Flow Cytometry Method Validation Protocols

被引:8
|
作者
Selliah, Nithianandan [1 ]
Nash, Veronica [1 ]
Eck, Steven [2 ]
Green, Cherie [3 ]
Oldaker, Teri
Stewart, Jennifer [4 ]
Vitaliti, Alessandra [5 ]
Litwin, Virginia [6 ]
机构
[1] Cerba Res, Lake Success, NY USA
[2] AstraZeneca, Gaithersburg, MD USA
[3] Ozette Technol, Seattle, WA USA
[4] Flow Contract Site Lab LLC, Bothell, WA USA
[5] Novartis Pharm AG, Novartis Inst Biomed Res, Basel, Switzerland
[6] Eurofins Biopharm Serv, Montreal, PQ, Canada
来源
CURRENT PROTOCOLS | 2023年 / 3卷 / 08期
关键词
biomarker; fit-for-purpose validation; flow cytometry; precision; sensitivity; RECOMMENDATIONS; GUIDELINES;
D O I
10.1002/cpz1.868
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analytical method validation provides a means to ensure that data are credible and reproducible. This article will provide a brief introduction to analytical method validation as applied to cellular analysis by flow cytometry, along with practical procedures for four different types of validation. The first, Basic Protocol 1 (the limited validation protocol), is recommended for research and non-regulated laboratories. Next, Basic Protocol 2) presents a reasonable, fit-for-purpose validation approach appropriate for biopharma and research settings. Basic Protocol 3 addresses the type of validation performed in clinical laboratories for moderate-risk tests developed in house. Finally, Basic Protocol 4 describes the process that should be applied whenever a method is being transferred from one facility to another. All four validation plans follow the fit-for-purpose validation approach, in which the validation parameters are selected based on the intended use of the assay. These validation protocols represent the minimal requirement and may not be applicable for every intended use such as high-risk clinical assays or data to be used as a primary endpoint in a clinical trial. The recommendations presented here are consistent with the white papers published by the American Association of Pharmaceutical Scientists and the International Clinical Cytometry Society, as well as with Clinical Laboratory Standards Institute Guideline H62: Validation of Assays Performed by Flow Cytometry (CLSI, 2021). (c) 2023 Wiley Periodicals LLC.Basic Protocol 1: Limited validationBasic Protocol 2: Fit-for-purpose validation for biopharma and research settingsBasic Protocol 3: Validation for moderate clinical risk laboratory developed testsBasic Protocol 4: Transfer validation
引用
收藏
页数:34
相关论文
共 50 条
  • [41] CONJUGATED ANTIBODIES FOR FLOW CYTOMETRY IS AN ESSENTIAL TOOL THAT REQUIRES VALIDATION
    Tay, Andy
    Lab Manager, 2021, 16 (01): : 43 - 45
  • [42] Validation of the Flow Cytometry-Based In Vitro Micronucleus Assay
    Zhou, C.
    Ou, H.
    Tu, H.
    Xu, L.
    Chang, Y.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2015, 56 : S73 - S73
  • [43] Comparison of two peripheral mononuclear cell isolation protocols for flow cytometry crossmatching
    Apithy, M. -J.
    Desoutter, J.
    Guillaume, N.
    HLA, 2018, 91 (02) : 124 - 126
  • [44] Validation of a Spectral Flow Cytometry Platform for Use in a GxP Environment
    Colvin, Christopher
    Kraus, Emma
    Lawrence, Austin
    Best, Victoria
    Varia, Sapna
    MOLECULAR THERAPY, 2024, 32 (04) : 866 - 867
  • [45] A method to study apoptosis in eosinophils by flow cytometry
    Sandström, K
    Häkansson, L
    Lukinius, A
    Venge, P
    JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 240 (1-2) : 55 - 68
  • [46] A MULTIPARAMETER FLOW CYTOMETRY METHOD FOR PNH DIAGNOSIS
    Li, Susann
    Jacobsson, Stefan
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2009, 76B (06) : 426 - 427
  • [47] A FLOW CYTOMETRY METHOD FOR CHARACTERIZING PLATELET ACTIVATION
    Alzua, Brian
    Smith, Mark
    Chen, Yan
    PROCEEDINGS OF THE 2020 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2020), 2020,
  • [48] A microencapsulation method based on flow cytometry technology
    Paul, C
    Gregori, GJ
    Park, K
    Robinson, JP
    CYTOMETRY PART A, 2004, 59A (01): : 156 - 156
  • [49] The curvHDR method for gating flow cytometry samples
    Ulrike Naumann
    George Luta
    Matthew P Wand
    BMC Bioinformatics, 11
  • [50] Validation and quality control of hematolymphoid neoplasm immunophenotyping by flow cytometry
    Wu Lijuan1
    2.Department of Hematopathology
    国际检验医学杂志, 2012, 33 (23) : 2852 - 2858