Direct Feedback during Insertion of the Cochlear Implant Electrode

被引:0
|
作者
Kessing, Richard
机构
关键词
D O I
10.1055/a-2331-4536
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Real-time visualization of intraoperative electrocochleographic potentials (ECochG) via the picture-in-picture function of digital microscopes during cochlear implantation enables intraoperative monitoring of hearing preservation during electrode insertion. The aim of the present study was to obtain long-term data for the visualization of intraoperative ECochGs with a focus on residual hearing preservation and speech understanding.
引用
收藏
页码:629 / 630
页数:2
相关论文
共 50 条
  • [41] Measurement and Analysis of Feedback and Nonlinearities for the Codacs Direct Acoustic Cochlear Implant
    Bernardi, Giuliano
    Van Waterschoot, Toon
    Moonen, Marc
    Wouters, Jan
    Martin, Hillbart
    Verhaert, Nicolas
    IEEE ACCESS, 2017, 5 : 8702 - 8713
  • [42] Considerations for design of future cochlear implant electrode arrays: Electrode array stiffness, size, and depth of insertion
    Rebscher, Stephen J.
    Hetherington, Alexander
    Bonham, Ben
    Wardrop, Peter
    Whinney, David
    Leake, Patricia A.
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2008, 45 (05): : 731 - 747
  • [43] Implications from cochlear implant insertion for cochlear mechanics
    Kaufmann-Yehezkely, Michal
    Perez, Ronen
    Sohmer, Haim
    COCHLEAR IMPLANTS INTERNATIONAL, 2020, 21 (05) : 292 - 294
  • [44] Design of a Cochlear Implant Electrode
    Dhanasingh, Anandhan
    ENT UPDATES, 2022, 12 (02): : 97 - 109
  • [45] MULTIPLE ELECTRODE COCHLEAR IMPLANT
    CLARK, GM
    TONG, YC
    BLACK, R
    FORSTER, IC
    PATRICK, JF
    DEWHURST, DJ
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 1977, 91 (11): : 935 - 945
  • [46] Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode
    Jiseon Oh
    Jung-Eun Cheon
    Junghoan Park
    Young Hun Choi
    Yeon Jin Cho
    Seunghyun Lee
    Seung Ha Oh
    Su-Mi Shin
    Sun-Won Park
    European Radiology, 2021, 31 : 1260 - 1267
  • [47] Cochlear duct length and cochlear distance on preoperative CT: imaging markers for estimating insertion depth angle of cochlear implant electrode
    Oh, Jiseon
    Cheon, Jung-Eun
    Park, Junghoan
    Choi, Young Hun
    Cho, Yeon Jin
    Lee, Seunghyun
    Ha Oh, Seung
    Shin, Su-Mi
    Park, Sun-Won
    EUROPEAN RADIOLOGY, 2021, 31 (03) : 1260 - 1267
  • [48] New window for cochlear implant insertion
    Colletti, V
    Fiorino, FG
    ACTA OTO-LARYNGOLOGICA, 1999, 119 (02) : 214 - 218
  • [49] Optimal Cochlear Implant Insertion Vectors
    Meshik, Xenia
    Holden, Timothy A.
    Chole, Richard A.
    Hullar, Timothy E.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (01) : 58 - 63
  • [50] Cochlear Implant Insertion with a Mechatronic Tool
    Nguyen, Y.
    Miroir, M.
    Kazmitcheff, G.
    Bernardeschi, D.
    Sterkers, O.
    E-MEMOIRES DE L ACADEMIE NATIONALE DE CHIRURGIE, 2014, 13 (03): : 5 - 11