A novel low-cost sensors system for real-time multipollutant indoor air quality monitoring - Development and performance

被引:0
|
作者
Chojer, H. [1 ,2 ]
Branco, P. T. B. S. [1 ,2 ]
Martins, F. G. [1 ,2 ]
Sousa, S. I. V. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, LEPABE Lab Proc Engn Environment Biotechnol & Ener, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[2] Univ Porto, Fac Engn, ALiCE Associate Lab Chem Engn, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
关键词
Indoor air quality; Air quality monitoring; Calibration; Multipollutant; Low-cost sensors; FIELD CALIBRATION; AVAILABLE SENSORS; EXPOSURE; PLATFORM; CLUSTER; PART; HOME;
D O I
10.1016/j.buildenv.2024.112055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air pollution poses a significant health risk, thus demanding effective indoor air quality (IAQ) monitoring strategies. Low-cost sensors (LCS) have gained attraction for IAQ monitoring, but their data accuracy and robustness remain key challenges. This study addresses gaps in the literature by developing and evaluating a novel low-cost monitor prototype for IAQ monitoring. A detailed design methodology based on requirements analysis was used to create two identical low-cost monitors (LCM) prototypes for multipollutant monitoring, including PM2.5, CO2, CO, O-3, NO2, temperature and relative humidity. The LCM were deployed in an in-field monitoring campaign alongside research-grade instruments. The uncorrected sensor signals showed linear response compared to research-grade instruments with high Pearson Correlation Coefficients for 1-min mean: PM2.5 (0.97), CO2 (0.81-0.89), CO (0.95-0.98), and O-3 (0.80-0.85). The concentration range of pollutants was observed to play a crucial role in the response and accuracy of the LCS. Kalman filter was implemented with optimised parameters to reduce noise from the signal of ozone sensors. Univariate and multivariate linear models were used to field calibrate the sensors. Linear regression models, with high coefficients of determination (>0.8) and low error values, imply that the developed LCM prototypes can be reliably used for indicative monitoring. In most of the cases, univariate linear models using only the sensor response of LCS as explanatory variables showed significant improvement. Future work will involve longer monitoring campaigns in different microenvironments, evaluation of calibration drift and to assess failure episodes in long-term use.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] A Low-Cost Sensor for Real-Time Monitoring of Indoor Thermal Comfort for Ambient Assisted Living
    Revel, Gian Marco
    Arnesano, Marco
    Pietroni, Filippo
    [J]. AMBIENT ASSISTED LIVING, 2014, : 3 - 12
  • [42] A Low-cost Real-time IoT based Air Pollution Monitoring using LoRa
    Walling, Supongmen
    Sengupta, Jayasree
    Das Bit, Sipra
    [J]. 13TH IEEE INTERNATIONAL CONFERENCE ON ADVANCED NETWORKS AND TELECOMMUNICATION SYSTEMS (IEEE ANTS), 2019,
  • [43] Low-Cost Internet of Things Based Real-Time Pavement Monitoring System
    Bekiroglu, Korkut
    Tekeoglu, Ali
    Shen, Jiayue
    Boz, Ilker
    [J]. IEEE CONGRESS ON CYBERMATICS / 2021 IEEE INTERNATIONAL CONFERENCES ON INTERNET OF THINGS (ITHINGS) / IEEE GREEN COMPUTING AND COMMUNICATIONS (GREENCOM) / IEEE CYBER, PHYSICAL AND SOCIAL COMPUTING (CPSCOM) / IEEE SMART DATA (SMARTDATA), 2021, : 17 - 22
  • [44] Designing a low-cost real-time group heart rate monitoring system
    Kofjac, Davorin
    Stojanovic, Radovan
    Kolozvari, Andrej
    Skraba, Andrej
    [J]. MICROPROCESSORS AND MICROSYSTEMS, 2018, 63 : 75 - 84
  • [45] Real-Time Speed Monitoring of Elevator System Based on Low-Cost IMU
    Zhang, Shuo
    Hong, Chengan
    Huang, Haiqing
    Wu, Duidi
    Zhao, Qianyou
    Qi, Jin
    Hu, Jie
    Peng, Yinghong
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (15) : 17559 - 17571
  • [46] Low-cost real-time environmental noise monitoring system design and implementation
    Hamamcı S.F.
    Doğru A.Ö.
    [J]. International Journal of Environmental Studies, 2024, 81 (03) : 1045 - 1057
  • [47] Low-Cost Stand-Alone System for Real-Time Hydrological Monitoring
    Islam, Mohammad S.
    Bonner, James S.
    Paley, James B.
    Fuller, Christopher B.
    [J]. ENVIRONMENTAL ENGINEERING SCIENCE, 2016, 33 (12) : 929 - 941
  • [48] Mapping urban air quality in near real-time using observations from low-cost sensors and model information
    Schneider, Philipp
    Castell, Nuria
    Vogt, Matthias
    Dauge, Franck R.
    Lahoz, William A.
    Bartonova, Alena
    [J]. ENVIRONMENT INTERNATIONAL, 2017, 106 : 234 - 247
  • [49] Development of a real-time monitoring and detection indoor air quality system for intensive care unit and emergency department
    Baqer, Noor S.
    Mohammed, Hussein A.
    Albahri, A. S.
    [J]. SIGNA VITAE, 2023, 19 (01) : 77 - 92
  • [50] Low-Power Wireless Sensor Network for Real-Time Indoor Air Quality Monitoring with CO2 Sensors
    Diaz, Leandro
    Azziz, Julia
    Oliver, Juan Pablo
    Veirano, Francisco
    [J]. 15TH IEEE LATIN AMERICAN SYMPOSIUM ON CIRCUITS AND SYSTEMS, LASCAS 2024, 2024, : 85 - 89