Assessment of alternative metrics in the application of infrared thermography to detect muscle damage in sports

被引:0
|
作者
Verderber, Lukas [1 ]
da Silva, Willian [2 ]
Aparicio-Aparicio, Inmaculada [3 ]
Germano, Andresa M. C. [1 ]
Carpes, Felipe P. [4 ]
Priego-Quesada, Jose Ignacio [3 ,5 ]
机构
[1] Tech Univ Chemnitz, Inst Human Movement Sci & Hlth, Motor Control Cognit & Neurophysiol, Chemnitz, Germany
[2] Pontificia Univ Catolica Valparaiso, Escuela Kinesiol, Fac Ciencias, Valparaiso, Chile
[3] Univ Valencia, Dept Phys Educ & Sports, Res Grp Sports Biomech GIBD, Valencia, Spain
[4] Fed Univ Pampa, Appl Neuromech Res Grp, Uruguaiana, Brazil
[5] Univ Valencia, Dept Physiol, Res Grp Med Phys GIFIME, Valencia, Spain
关键词
delayed muscle onset soreness; pain; skin temperature; thermal image; SKIN; EXERCISE;
D O I
10.1088/1361-6579/ad7ad3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective. The association between muscle damage and skin temperature is controversial. We hypothesize that including metrics that are more sensitive to individual responses by considering variability and regions representative of higher temperature could influence skin temperature outcomes. Here, the objective of the study was to determine whether using alternative metrics (TMAX, entropy, and pixelgraphy) leads to different results than mean, maximum, minimum, and standard deviation (SD) skin temperature when addressing muscle damage using infrared thermography. Approach. Thermal images from four previous investigations measuring skin temperature before and after muscle damage in the anterior thigh and the posterior lower leg were used. The TMAX, entropy, and pixelgraphy (percentage of pixels above 33 degrees C) metrics were applied. Main results. On 48 h after running a marathon or half-marathon, no differences were found in skin temperature when applying any metric. Mean, minimum, maximum, TMAX, and pixelgraphy were lower 48 h after than at basal condition following quadriceps muscle damage (p < 0.05). Maximum skin temperature and pixelgraphy were lower 48 h after than the basal condition following muscle damage to the triceps sural (p < 0.05). Overall, TMAX strongly correlated with mean (r = 0.85) and maximum temperatures (r = 0.99) and moderately with minimum (r = 0.66) and pixelgraphy parameter (r = 0.64). Entropy strongly correlates with SD (r = 0.94) and inversely moderately with minimum temperature (r = -0.53). The pixelgraphy moderately correlated with mean (r = 0.68), maximum (r = 0.62), minimum (r = 0.58), and TMAX (r = 0.64). Significance. Using alternative metrics does not change skin temperature outcomes following muscle damage of lower extremity muscle groups.
引用
收藏
页数:9
相关论文
共 38 条
  • [31] The Application of Infrared Thermography in the Assessment of BEMER Physical Vascular Therapy on Body Surface Temperature in Racing Thoroughbreds: A Preliminary Study
    Nawrot, Karolina
    Soroko-Dubrovina, Maria
    Zielinska, Paulina
    Dudek, Krzysztof
    Howell, Kevin
    ANIMALS, 2024, 14 (11):
  • [32] Lightning damage assessment on solar panels using in-house portable infrared thermography camera with Convolutional Neural Network (CNN) algorithm
    Chandrasegaran, Ormiila
    Mustapha, Faizal
    Abdullah, Mohd Na'im
    Anwar, Murniwati
    Mustapha, Mazli
    Adzis, Zuraimy
    NONDESTRUCTIVE TESTING AND EVALUATION, 2024,
  • [33] Thermal condition of muscle area around the temporomandibular joint in patient with systemic lupus erythematosus using infrared thermography application: A case report
    Rahmayani, Liana
    Yahya, Mustanir
    Soraya, Cut
    Syahreza, Saumi
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (05): : 674 - 679
  • [34] Exploring alternative measurement methods and greenness metrics for nitrate levels in coconut water: android application and mid-infrared spectroscopy approaches
    Arunachalam, V.
    Toraskar, Ashwini D.
    Mardolkar, Krutika R.
    Das, Bappa
    CHEMICAL PAPERS, 2024, 78 (14) : 8031 - 8044
  • [35] In situ Passive Infrared Thermography Application for the Assessment of Localized Mechanical Properties of Tungsten Inert Gas-Welded Inconel 625 Alloys
    Nathir A. Rawashdeh
    Anas M. Atieh
    Diala Bani Mostafa
    Journal of Materials Engineering and Performance, 2022, 31 : 3953 - 3961
  • [36] In situ Passive Infrared Thermography Application for the Assessment of Localized Mechanical Properties of Tungsten Inert Gas-Welded Inconel 625 Alloys
    Rawashdeh, Nathir A.
    Atieh, Anas M.
    Bani Mostafa, Diala
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2022, 31 (05) : 3953 - 3961
  • [37] APPLICATION OF NEAR-INFRARED SPECTROSCOPY FOR THE ASSESSMENT OF THE OXYGENATION LEVEL OF MYOGLOBIN AND HEMOGLOBIN IN CARDIAC-MUSCLE INVIVO
    THORNILEY, MS
    HOUSTON, R
    WICKRAMASINGHE, YABD
    ROLFE, P
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1990, 18 (06) : 1195 - 1196
  • [38] A short review of application of near-infrared spectroscopy (NIRS) for the assessment of microvascular post-occlusive reactive hyperaemia (PORH) in skeletal muscle
    Hendrick, Elizabeth
    Jamieson, Alexandra
    Chiesa, Scott T.
    Hughes, Alun D.
    Jones, Siana
    FRONTIERS IN PHYSIOLOGY, 2024, 15