Surgical Outcomes of a Human Umbilical Cord Allograft Over the Ahmed Glaucoma Valve Plate for Refractory Glaucoma

被引:0
|
作者
Rao, Aparna [1 ]
机构
[1] L V Prasad Eye Inst, Glaucoma, Kallam Anji Reddy Campus, Hyderabad, India
关键词
allograft; fibrosis; wound healing; umbilical cord; ahmed glaucoma valve; HYPERTENSIVE PHASE; AMNIOTIC MEMBRANE; MITOMYCIN-C; EYE DROPS; IMPLANTATION;
D O I
10.7759/cureus.67923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: To report the surgical outcomes of sterile dehydrated human umbilical cord allograft over the Ahmed glaucoma valve (AGV) plate for refractory glaucoma. Methods: Thirty-four eyes of 34 patients with refractory glaucoma who underwent AGV with umbilical cord allograft (AmnioPlast THICKTM; Life Cell International Private Limited, Mumbai, India) placed over the AGV plate between September 2021 and 2022 at a tertiary eye care centre were included (group1) and compared with 30 eyes of 30 patients undergoing AGV without amnioblasts (group 2). The intraocular pressure (IOP) at day one, one month, six months, and final IOP; the necessity for medications; or additional surgeries for IOP control were extracted from the hospital database. Success was defined as achieving an IOP below 22 mm Hg with or without glaucoma medications. IOP spikes after surgery were identified as a rise in pressure beyond 22 mm Hg at any point beyond six weeks post-surgery following an initial reduction of pressure exceeding 30% from the baseline pre-surgical IOP. Results: A notable reduction in intraocular pressure (37 +/- 7.9 mm Hg preoperative versus 14 +/- 3.7 mm Hg at the final follow-up and 28 +/- 3.6 mm Hg versus 18 +/- 6.7 mm Hg in group 1 and 2, respectively) was observed in all eyes, with successful outcomes observed in 23 out of 34 eyes (67%). Ten eyes experienced a pressure spike, occurring at a median time of 12 months (range: 6-18 months), predominantly beyond six months post-surgery in group 1, while group 2 had similar pressure spikes in 21 of 30 eyes at a median time of two months (range: 1-5 months). No eyes necessitated supplementary glaucoma procedures, concluding with a final IOP of 14 +/- 3.7 mm Hg at 1.9 +/- 0.8 years. Vision loss occurred in only one of the 11 eyes that failed owing to non-glaucoma-related causes in group 1. Conclusions: The human umbilical cord allograft plate over the AGV plate may help in postponing the onset of intraocular pressure spikes beyond traditionally defined timelines. This helps in reducing and delaying the hypertensive phase occurring due to fibrosis.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Surgical Outcomes of Additional Ahmed Glaucoma Valve Implantation in Refractory Glaucoma
    Ko, Sung Ju
    Hwang, Young Hoon
    Ahn, Sang Il
    Kim, Hwang Ki
    JOURNAL OF GLAUCOMA, 2016, 25 (06) : E620 - E624
  • [2] Surgical Outcomes of a Second Ahmed Glaucoma Valve Implant for the Treatment of Refractory Glaucoma
    Becerril-Cazadero, Roxana
    Seibold, Leonard K.
    Turati-Acosta, Mauricio
    Jimenez-Roman, Jesus
    Fabre-Miranda, Karina
    Han, Ying
    Lazcano-Gomez, Gabriel
    JOURNAL OF GLAUCOMA, 2020, 29 (10) : 948 - 951
  • [3] Surgical Outcomes of a Second Ahmed Glaucoma Valve Implantation in Asian Eyes with Refractory Glaucoma
    Ong, Sze Chuan
    Aquino, Maria Cecilia
    Chew, Paul
    Koh, Victor
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [4] Ahmed glaucoma valve in various etiologies of refractory glaucoma: Surgical outcomes and success factors
    Sahyoun, M. A.
    Farhat, R. G.
    Nehme, J. C. B.
    Jalkh, A. E.
    Azar, G. G.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2017, 40 (09): : 770 - 776
  • [5] Outcomes of Ahmed glaucoma valve implantationTM in refractory pediatric glaucoma
    Senthil, Sirisha
    Dave, Paaraj
    Roy, Avik
    Rao, Harsha
    Mandal, Anil K.
    Garudadri, Chandra S.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [6] Outcomes of Silicone Ahmed Glaucoma Valve Implantation in Refractory Pediatric Glaucoma
    Senthil, Sirisha
    Turaga, Kiranmaye
    Mohammed, Hasnat A.
    Krishnamurthy, Rashmi
    Badakere, Swathi
    Dikshit, Siddharth
    Choudhari, Nikhil
    Mandal, Anil K.
    Garudadri, Chandra S.
    JOURNAL OF GLAUCOMA, 2018, 27 (09) : 769 - 775
  • [7] Long-term surgical outcomes of Ahmed valve implantation in refractory glaucoma according to the type of glaucoma
    Yong Koo Kang
    Jae Pil Shin
    Dai Woo Kim
    BMC Ophthalmology, 22
  • [8] Long-term surgical outcomes of Ahmed valve implantation in refractory glaucoma according to the type of glaucoma
    Kang, Yong Koo
    Shin, Jae Pil
    Kim, Dai Woo
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [9] A comparison of the polypropylene plate Ahmed™ glaucoma valve to the silicone plate Ahmed™ glaucoma flexible valve
    Hinkle, D. M.
    Zlirakoinski, D.
    Ayyala, R. S.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2007, 17 (05) : 696 - 701
  • [10] Ahmed Glaucoma Valve in Refractory Glaucoma: A Retrospective Study
    Kumar, Suresh
    Thakur, Sahil
    Sharma, Madhu
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2018, 12 (04) : NC8 - NC11