Investigation on contact surfaces damage of copper contacts by an electric arc

被引:0
|
作者
Hadda, Kada [1 ,2 ]
Beloufa, Amine [1 ]
Amirat, Mohamed [1 ]
Boutte, Aissa [2 ]
机构
[1] Univ Ain Temouchent, Smart Struct Lab, Ain Temouchent, Algeria
[2] Algerian Space Agcy, Satell Dev Ctr Bir El Djir, Oran, Algeria
关键词
automotive electrical connector; pure copper; electric arc; connector damage; experimental tests; contact surfaces analysis by SEM and EDX; SILVER; CONNECTOR; EROSION; AIR;
D O I
10.24425/ame.2024.149638
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Electrical contacts are used in general electrical applications such as circuit breakers, switches, relays, connectors, etc. Repeated separations of the parts (anode and cathode) of these contacts under input power can damage their contact materials. The objective of this work is to study the influence of the input electric power (100 W and 256 W) and the contact sizes (hemispherical contacts with diameters D = 5 mm and D = 8 mm) on the variation of the arc energy and the damage of the contact surfaces by oxidization or by erosion. These parameters are decisive for selecting the best arc-resistant contact sample. Experimental results, SEM, and EDX analysis show that high input power leads to more degradation of contact surfaces. Also, the smaller and the larger contact diameters generate similar arcing energies with similar erosion sizes and oxidation rates, but the contact with a small diameter has a higher lifetime (1215 operations) and oxidizes less quickly than the one with a large diameter that has a lower lifetime (374 operations). Experimental and numerical analyses demonstrate that arc mobility is one of several factors influencing the change in contact lifetime.
引用
收藏
页码:251 / 271
页数:21
相关论文
共 50 条
  • [21] Temperature measurement of copper contact surfaces
    Landfried, R.
    Leblanc, T.
    Andlauer, R.
    Klonowski, T.
    Teste, Ph
    PROCEEDINGS OF THE FIFTY-SIXTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2010, : 148 - 152
  • [22] Electric properties of nanoscale contacts on Si(111) surfaces
    Hasunuma, R
    Komeda, T
    Tokumoto, H
    APPLIED SURFACE SCIENCE, 1998, 130 : 84 - 89
  • [23] The contact resistance of rolling silver coated copper contacts
    Rudolphi, AK
    Jacobson, S
    ELECTRICAL CONTACTS - 1997: PROCEEDINGS OF THE FORTY-THIRD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 1997, : 33 - 40
  • [24] Contact Resistance and Arc-free Commutation Current of Tungsten-clad Copper Contacts for a Hybrid DC Switch
    Yasuoka, Koichi
    Yamada, Yuta
    Chen, Mo
    PROCEEDINGS OF THE 2019 65TH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS (ELECTRICAL CONTACTS-2019), 2019, : 359 - 362
  • [25] Experimental Investigation of Electric Arc Characteristics
    Kireev, Pavel
    Nagay, Ivan
    Nagay, Vladimir
    PROCEEDINGS OF THE 9TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2017), 2017, : 414 - 417
  • [26] Molecular dynamics investigation of the effect of copper nanoparticle on the solid contact between friction surfaces
    Hu, Chengzhi
    Bai, Minli
    Lv, Jizu
    Liu, Hao
    Li, Xiaojie
    APPLIED SURFACE SCIENCE, 2014, 321 : 302 - 309
  • [27] A theoretic and experimental investigation in stationary electric contacts
    Karagiannopoulos, CG
    Psomopoulos, CS
    Bourkas, PD
    MODELLING AND SIMULATION IN MATERIALS SCIENCE AND ENGINEERING, 2001, 9 (03) : 181 - 192
  • [28] Potential measurements on electric contacts - An experimental investigation
    Karagiannopoulos, CG
    Agoris, DP
    Psomopoulos, CS
    Bourkas, PD
    MEASUREMENT, 2000, 27 (01) : 61 - 69
  • [29] COMPOSITION OF ELECTRIC ARC PLASMA WITH COPPER VAPOURS
    Coufal, O.
    Bartlova, M.
    Babich, I
    Boretskij, V
    Veklich, A.
    XVIIITH SYMPOSIUM ON PHYSICS OF SWITCHING ARC, 2009, : 142 - 145
  • [30] Copper cooling plates for electric arc furnaces
    Wobker, WG
    Böert, F
    Dratner, C
    STAHL UND EISEN, 2003, 123 (09): : 29 - 32