Behavior of repaired heat-damaged self-compacted concrete slabs with openings using NSM-CFRP strips

被引:1
|
作者
Obaidat, Ala Taleb [1 ]
Obaidat, Yasmeen Taleb [2 ]
Ashteyat, Ahmed [3 ,4 ]
机构
[1] Philadelphia Univ, Fac Engn & Technol, Dept Civil Engn, Amman, Jordan
[2] Jordan Univ Sci & Technol, Civil Engn Dept, Irbid, Jordan
[3] Prince Sattam Bin Abdulaziz Univ, Coll Engn Al Kharj, Dept Civil Engn, Al Kharj, Saudi Arabia
[4] Univ Jordan, Fac Engn, Dept Civil Engn, Amman, Jordan
关键词
Slab with opening; Self-compacted concrete; Carbon-fiber-reinforced polymer; Heat damaged; Elevated temperature; Near-surface-mounted strip; PUNCHING SHEAR;
D O I
10.1108/IJSI-11-2023-0124
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
PurposeIn this experimental investigation, the behavior of strengthened/repaired heat-damaged one-way self-compacted concrete (SCC) slabs with opening utilizing near-surface-mounted-carbon fiber reinforced polymers (NSM-CFRP) strips was explored.Design/methodology/approachCFRP strip configurations, number of strips and inclination were all investigated in this study. For three hours, slabs were exposed to temperatures of 23 degrees C and 500 degrees C. Four-point load was applied to control slabs, enhanced slabs and repaired slabs.FindingsThe results indicate that exposing the slabs to high temperatures reduces their load capability. The number of strips and angle of inclination around the slab opening have a considerable impact on the performance of the strengthened and/or repaired slabs, according to the experimental results. The load capacity, toughness and ductility index of a strengthened and/or repaired slab with opening increase as the number of CFRP strips increases by 143.8-150.5%, 137.3-149.9% and 122.3-124.5%, respectively. The use of NSM strips around the opening with zero inclination showed higher load compared to the NSM strips around the opening with other angles.Originality/valueIt is frequently important to construct openings in the slabs for ventilation, electrical supply, and other purposes. Making openings in slabs might affect the structure's performance since the concrete and reinforcing would be cut off. SCC is a new type of concrete mixture that can fill in all the voids in the formwork with its own weight without the help of external vibration. As a result, it is necessary to reinforce the slab under flexure and increase the flexural strength of the SCC slab. Therefore, this work investigates the effect of using NSM-CFRP strip on the behavior of one way SCC slabs that have been heat-damaged.
引用
下载
收藏
页码:993 / 1011
页数:19
相关论文