A novel low-cost sensors system for real-time multipollutant indoor air quality monitoring - Development and performance

被引:0
|
作者
Chojer, H. [1 ,2 ]
Branco, P. T. B. S. [1 ,2 ]
Martins, F. G. [1 ,2 ]
Sousa, S. I. V. [1 ,2 ]
机构
[1] Univ Porto, Fac Engn, LEPABE Lab Proc Engn Environment Biotechnol & Ener, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
[2] Univ Porto, Fac Engn, ALiCE Associate Lab Chem Engn, Rua Dr Roberto Frias, P-4200465 Porto, Portugal
关键词
Indoor air quality; Air quality monitoring; Calibration; Multipollutant; Low-cost sensors; FIELD CALIBRATION; AVAILABLE SENSORS; EXPOSURE; PLATFORM; CLUSTER; PART; HOME;
D O I
10.1016/j.buildenv.2024.112055
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air pollution poses a significant health risk, thus demanding effective indoor air quality (IAQ) monitoring strategies. Low-cost sensors (LCS) have gained attraction for IAQ monitoring, but their data accuracy and robustness remain key challenges. This study addresses gaps in the literature by developing and evaluating a novel low-cost monitor prototype for IAQ monitoring. A detailed design methodology based on requirements analysis was used to create two identical low-cost monitors (LCM) prototypes for multipollutant monitoring, including PM2.5, CO2, CO, O-3, NO2, temperature and relative humidity. The LCM were deployed in an in-field monitoring campaign alongside research-grade instruments. The uncorrected sensor signals showed linear response compared to research-grade instruments with high Pearson Correlation Coefficients for 1-min mean: PM2.5 (0.97), CO2 (0.81-0.89), CO (0.95-0.98), and O-3 (0.80-0.85). The concentration range of pollutants was observed to play a crucial role in the response and accuracy of the LCS. Kalman filter was implemented with optimised parameters to reduce noise from the signal of ozone sensors. Univariate and multivariate linear models were used to field calibrate the sensors. Linear regression models, with high coefficients of determination (>0.8) and low error values, imply that the developed LCM prototypes can be reliably used for indicative monitoring. In most of the cases, univariate linear models using only the sensor response of LCS as explanatory variables showed significant improvement. Future work will involve longer monitoring campaigns in different microenvironments, evaluation of calibration drift and to assess failure episodes in long-term use.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Using low-cost sensors to assess real-time comfort and air quality patterns in indoor households
    Johnny Reis
    Diogo Lopes
    Daniel Graça
    Ana Patrícia Fernandes
    Ana Isabel Miranda
    Myriam Lopes
    [J]. Environmental Science and Pollution Research, 2023, 30 : 7736 - 7751
  • [2] Using low-cost sensors to assess real-time comfort and air quality patterns in indoor households
    Reis, Johnny
    Lopes, Diogo
    Graca, Daniel
    Fernandes, Ana Patricia
    Miranda, Ana Isabel
    Lopes, Myriam
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (03) : 7736 - 7751
  • [3] Review of the Performance of Low-Cost Sensors for Air Quality Monitoring
    Karagulian, Federico
    Barbiere, Maurizio
    Kotsev, Alexander
    Spinelle, Laurent
    Gerboles, Michel
    Lagler, Friedrich
    Redon, Nathalie
    Crunaire, Sabine
    Borowiak, Annette
    [J]. ATMOSPHERE, 2019, 10 (09)
  • [4] Development and validation of a low-cost infrared measurement system for real-time monitoring of indoor thermal comfort
    Revel, G. M.
    Arnesano, M.
    Pietroni, F.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (08)
  • [5] Indoor air quality monitoring and source apportionment using low-cost sensors
    Higgins, Christina
    Kumar, Prashant
    Morawska, Lidia
    [J]. ENVIRONMENTAL RESEARCH COMMUNICATIONS, 2024, 6 (01):
  • [6] Development and Validation of Low-Cost Indoor Air Quality Monitoring System for Swine Buildings
    Arulmozhi, Elanchezhian
    Bhujel, Anil
    Deb, Nibas Chandra
    Tamrakar, Niraj
    Kang, Myeong Yong
    Kook, Junghoo
    Kang, Dae Yeong
    Seo, Eun Wan
    Kim, Hyeon Tae
    [J]. SENSORS, 2024, 24 (11)
  • [7] Electronic System for Real-Time Indoor Air Quality Monitoring
    Adochiei, Felix-Constantin
    Teodor-Nicolescu, Serban
    Adochiei, Ioana-Raluca
    Seritan, George-Calin
    Enache, Bogdan-Adrian
    Argatu, Florin-Ciprian
    Costin, Diana
    [J]. 2020 INTERNATIONAL CONFERENCE ON E-HEALTH AND BIOENGINEERING (EHB), 2020,
  • [8] HypeAIR: A novel framework for real-time low-cost sensor calibration for air quality monitoring in smart cities
    Bachechi, Chiara
    Rollo, Federica
    Po, Laura
    [J]. ECOLOGICAL INFORMATICS, 2024, 81
  • [9] Recent advancements in low-cost portable sensors for urban and indoor air quality monitoring
    Hernandez-Gordillo, A.
    Ruiz-Correa, S.
    Robledo-Valero, V.
    Hernandez-Rosales, C.
    Arriaga, S.
    [J]. AIR QUALITY ATMOSPHERE AND HEALTH, 2021, 14 (12): : 1931 - 1951
  • [10] On Autonomous Indoor Flights: High-Quality Real-Time Localization using Low-Cost Sensors
    Eckert, Juergen
    German, Reinhard
    Dressler, Falko
    [J]. 2012 IEEE INTERNATIONAL CONFERENCE ON COMMUNICATIONS (ICC), 2012,