Surgical Outcomes of a Human Umbilical Cord Allograft Over the Ahmed Glaucoma Valve Plate for Refractory Glaucoma

被引:0
|
作者
Rao, Aparna [1 ]
机构
[1] L V Prasad Eye Inst, Glaucoma, Kallam Anji Reddy Campus, Hyderabad, India
关键词
allograft; fibrosis; wound healing; umbilical cord; ahmed glaucoma valve; HYPERTENSIVE PHASE; AMNIOTIC MEMBRANE; MITOMYCIN-C; EYE DROPS; IMPLANTATION;
D O I
10.7759/cureus.67923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To report the surgical outcomes of sterile dehydrated human umbilical cord allograft over the Ahmed glaucoma valve (AGV) plate for refractory glaucoma. Methods: Thirty-four eyes of 34 patients with refractory glaucoma who underwent AGV with umbilical cord allograft (AmnioPlast THICKTM; Life Cell International Private Limited, Mumbai, India) placed over the AGV plate between September 2021 and 2022 at a tertiary eye care centre were included (group1) and compared with 30 eyes of 30 patients undergoing AGV without amnioblasts (group 2). The intraocular pressure (IOP) at day one, one month, six months, and final IOP; the necessity for medications; or additional surgeries for IOP control were extracted from the hospital database. Success was defined as achieving an IOP below 22 mm Hg with or without glaucoma medications. IOP spikes after surgery were identified as a rise in pressure beyond 22 mm Hg at any point beyond six weeks post-surgery following an initial reduction of pressure exceeding 30% from the baseline pre-surgical IOP. Results: A notable reduction in intraocular pressure (37 +/- 7.9 mm Hg preoperative versus 14 +/- 3.7 mm Hg at the final follow-up and 28 +/- 3.6 mm Hg versus 18 +/- 6.7 mm Hg in group 1 and 2, respectively) was observed in all eyes, with successful outcomes observed in 23 out of 34 eyes (67%). Ten eyes experienced a pressure spike, occurring at a median time of 12 months (range: 6-18 months), predominantly beyond six months post-surgery in group 1, while group 2 had similar pressure spikes in 21 of 30 eyes at a median time of two months (range: 1-5 months). No eyes necessitated supplementary glaucoma procedures, concluding with a final IOP of 14 +/- 3.7 mm Hg at 1.9 +/- 0.8 years. Vision loss occurred in only one of the 11 eyes that failed owing to non-glaucoma-related causes in group 1. Conclusions: The human umbilical cord allograft plate over the AGV plate may help in postponing the onset of intraocular pressure spikes beyond traditionally defined timelines. This helps in reducing and delaying the hypertensive phase occurring due to fibrosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Surgical outcomes of Ahmed glaucoma valve implantation in patients with glaucoma secondary to iridocorneal endothelial syndrome
    Mao, Zhen
    Guo, Xinxing
    Zhong, Yimin
    Liu, Xing
    EYE, 2021, 35 (02) : 608 - 615
  • [42] Surgical outcomes of Ahmed glaucoma valve implantation in patients with glaucoma secondary to iridocorneal endothelial syndrome
    Zhen Mao
    Xinxing Guo
    Yimin Zhong
    Xing Liu
    Eye, 2021, 35 : 608 - 615
  • [43] Outcomes of Ahmed glaucoma valve implantation in advanced primary congenital glaucoma with previous surgical failure
    Huang, Jingjing
    Lin, Jialiu
    Wu, Ziqiang
    Xu, Hongzhi
    Zuo, Chengguo
    Ge, Jian
    CLINICAL OPHTHALMOLOGY, 2015, 9 : 977 - 983
  • [44] Long-Term Outcomes of Ahmed Glaucoma Valve Surgery in a Scottish Cohort of Patients With Refractory Glaucoma
    Siempis, Thomas
    Younus, Osman
    Makuloluwa, Achini
    Montgomery, Donald
    Croghan, Catherine
    Sidiki, Sikander
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (03)
  • [45] Comparision of surgical outcomes of Express Shunt and Ahmed Valve in Neovascular Glaucoma
    Kadikoy, Huseyin
    Hughes, Bret
    Tannir, Justin
    Momi, Rominder
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [46] Surgical outcomes of the Aurolab aqueous drainage implant (AADI) versus the Ahmed glaucoma valve for refractory paediatric glaucoma in Middle Eastern children
    Khan, Abdullah M.
    Ahmad, Khabir
    Alarfaj, Motazz
    Alotaibi, Humoud
    AlJaloud, Ahmad
    Malik, Rizwan
    BMJ OPEN OPHTHALMOLOGY, 2021, 6 (01):
  • [47] A Novel Surgical Technique for Ahmed Glaucoma Valve Implantation Without Plate Sutures
    Sanvicente, Carina T.
    Moster, Marlene R.
    Lee, Daniel
    Menezes, Alicia
    Ghahramani, Aria
    Zhang, Qiang
    Hamershock, Rose
    Myers, Jonathan S.
    JOURNAL OF GLAUCOMA, 2020, 29 (03) : 161 - 167
  • [48] THE EFFECT OF ADJUVANT MITOMYCIN C IN AHMED GLAUCOMA VALVE SURGERY FOR REFRACTORY GLAUCOMA
    Tien, Melissa
    Yip, Leonard
    Wong, Elizabeth Poh Ying
    Yong, Vernon
    Wong, Hon Tym
    Lim, Boon Ang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [49] Long-term outcomes of Ahmed glaucoma valve implantation in refractory glaucomas
    Souza, Carlos
    Tran, Duc H.
    Loman, Jane
    Law, Simon K.
    Coleman, Anne L.
    Caprioli, Joseph
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (06) : 893 - 900
  • [50] Outcomes of Ahmed Glaucoma Valve Implantation in Children With Primary Congenital Glaucoma
    Ou, Yvonne
    Yu, Fei
    Law, Simon K.
    Coleman, Anne L.
    Caprioli, Joseph