2 ,3 ,4 ]
Shiels, Liam [2 ,3 ]
Connolly, Colum [2 ,3 ]
Mcgarry, Conor K. [1 ,5 ]
Byrne, Annette T. [2 ,3 ,4 ]
Butterworth, Karl T. [1 ]
机构
[1] Queens Univ Belfast, Patrick G Johnston Ctr Canc Res, Belfast, North Ireland
[2] Royal Coll Surgeons Ireland, Dept Physiol & Med Phys, Dublin, Ireland
[3] Royal Coll Surgeons Ireland, Ctr Syst Med, Dublin, Ireland
[4] Royal Coll Surgeons Ireland, Natl Preclin Imaging Ctr, Dublin, Ireland
[5] Belfast Hlth & Social Care Trust, Northern Ireland Canc Ctr, Belfast, North Ireland
基金
英国国家替代、减少和改良动物研究中心; 爱尔兰科学基金会;
关键词
Radiomics; Preclinical; Computed tomography; Cone-beam; Micro; Phantom; Tissue density; Reliability; FEATURE STABILITY; CT; FEATURES; IMAGES; IMPACT; HEAD;
D O I
10.1016/j.phro.2024.100615
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Radiomics analysis extracts quantitative data (features) from medical images. These features could potentially reflect biological characteristics and act as imaging biomarkers within precision medicine. However, there is a lack of cross-comparison and validation of radiomics outputs which is paramount for clinical implementation. In this study, we compared radiomics outputs across two computed tomography (CT)-based preclinical scanners. Materials and methods: Cone beam CT (CBCT) and mu CT scans were acquired using different preclinical CT imaging platforms. The reproducibility of radiomics features on each scanner was assessed using a phantom across imaging energies (40 & 60 kVp) and segmentation volumes (44-238 mm(3)). Retrospective mouse scans were used to compare feature reliability across varying tissue densities (lung, heart, bone), scanners and after voxel size harmonisation. Reliable features had an intraclass correlation coefficient (ICC) > 0.8. Results: First order and GLCM features were the most reliable on both scanners across different volumes. There was an inverse relationship between tissue density and feature reliability, with the highest number of features in lung (CBCT=580, =580, mu CT=734) =734) and lowest in bone (CBCT=110, =110, mu CT=560). =560). Comparable features for lung and heart tissues increased when voxel sizes were harmonised. We have identified tissue-specific preclinical radiomics signatures in mice for the lung (133), heart (35), and bone (15). Conclusions: Preclinical CBCT and mu CT scans can be used for radiomics analysis to support the development of meaningful radiomics signatures. This study demonstrates the importance of standardisation and emphasises the need for multi-centre studies.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Cone-Beam Computed Tomography: Beyond Diagnostics
    Perel, Morton L.
    IMPLANT DENTISTRY, 2015, 24 (04) : 367 - 367
  • [32] Comparative analysis of bone density measurements by using multislice spiral and cone-beam computed tomography
    Bal, Cenkhan
    Unsal, Gokce Soganci
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (03) : 388 - 389
  • [33] Evaluation of Anatomoradiological Findings on Trigeminal Neuralgia Patients Using Computed Tomography and Cone-Beam Computed Tomography
    Aksoy, Secil
    Sayin Sakul, Arzu
    Gorur, Durmus Ilker
    Sakul, Bayram Ufuk
    Orhan, Kaan
    DIAGNOSTICS, 2022, 12 (01)
  • [34] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] Evaluation of maxillary trabecular microstructure as an indicator of implant stability by using 2 cone beam computed tomography systems and micro-computed tomography
    Kulah, Kivanc
    Gulsahi, Ayse
    Kamburoglu, Kivanc
    Geneci, Ferhat
    Ocak, Mert
    Celik, H. Hamdi
    Ozen, Tuncer
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2019, 127 (03): : 247 - 256
  • [36] Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography
    Hirschinger, Veronika
    Hanke, Sebastian
    Hirschfelder, Ursula
    Hofmann, Elisabeth
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (02): : 152 - 163
  • [37] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378
  • [38] Cone-beam Computed Tomography of the Paranasal Sinuses: Comparison Study with Multidetector Computed Tomography
    Kei, P. L.
    Tan, J. S. P.
    Leong, J. L.
    Kwok, Y. M.
    Lim, W. E. H.
    Chan, L. L.
    HONG KONG JOURNAL OF RADIOLOGY, 2013, 16 (02): : 110 - 116
  • [39] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [40] Unsupervised computed tomography and cone-beam computed tomography image registration using a dual attention network
    Hu, Rui
    Yan, Hui
    Nian, Fudong
    Mao, Ronghu
    Li, Teng
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (07) : 3705 - 3716