Robust model-based control and stability analysis of PMSM drive with DC-link voltage and parameter variations

被引:0
|
作者
Mehrasa, Majid [1 ]
Gholinezhadomran, Hamidreza [2 ]
Tarassodi, Pouya [2 ]
Rodrigues, Eduardo M. G. [3 ,4 ]
Salehfar, Hossein [5 ]
机构
[1] Calif State Univ Sacramento, Dept Elect & Elect Engn, Sacramento, CA USA
[2] Innvotek Ltd, Birmingham, England
[3] INESC ID, Sustainable Power Syst Grp, Ave Rovisco Pais 1, P-1049001 Lisbon, Portugal
[4] Univ Lisbon, Inst Super Tecn, Ave Rovisco Pais 1, P-1049001 Lisbon, Portugal
[5] Univ North Dakota, Sch Elect Engn & Comp Sci, Grand Forks, ND USA
来源
关键词
Permanent Magnet Synchronous Motor; (PMSM); Drive; DC link voltage and parameter variations; Stator currents; Compensators; General Operation Curve (GOC); Stability analysis; MAGNET SYNCHRONOUS MOTOR; PREDICTIVE CONTROL; CONTROL STRATEGY; TORQUE; OBSERVER; COMPENSATION; MINIMIZATION; DESIGN; SYSTEM;
D O I
10.1016/j.rico.2024.100469
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
To ensure a stable operation of Permanent Magnet Synchronous Motor (PMSM) drive under both DC link voltage and parameter variations, a robust control technique based on a new dynamic model that includes both drive's and motor's specifications is proposed in this paper. In the proposed controller, the first component of the drive's control law consists of the d-component error of the stator current, and the second one is shaped based on the error in the square value of q-component of the stator current. To further deal with the dynamic alterations of the drive system, compensators are designed to reduce the adverse effects of rotor angular frequency variations and the difference between electrical and load torque errors. Another compensator based on the drive's output power error is also placed at the q-component of the proposed control law. Moreover, a general operation curve (GOC) for the stator current is introduced to further assess the operation of the PMSM. In the next step, a comprehensive stability analysis verifying the stable operation of both d- and q-components of the stator current is performed using two closed-loop descriptions of the proposed control strategy. Several simulation results in MATLAB/SIMULINK environment are provided to verify the validity of the proposed control technique under various dynamic scenarios. It is worth mentioning that comparative results show that the proposed control technique compared to conventional PI controller has enabled the PMSM speed and torque to reach its 50% and 95% of their desirable values with respectively 42.9% and 28.6% less time. Also, the PMSM speed and torque responses due to proposed control technique have 75% less undershoot compared to conventional PI controller.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] A Robust Control for D-STATCOM Under Variations of DC-Link Capacitance
    Hashemzadeh, Ehsan
    Khederzadeh, Mojtaba
    Aghamohammadi, Mohammad Reza
    Asadi, Mehdi
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (07) : 8325 - 8333
  • [22] Low Cost Simple Look-Up Table-Based PMSM Drive Considering DC-Link Voltage Variation
    Kim, Do-Yun
    Lee, Jung-Hyo
    ENERGIES, 2020, 13 (15)
  • [23] An Effective Control Strategy Based on DC-link Voltage Regulation for an Electrolytic Capacitor less IPMSM Drive
    Khan, Muhammad Faisal
    Li, Wei
    Gao, Qiang
    2018 21ST INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS), 2018, : 1246 - 1251
  • [24] DC-Link Voltage Constraint Strategy for DC Power Supply Film-Capacitor Drive System Based on Improved Model Predictive Control
    Zhang, Zhenrui
    Guo, Haohao
    Liu, Yancheng
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (10) : 9849 - 9859
  • [25] Influence of DC-link Voltage Measurement Error on Extended EMF Based Sensorless Control with Reduced DC-Link Capacitor
    Yan, Jun
    Wu, Ximeng
    Zhu, Z. Q.
    Liu, Chaohui
    2022 25TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2022), 2022,
  • [26] A Model-Based Strategy With Robust Parameter Mismatch for Online HRC Diagnosis and Location in PMSM Drive System
    Hang, Jun
    Zhang, Jibo
    Ding, Shichuan
    Huang, Yourui
    Wang, Qunjing
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (10) : 10917 - 10929
  • [27] Analysis of Open-Loop Model-Based Sensorless Control of PMSM Drive
    Janous, Stepan
    Peroutka, Zdenek
    2012 INTERNATIONAL CONFERENCE ON APPLIED ELECTRONICS, 2012, : 123 - 126
  • [28] Transient Stability Analysis and Improved Control Strategy for DC-Link Voltage of DFIG-Based WT During LVRT
    Chen, Shiyue
    Yao, Jun
    Pei, Jinxin
    Liu, Yuan
    Liu, Ruikuo
    Huang, Sen
    Chen, Zhaoyang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2022, 37 (02) : 880 - 891
  • [29] Single DC-Link Current Sensor Control of PMSM Based on Discrete Space Vector Modulation Model Predictive Control
    Liu, Peng
    Zong, Nailong
    Yin, Zhicheng
    Liu, Liwei
    Tian, Lisi
    Deng, Xianming
    IEEE ACCESS, 2025, 13 : 46763 - 46772
  • [30] Adaptive DC-Link Voltage Control for Shunt Active Power Filters Based on Model Predictive Control
    Zhou, Juan
    Yuan, Yalei
    Dong, Hao
    IEEE ACCESS, 2020, 8 (08): : 208348 - 208357