Performance of channel shear connectors in steel frame with reinforced concrete infill walls

被引:0
|
作者
Yu, Jiali [1 ]
Sun, Guohua [1 ]
Liu, Wenyuan [1 ]
Li, Ming [1 ]
Yang, Wenxia [2 ]
机构
[1] Suzhou Univ Sci & Technol, Sch Civil Engn, Suzhou 215011, Peoples R China
[2] Jiangsu Huning Steel Mech Co Ltd, Yixing 214231, Peoples R China
关键词
Steel frame; Infill wall; Channel shear connector; Push-out test; Finite element analysis; COMPOSITE STEEL; BEHAVIOR; STUDS;
D O I
10.1016/j.istruc.2024.107303
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To examine the mechanical properties of channel shear connectors employed in steel frame with reinforced concrete infill wall (SRCW) structures, the improved push-out tests were performed on three specimens of channel shear connectors subjected to the monotonic and cyclic loading. This study investigated the influences of loading protocol and concrete strength on the mechanical behavior of channel shear connectors. After the refined finite element (EF) models of channel shear connectors were validated based on the push-out tests, a systematical parametric analysis was conducted to evaluate the effects of RC infill wall thickness, concrete strength, and channel dimensions on its shear strength of the channel shear connectors. In addition, this study also compared the accuracy of the CSA S16, AISC 360 and GB50017 design code in predicting the shear capacity of channel shear connectors in SRCW structures. The experimental results and parametric studies indicated that the current design equations inaccurately evaluate the shear capacity of channel shear connectors used in SRCW structures. Consequently, an alternative equation was developed to estimate the shear-resistant capacity of channel shear connectors in SRCW structures, which provided the desirable calculation precision for engineering design.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Performance-based plastic design of composite partially-restrained steel frame-reinforced concrete infill walls with concealed vertical slits
    Sun, Guohua
    Wei, Xin
    Gu, Qiang
    Wang, Yue
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (04) : 1445 - 1474
  • [42] Seismic performance evaluation of steel and GFRP reinforced concrete shear walls at high temperature
    Belay A.
    Wondimu T.
    [J]. Journal of Engineering and Applied Science, 2023, 70 (01):
  • [43] Performance level thresholds and damage evaluation for composite partially-restrained steel frame-reinforced concrete infill walls with concealed vertical slits
    Sun, Guohua
    Li, Qicai
    Gu, Qiang
    Yang, Wenxia
    [J]. BULLETIN OF EARTHQUAKE ENGINEERING, 2017, 15 (09) : 3639 - 3672
  • [44] Study on seismic performance of shear walls with steel fiber reinforced concrete in boundary elements
    [J]. Zhao, Jun (zhaoj@zzu.edu.cn), 1600, Editorial Board of Journal of Basic Science and (24):
  • [45] Seismic performance of reinforced concrete frame strengthened with an imperfect steel plate shear wall
    Batikha, Mustafa
    Mouna, Yara
    [J]. INTERNATIONAL JOURNAL OF STRUCTURAL ENGINEERING, 2020, 10 (04) : 380 - 404
  • [46] Performance of bamboo reinforced concrete masonry shear walls
    Moroz, J. G.
    Lissel, S. L.
    Hagel, M. D.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2014, 61 : 125 - 137
  • [47] Hysteretic performance of reinforced concrete cavity shear walls
    Xu, Gang
    Li, Aiqun
    [J]. STRUCTURAL CONCRETE, 2020, 21 (02) : 610 - 624
  • [48] Performance of Strengthened, Reinforced Concrete Shear Walls with Opening
    Mamdouh, Hala
    Zenhom, Nasr
    Hasabo, Mahmoud
    Deifalla, Ahmed Farouk
    Salman, Amany
    [J]. SUSTAINABILITY, 2022, 14 (21)
  • [49] Hysteretic performance of reinforced concrete cavity shear walls
    Xu, Gang
    Li, Aiqun
    [J]. Structural Concrete, 2020, 21 (02): : 610 - 624
  • [50] 08.39: Experimental investigations on performance enhancement of composite steel concrete shear walls by using steel fibre reinforced concrete
    Politehnica University Timisoara, Faculty of Civil Engineering, Romania
    不详
    [J]. ce/Pap., 2-3 (2157-2165):