Detection of explosives residue using a novel subsampling technique for DART-HRMS analysis

被引:1
|
作者
Estevanes, Jared [1 ]
Couch, Alleigh N. [1 ]
Bates, Kevin [2 ]
Monjardez, Geraldine [1 ]
Davidson, J. Tyler [1 ]
机构
[1] Sam Houston State Univ, Coll Criminal Justice, Dept Forens Sci, Huntsville, TX 77340 USA
[2] Montgomery Cty Fire Marshals Off, Conroe, TX USA
关键词
Forensic science; Trace evidence; Explosive residues; Direct analysis in real time-mass spectrometry; (DART-MS); Sampling technique; Detonation; REAL-TIME; SPECTROMETRY;
D O I
10.1016/j.forc.2024.100585
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the ensuing investigation after an explosion, determining the explosive used is of prime importance to establish investigative leads. Post-blast samples have many interferences and considerations that make quick, reliable identification a challenge. The use of a novel subsampling technique with DART-HRMS provides the ability to quickly detect and identify explosive residue after detonation. Simulated improvised explosive devices were constructed with a variety of materials and detonated with the help of the Montgomery County Fire Marshal's Office (TX). Post-blast debris was subsequently collected and swabbed with a novel subsampling technique, utilizing filter paper. This filter paper was then introduced into the DART gas stream, with an internal standard to minimize potential false negatives. After introducing explosive residue from swabbed post-blast substrates, characteristic ions of selected constituents of smokeless powder including diphenylamine, ethyl centralite, di-n-butyl phthalate, and nitroglycerin were detected and confirmed through comparison of accurate mass measurements to theoretical exact masses. Additionally, characteristic ions of 2,4,6-trinitrotoluene (TNT) and Royal Demolition eXplosive (RDX) were also detected using this technique. Overall, the detection of characteristic ions was more successful when recovering residue from plastic compared to wood or metal, with success rates routinely at 100%. Implementing this screening technique enables rapid detection and reliable identification of explosive residue in a detonation incident. The developed subsampling technique provides practitioners with a practical method of screening post-blast debris in a laboratory setting, requiring minimal sample preparation.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A Novel Ultrasonic Vibration Analysis Technique for Discontinuity Detection
    Borigo, Cody
    Yan, Fei
    Liang, Yue
    Rose, Joseph L.
    MATERIALS EVALUATION, 2013, 71 (10) : 1242 - 1251
  • [42] Study of thermal decomposition mechanisms and low-level detection of explosives using pulsed photoacoustic technique
    F. Yehya
    A. K. Chaudhary
    D. Srinivas
    K. Muralidharan
    Applied Physics B, 2015, 121 : 193 - 202
  • [43] Study of thermal decomposition mechanisms and low-level detection of explosives using pulsed photoacoustic technique
    Yehya, F.
    Chaudhary, A. K.
    Srinivas, D.
    Muralidharan, K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2015, 121 (02): : 193 - 202
  • [45] Novel Blind Video Forgery Detection Using Markov Models on Motion Residue
    Kancherla, Kesav
    Mukkamala, Srinivas
    INTELLIGENT INFORMATION AND DATABASE SYSTEMS (ACIIDS 2012), PT III, 2012, 7198 : 308 - 315
  • [46] A novel immunoassay technique using principal component analysis for enhanced detection of emerging viral variants
    Calidonio, Josselyn Mata
    Maddox, Arianna I.
    Hamad-Schifferli, Kimberly
    LAB ON A CHIP, 2024, 24 (16) : 3985 - 3995
  • [47] Explosives Detection Using Dual Energy X-ray Imaging and Photoneutron Analysis
    Yang, Yigang
    Li, Tiezhu
    Li, Yuanjing
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 876 - +
  • [48] Text Detection and Recognition Using Enhanced MSER Detection and a Novel OCR Technique
    Islam, Md. Rabiul
    Mondal, Chayan
    Azam, Md. Kawsar
    Islam, Abu Syed Md. Jannatul
    2016 5TH INTERNATIONAL CONFERENCE ON INFORMATICS, ELECTRONICS AND VISION (ICIEV), 2016, : 15 - 20
  • [49] Chemical manipulation of explosives using novel multifunctional reagents (MFRS) for analysis by SERRS.
    McHugh, CJ
    Smith, WE
    Graham, D
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 222 : U86 - U87
  • [50] A novel approach to microcalcification detection using fuzzy logic technique
    Cheng, HD
    Lui, YM
    Freimanis, RI
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (03) : 442 - 450