High-temperature liquid chromatography-isotope ratio mass spectrometry methodology for carbon isotope ratio determination of anabolic steroids in urine

被引:0
|
作者
Honesova, Lenka [1 ]
Viaene, Wouter [1 ]
Van Eenoo, Peter [1 ]
Polet, Michael [1 ]
机构
[1] Univ Ghent, Dept Diagnost Sci, Doping Control Lab, Ottergemsesteenweg 460, B-9000 Ghent, Belgium
关键词
CHEMISTRY; SCIENCE; WATER;
D O I
10.1016/j.aca.2024.343092
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Gas Chromatography Isotope Ratio Mass Spectrometry (GC-C-IRMS) has long been used in routine laboratories to determine the delta 13 C values of anabolic steroids in urine, differentiating between, e.g., endogenous and synthetic testosterone (T) in sports doping control. Until now, liquid chromatography (LC-IRMS) has not been used. The LC-IRMS setup doesn't allow organic solvents or modifiers in the mobile phase for delta 13 C determinations. Mid-to non-polar analytes such as steroids can be analysed in water heated to High Temperatures (HT, up to 200 degrees C) because at 200 degrees C has a similar polarity as 80/20 methanol/water at ambient temperature. In this work, we developed a method for steroids in urine, extending the application of the LC-IRMS to non-polar analytes in complex matrices. Result: An HT-LC-IRMS method capable of determining the delta 13 C values of four steroids (i.e., testosterone (T), 5 alpha-androstane-3 alpha,17 beta-diol beta- diol (alpha alpha beta), beta ), 5 beta-androstane-3 alpha,17 beta- beta- androstane-3 alpha,17 beta- diol (beta alpha beta) beta alpha beta ) and pregnanetriol (PT)) in urine was developed and validated. Accuracy ranged from 0.23 %o (alpha alpha beta beta and beta alpha beta ) to 0.49 %o (T), and the detection limit was set at 10 ng mL-1-1 (T, alpha alpha beta+beta alpha beta). beta + beta alpha beta ). The validation data and a comparison of authentic urine samples analysed with HT-LC-IRMS and GC-C-IRMS indicated a comparable performance between HT-LC-IRMS and GC-C-IRMS. Significance: HT-LC-IRMS can be used to determine delta 13 C values of anabolic steroids, extending the applicability of both HT-LC and LC-IRMS to non-polar substances determined in a complex matrix in routine laboratory practice.
引用
下载
收藏
页数:7
相关论文
共 50 条
  • [21] Isotope ratio monitoring of small molecules and macromolecules by liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, JP
    Hau, J
    Fay, LB
    Hopfgartner, G
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (18) : 2689 - 2698
  • [22] Pyrolysis-gas chromatography-isotope ratio mass spectrometry of macromolecular material in meteorites
    Sephton, MA
    Gilmour, I
    PLANETARY AND SPACE SCIENCE, 2001, 49 (05) : 465 - 471
  • [23] Determination of Serum Growth Hormone by Liquid Chromatography-Isotope Dilution Mass Spectrometry
    Yu L.-X.
    Zhai R.
    Chu Z.-Y.
    Jin Y.-X.
    Wu L.-Q.
    Mi W.
    Gong X.-Y.
    Xie J.
    Jiang Y.
    Dai X.-H.
    Fang X.
    Yu X.-P.
    Journal of Chinese Mass Spectrometry Society, 2021, 42 (02) : 129 - 139
  • [24] Improved isotope ratio measurement performance in liquid chromatography/isotope ratio mass spectrometry by removing excess oxygen
    Hettmann, Elena
    Brand, Willi A.
    Gleixner, Gerd
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (24) : 4135 - 4141
  • [25] A versatile method for stable carbon isotope analysis of carbohydrates by high-performance liquid chromatography/isotope ratio mass spectrometry
    Boschker, H. T. S.
    Moerdijk-Poortvliet, T. C. W.
    van Breugel, P.
    Houtekamer, M.
    Middelburg, J. J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (23) : 3902 - 3908
  • [26] Determination of the natural abundance δ15N of taurine by gas chromatography-isotope ratio measurement mass spectrometry
    Tea, Illa
    Antheaume, Ingrid
    Besnard, Jorick
    Robins, Richard J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (23) : 3380 - 3386
  • [27] Temperature-programmed high-performance liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, Jean-Philippe
    Hopfgartner, Gerard
    Fay, Laurent
    ANALYTICAL CHEMISTRY, 2008, 80 (18) : 7144 - 7152
  • [28] Determination of carbon isotope ratios of methanol and acetaldehyde in air samples by gas chromatography-isotope ratio mass spectrometry combined with headspace solid-phase microextraction
    Yamada, Keita
    Hattori, Ryota
    Ito, Yuji
    Shibata, Hiroki
    Yoshida, Naohiro
    ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2010, 46 (03) : 392 - 399
  • [29] DETERMINATION OF URINE CREATINE, CREATININE. GUANIDINOACETATE, AND ARGININE BY LIQUID CHROMATOGRAPHY-ISOTOPE DILUTION TANDEM MASS SPECTROMETRY
    Yazdanpanah, M.
    Adeli, K.
    vonBoth, I.
    Schulze, A.
    Kyriakopoulou, G. L.
    MOLECULAR GENETICS AND METABOLISM, 2009, 98 (1-2) : 134 - 134
  • [30] Determination of selected endogenous anabolic androgenic steroids and ratios in urine by ultra high performance liquid chromatography tandem mass spectrometry and isotope pattern deconvolution
    Pitarch-Motellon, J.
    Sancho, J. V.
    Ibanez, M.
    Pozo, O.
    Roig-Navarro, A. F.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1515 : 172 - 178