Development and evaluation of a lateral flow-based portable optical system for determination of the pregnancy status of dairy cows

被引:2
|
作者
Rial, C. [1 ]
Hussain, I. [2 ]
Hoff, R. [2 ]
Tompkins, S. [1 ]
Erickson, D. [2 ]
Branen, J. [3 ]
Giordano, J. O. [1 ]
机构
[1] Cornell Univ, Dept Anim Sci, Ithaca, NY 14853 USA
[2] Cornell Univ, Sibley Sch Mech & Aerosp Engn, Ithaca, NY 14850 USA
[3] BioTracking LLC, Moscow, ID 83843 USA
基金
美国食品与农业研究所;
关键词
lateral flow immunoassay; PSPB; pregnancy; LATE EMBRYONIC MORTALITY; TRANSRECTAL ULTRASONOGRAPHY; REPRODUCTIVE-PERFORMANCE; GLYCOPROTEINS PAG; HOLSTEIN COWS; DIAGNOSIS; RESYNCHRONIZATION; SERUM; INDUCTION; ACCURACY;
D O I
10.3168/jds.2024-24899
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
Our objectives were to develop and evaluate an integrated system consisting of a lateral flow immunoassay (LFIA) and an electronic portable imaging device for determination of pregnancy status of cows based on plasma concentrations of pregnancy-specific protein B (PSPB). Experiment 1 was conducted to test the performance of the LFIA for PSPB (PSPB-LFIA), whereas experiment 2 was conducted to evaluate the performance of the integrated system, including both the LFIA and imaging device. The PSPB-LFIA strips were made of nitrocellulose membrane with polystreptavidin, anti-mouse antibody, europium anti-PSPB conjugates, and biotin PSPB. After adding buffer and plasma in a 96-well plate, strips were dipped to initiate flow and were read in a fluorescence microscope to estimate PSPB concentrations based on the test-to-control line signal (T/C ratio). The T/C ratio of standards was linearly associated with PSPB (R-2 = 0.99 in both experiments) concentrations. To test the ability to identify pregnant cows of the PSPB-LFIA only or the integrated system, plasma samples were collected and transrectal ultrasonography (TUS) was conducted 29 to 35 d after AI in lactating Holstein cows (experiment 1: n = 83; experiment 2: n = 205). A cow was considered pregnant (Preg) if concentrations of PSPB in plasma obtained by ELISA were >= 2 ng/mL or if an embryo was visible by TUS. In experiment 1, the accuracy of the PSPB-LFIA compared with ELISA was 92.7% (91.2% sensitivity [Se]; 96.1% specificity [Sp]; 98.1% positive predictive value [PPV]; 83.3% negative predictive value [NPV]) and compared with TUS was 90.4% (100% Se; 78.9% Sp; 84.9% PPV; 100% NPV). The agreement between LFIA and ELISA (kappa = 0.84; 95% CI 0.71-0.96) or LFIA and TUS (kappa = 0.80; 95% CI 0.67-0.93) as methods to classify cows as Preg or nonpregnant (Non-Preg) was high. In experiment 2, the accuracy of the PSPB-LFIA compared with ELISA was 96.1% (93.8% Se; 100% Sp; 100% PPV; 90.5% NPV) and compared with TUS was 92.2% (99.0% Se; 84.7% Sp; 87.6% PPV; 98.8% NPV). The agreement between LFIA and ELISA (kappa = 0.92; 95% CI 0.86-0.97) or LFIA and TUS (kappa = 0.84; 95% CI 0.77-0.92) as methods to classify cows as Preg or Non-Preg was high. We conclude that a system integrating a fluorescence-based LFIA and an optical reader was effective for classifying cows as pregnant or not pregnant based on estimations of plasma concentrations of PSPB. This novel system serves as a platform for further development of on-farm pregnancy testing tools based on measurement of biomarkers of pregnancy in bodily fluids of cattle.
引用
收藏
页码:8642 / 8653
页数:12
相关论文
共 50 条
  • [21] A multisyringe flow-based system for kinetic-catalytic determination of cobalt(II)
    Chaparro, Laura
    Ferrer, Laura
    Leal, Luz
    Cerda, Victor
    TALANTA, 2015, 133 : 94 - 99
  • [22] A Robust Flow-Based System for the Spectrophotometric Determination of Cr(VI) in Recreational Waters
    Ribas, Tania C. F.
    Mesquita, Raquel B. R.
    Machado, Ana
    Miranda, Joana L. A.
    Marshall, Graham
    Bordalo, Adriano
    Rangel, Antonio O. S. S.
    MOLECULES, 2022, 27 (07):
  • [23] Determination of Minoxidil by Bleaching the Permanganate Carrier Solution in a Flow-Based Spectrophotometric System
    de Sousa, Rogerio Adelino
    Semaan, Felipe Silva
    Cervini, Priscila
    Gomes Cavalheiro, Eder Tadeu
    ANALYTICAL LETTERS, 2011, 44 (1-3) : 349 - 359
  • [24] Comparison of a lateral flow milk progesterone test with enzyme immunoassay as an aid for reproductive status determination in cows
    Waldmann, A.
    Raud, A.
    VETERINARY RECORD, 2016, 178 (11) : 260
  • [25] Development of a flow-based planning support system based on open data for the City of Atlanta
    Zhang, Ge
    Zhang, Wenwen
    Guhathakurta, Subhrajit
    Botchwey, Nisha
    ENVIRONMENT AND PLANNING B-URBAN ANALYTICS AND CITY SCIENCE, 2019, 46 (02) : 207 - 224
  • [26] Development of a milk-based lateral flow test for pregnancy diagnosis
    Krebs, T.
    Wiedemann, I.
    Blaschka, C.
    Lenz, C.
    Hennies, M.
    Kleinhans, S.
    Muetze, K.
    Knipper, K.
    Knorr, C.
    Tetens, J.
    REPRODUCTION IN DOMESTIC ANIMALS, 2019, 54 : 3 - 3
  • [27] A multicommuted flow-based system for hydrogen peroxide determination by chemiluminescence detection using a photodiode
    Leite, Oldair D.
    Fatibello-Filho, Orlando
    Vieira, Heberth J.
    Rocha, Fabio R. P.
    de Miranda Cury, Newton Sa
    ANALYTICAL LETTERS, 2007, 40 (16-18) : 3148 - 3157
  • [28] Evaluation of automatic milking system variables in dairy cows with different levels of lactation stage and reproduction status
    Juozaitiene, Vida
    Juozaitis, Arunas
    Zymantiene, Judita
    Spancerniene, Ugne
    Antanaitis, Ramunas
    Zilaitis, Vytuolis
    Tusas, Saulius
    Yilmaz, Ayhan
    JOURNAL OF DAIRY RESEARCH, 2019, 86 (04) : 410 - 415
  • [29] A new hierarchical symmetric optical flow-based image registration method and its clinical evaluation
    Michalski, D.
    Huq, H.
    Heron, D. E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S616 - S616
  • [30] Pregnancy status determination in mares using a rapid lateral flow test for measuring serum oestrone sulphate
    Henderson, KM
    Eayrs, K
    NEW ZEALAND VETERINARY JOURNAL, 2004, 52 (04) : 193 - 196