Characterization of a 3D prototyping semi-automated filter holder system for RQR radiation qualities

被引:0
|
作者
de Almeida Junior, Jose Neres [1 ]
Potiens, Maria da Penha Albuquerque [1 ]
Rodrigues Junior, Orlando [1 ]
机构
[1] Inst Pesquisas Energet & Nucl IPEN CNEN SP, Ctr Metrol Radiacoes Ionizantes CEMRI, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Kerma-area product; Dosimetry; Calibration method; Spectroscopy;
D O I
10.1016/j.radphyschem.2024.111897
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Characterizing radiation measurement systems, such as diagnostic radiology systems for RQR and RQA, is essential for ensuring reliable results in standardized instrument calibration laboratories. Quality control of dosimetry devices, such as patient dose calibrators (PDCs), a reference meter, is crucial for ensuring accurate measurements. This study demonstrates the use of spectrometry and ionization chambers to characterize a set of semi-automated 3D prototyping filter holder systems, developed in a previously project, designed for applications such as Kerma-Area Product (KAP) meter calibration. The set of 3D prototypes were adjusted to a filter wheel and characterized using an X-ray spectrometer, followed by an ionization chamber, according to international standards. The characterization of radiation qualities from 50 to 150 kV in diagnostic radiology was performed using the substitution method: first with an ionization chamber, then with a PDC. The PDC was calibrated for KAP and Air Kerma quantities, considering the conditions of the X-ray system and factors such as temperature, humidity, and pressure. Spectrometric analysis and the use of an ionization chamber were effective in determining these parameters. Spectral characterization allowed for accurate measurements to establish proper quality control, then it is possible to use the PDC calibrated for calibration procedures for KAP meters. Future studies intend to compare these results with computational simulations using the TOPAS Monte Carlo code to validate the calibration method.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software
    Ebersberger, Ullrich
    Marcus, Roy P.
    Schoepf, U. Joseph
    Lo, Gladys G.
    Wang, Yining
    Blanke, Philipp
    Geyer, Lucas L.
    Gray, J. Cranston, III
    McQuiston, Andrew D.
    Cho, Young Jun
    Scheuering, Michael
    Canstein, Christian
    Nikolaou, Konstantin
    Hoffmann, Ellen
    Bamberg, Fabian
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 191 - 199
  • [22] Semi-Automated 3D Registration for Heterogeneous Unmanned Robots Based on Scale Invariant Method
    Balta, Haris
    Velagic, Jasmin
    De Cubber, Geert
    Siciliano, Bruno
    2019 IEEE INTERNATIONAL SYMPOSIUM ON SAFETY, SECURITY, AND RESCUE ROBOTICS (SSRR), 2019, : 263 - 269
  • [23] Semi-automated DIRSIG scene modeling from 3D LIDAR and passive imaging sources
    Lach, S. R.
    Brown, S. D.
    Kerekes, J. P.
    LASER RADAR TECHNOLOGY AND APPLICATIONS XI, 2006, 6214
  • [24] Semi-automated mitral valve morphometry and computational stress analysis using 3D ultrasound
    Pouch, Alison M.
    Xu, Chun
    Yushkevich, Paul A.
    Jassar, Arminder S.
    Vergnat, Mathieu
    Gorman, Joseph H., III
    Gorman, Robert C.
    Sehgal, Chandra M.
    Jackson, Benjamin M.
    JOURNAL OF BIOMECHANICS, 2012, 45 (05) : 903 - 907
  • [25] Semi-automated approach to indoor mapping for 3D as-built building information modeling
    Hong, Sungchul
    Jung, Jaehoon
    Kim, Sangmin
    Cho, Hyoungsig
    Lee, Jeongho
    Heo, Joon
    COMPUTERS ENVIRONMENT AND URBAN SYSTEMS, 2015, 51 : 34 - 46
  • [26] Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software
    Ullrich Ebersberger
    Roy P. Marcus
    U. Joseph Schoepf
    Gladys G. Lo
    Yining Wang
    Philipp Blanke
    Lucas L. Geyer
    J. Cranston Gray
    Andrew D. McQuiston
    Young Jun Cho
    Michael Scheuering
    Christian Canstein
    Konstantin Nikolaou
    Ellen Hoffmann
    Fabian Bamberg
    European Radiology, 2014, 24 : 191 - 199
  • [27] Visually interactive semi-automated 3D segmentation of cine cardiac magnetic resonance images
    Papademetris, X
    Rambo, J
    Dione, DP
    Sinusas, AJ
    Duncan, JS
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (02) : 7A - 7A
  • [28] Semi-Automated Segmentation Method to Quantify Carotid Atherosclerosis from 3D Ultrasound Images
    Ukwatta, E.
    Awad, J.
    Ward, A.
    Buchanan, D.
    Samarabandu, J.
    Parraga, G.
    Fenster, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Semi-automated 3D fluorescence speckle analyzer (3D-Speckler) for microscope calibration and nanoscale measurement
    Loi, Jonathan
    Qu, Xiaofei
    Suzuki, Aussie
    JOURNAL OF CELL BIOLOGY, 2023, 222 (04):
  • [30] Semi-automated measurement of the Cobb angle from 3D mesh models of the scoliotic spine
    Petkovic, Uros
    Korez, Robert
    Vrtovec, Tomaz
    PROCEEDINGS OF THE 10TH INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, 2017, : 137 - 140