Numerical simulation of dust deposition characteristics of photovoltaic arrays taking into account the effect of the row spacing of photovoltaic modules

被引:3
|
作者
Zheng, Chuanxiao [1 ]
Lu, Hao [1 ,2 ]
Zhao, Wenjun [2 ]
机构
[1] Xinjiang Univ, Engn Res Ctr Northwest Energy Carbon Neutral, Minist Educ, Urumqi 830047, Peoples R China
[2] Xinjiang Univ, Ctr New Energy Res, Sch Intelligent Sci & Technol, Sch Future Technol, Urumqi 830047, Peoples R China
基金
中国国家自然科学基金;
关键词
Photovoltaic array; Dust deposition; Inlet wind speed; PV module spacing; Tilt angles; Dust particle counts; IMPACT; PANELS; EFFICIENCY; POLLUTION; ENERGY;
D O I
10.1016/j.solener.2024.112804
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Dust deposition on the surfaces of Photovoltaic (PV) arrays during their operation markedly affects their power generation efficiency. Previous research has overlooked the impact of the row spacing of PV modules on the actual dust deposition on PV arrays. This study investigates the dust deposition process and its behavior on PV arrays considering variations in row spacings, inlet wind speeds, dust particle sizes, and dust particle counts. By employing commercial Computational Fluid Dynamics (CFD) software, incorporating the SST k - omega turbulence model and discrete particle model, numerical simulations were performed to analyze the airflow field, dust particle trajectories, dust deposition patterns, and deposition rates on the PV array through grid-independent verification and numerical validation. At the same time, we performed a comparative analysis of the deposition rate considering the rebound of dust particles on the PV module surface versus the case where rebound is not considered. Results revealed that the maximum dust deposition rates at different inlet wind speeds were 6.84 %, 8.84%, 11.0 %, and 14.6 %, corresponding to dust sizes of 50 mu m, 100 mu m, 120 mu m, and 300 mu m, respectively. Smaller dust particles exhibited lower deposition rates, while larger particles were influenced more by mass inertia and gravity, leading to predominant deposition on the front row of PV modules. Larger dust particles are more likely to deposit primarily on the front row of PV modules in a PV array. The tilt angles of 30 degrees, 45 degrees, and 60 degrees were chosen to study the effects of different tilt angles on the dust deposition of PV arrays, and the results show that the dust deposition rate decreases as the tilt angle increases, and it is worth noting that the larger the tilt angle, the larger the dust deposition rate is when the dust particles are especially small as 5 mu m. When wind speeds are low and dust particles are small, the dust deposition rate gradually rises as the row spacing increases. However, at higher wind speeds with small dust particles, the row spacing has minimal impact on the dust deposition rate. Conversely, with larger dust particles, increasing the row spacing results in a lower dust deposition rate. These findings underscore the significance of optimizing PV array design for enhanced power generation efficiency.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Effect of Sand and Dust Shading on the Output Characteristics of Solar Photovoltaic Modules in Desertification Areas
    Zhao, Mingzhi
    Yu, Rong
    Chang, Chun
    Bao, Daorina
    Mei, Aohan
    Liu, Yingjie
    Wang, Ningbo
    ENERGIES, 2023, 16 (23)
  • [32] Effect of Dust Deposition on the Performance of Multi-Crystalline Photovoltaic Modules Based on Experimental Measurements
    Kazem, Hussein A.
    Khatib, Tamer
    Sopian, K.
    Buttinger, Frank
    Elmenreich, Wilfried
    Albusaidi, Ahmed Said
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2013, 3 (04): : 850 - 853
  • [33] Prediction of thermal boundary layer thickness and bidirectional effect of dust deposition on the output of photovoltaic modules
    Guo, Xiao
    Li, Jinping
    Tian, Rui
    Qiu, Yunfeng
    Li, Xiaoxia
    Yang, Junling
    Gao, Chonggang
    SOLAR ENERGY, 2024, 268
  • [34] In-situ Investigation the Effect of Dust Deposition on the polycrystalline silicon photovoltaic modules in Ouargla region
    Narimane, Khelfaoui
    Ahmed, Djafour
    Khadidja, Bouali
    Bilal, Danoune M.
    Halima, Boutelli
    Gougui, Abdelmoumen
    2018 INTERNATIONAL CONFERENCE ON COMMUNICATIONS AND ELECTRICAL ENGINEERING (ICCEE), 2018, : 108 - 112
  • [35] Numerical simulation of dust deposition on rooftop of photovoltaic parking lots supporting electric vehicles charging
    Abdolahzadeh, Mohsen
    Mofrad, Nima Parsa
    Tayebi, Ali
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2023, 239
  • [36] The effect of dust with different morphologies on the performance degradation of photovoltaic modules
    Tanesab, Julius
    Parlevliet, David
    Whale, Jonathan
    Urmee, Tania
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2019, 31 : 347 - 354
  • [37] Experimental Study on the Effect of Dust Deposition on Photovoltaic Panels
    Chen, Yingya
    Liu, Yanfeng
    Tian, Zhijun
    Dong, Yu
    Zhou, Yong
    Wang, Xiaowen
    Wang, Dengjia
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 483 - 489
  • [38] Effect of Accumulated Dust Conductivity on Leakage Current of Photovoltaic Modules
    Gao, Yu
    Guo, Fei
    Tian, Haibo
    Xue, Mengyuan
    Jin, Yaoyang
    Wang, Baomiao
    ENERGIES, 2024, 17 (13)
  • [39] Effect of dust accumulation on the power outputs of solar photovoltaic modules
    Adinoyi, Muhammed J.
    Said, Syed A. M.
    RENEWABLE ENERGY, 2013, 60 : 633 - 636
  • [40] Numerical investigations of the characteristics of the operation of solar photovoltaic modules taking into account the variability of the external impact factors characteristic of piedmont areas. Part i
    Zakhidov R.A.
    Kiseleva E.I.
    Orlova N.I.
    Tadjiev U.A.
    Applied Solar Energy, 2010, 46 (2) : 145 - 151