Evaluation of an Enzymatic Hemoglobin A1C Assay

被引:0
|
作者
Majeed, Numan [1 ]
Kanani, Fatima [1 ]
Zubairi, Adnan Mustafa [1 ]
机构
[1] Indus Hosp & Hlth Network, Karachi, Pakistan
关键词
Glycatedhemoglobin; Alinity C; HPLC; method validation; A(1C);
D O I
10.21649/akemu.v30i2.5567
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Different modalities have been designed for estimation of HbA1c, that include ion-exchange High Performance Liquid Chromatography (HPLC), immunoassay, enzymatic assays and capillary electrophoresis. Although based on different principles, these analytical processes have to exhibit robust performance so that an overall comparability of assay values can be ensured which are traceable to the available reference method. Objectives: Objective of the study was to evaluate HbA1c measurement on Abbott Alinity C system against ion exchange high performance liquid chromatography. Methods: We performed different experiments to evaluate measurement of HbA1c on Alinity C system by Abbott. These studies included accuracy, precision, linearity, carry over and method comparison in patients without any hemoglobin variants. Evaluation Protocol (EP) evaluator was used for data analysis. Results: All the experiments passed the minimum passing criteria. All the claims by the vendor were successfully verified with and addition that vendor claims 12-hour stability while our study showed a stability of 18 hours. In precision the coefficient of variance in our experiment showed better results. Conclusion: Alinity C system can be used reliably and efficiently for the assessment of HbA1c in patients without haemoglobin variants as our study did not include samples with variant hemoglobin.
引用
收藏
页码:184 / 190
页数:7
相关论文
共 50 条
  • [41] The Highs and Lows of Hemoglobin A1c
    Lavis, Victor R.
    CARDIOLOGY, 2016, 134 (03) : 325 - 326
  • [42] Problems with measurements of hemoglobin A1c
    Smith, Steven A.
    Montori, Victor M.
    Isley, William L.
    Burritt, Mary F.
    MAYO CLINIC PROCEEDINGS, 2006, 81 (08) : 1130 - 1130
  • [43] Interpretation of Hemoglobin A1c Values
    Sacks, David B.
    John, W. Garry
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (22): : 2271 - 2272
  • [44] Translating the A1C assay
    Kahn, Richard
    Fonseca, Vivian
    DIABETES CARE, 2008, 31 (08) : 1704 - 1707
  • [45] Should hemoglobin A1c be renamed?
    Levetan, CS
    Dawn, KR
    Christian, CA
    Odel, JA
    DIABETES, 1999, 48 : A415 - A415
  • [46] Streptococcus;: Radioisotopes;: Hemoglobin A1c
    不详
    LABORATORY MEDICINE, 1998, 29 (12) : 737 - 739
  • [47] Unexpected Hemoglobin A1c Results
    Sofronescu, Alina-Gabriela
    Williams, Laurie M.
    Andrews, Dorinda M.
    Zhu, Yusheng
    CLINICAL CHEMISTRY, 2011, 57 (02) : 153 - 156
  • [48] Measuring and reporting hemoglobin A1c
    Sacks, David B.
    CLINICAL BIOCHEMISTRY, 2012, 45 (13-14) : 1046 - 1047
  • [49] Standardization of hemoglobin A1c values
    Jain, M
    McCall, A
    Riddle, M
    ANNALS OF INTERNAL MEDICINE, 2000, 132 (08) : 676 - 676
  • [50] DOSAGE OF HEMOGLOBIN A1C BY ISOELECTROFOCUSING
    SCHOOS, R
    SCHOOSBARBETTE, S
    LAMBOTTE, C
    CLINICA CHIMICA ACTA, 1978, 86 (01) : 61 - 65