In vivo bioluminescence tomography-guided system for pancreatic cancer radiotherapy research

被引:1
|
作者
Deng, Zijian [1 ,2 ,3 ]
Xu, Xiangkun [1 ,2 ]
Dehghani, Hamid [4 ]
Reyes, Juvenal [2 ]
Zheng, Lei [5 ]
Tran, Phuoc T. [6 ]
Wang, Ken Kang-Hsin [1 ,2 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Radiat Oncol, Biomed Imaging & Radiat Technol Lab, Dallas, TX 75390 USA
[2] Johns Hopkins Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Biomed Engn, Dallas, TX 75390 USA
[4] Univ Birmingham, Sch Comp Sci, Birmingham B15 2TT, England
[5] Johns Hopkins Sch Med, Sidney Kimmel Comprehens Canc Ctr, Dept Oncol, Baltimore, MD 21231 USA
[6] Univ Maryland, Sch Med, Dept Radiat Oncol, Baltimore, MD 21201 USA
来源
BIOMEDICAL OPTICS EXPRESS | 2024年 / 15卷 / 08期
关键词
RADIATION RESEARCH PLATFORM; FOCAL IRRADIATION; X-RAY; THERAPY; RECONSTRUCTION; RESOLUTION; LIGHT;
D O I
10.1364/BOE.523916
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Recent development of radiotherapy (RT) has heightened the use of radiation in managing pancreatic cancer. Thus, there is a need to investigate pancreatic cancer in a pre-clinical setting to advance our understanding of the role of RT. Widely-used cone-beam CT (CBCT) imaging cannot provide sufficient soft tissue contrast to guide irradiation. The pancreas is also prone to motion. Large collimation is unavoidably used for irradiation, costing normal tissue toxicity. We innovated a bioluminescence tomography (BLT)-guided system to address these needs. We established an orthotopic pancreatic ductal adenocarcinoma (PDAC) mouse model to access BLT. Mice underwent multi-projection and multi-spectral bioluminescence imaging (BLI), followed by CBCT imaging in an animal irradiator for BLT reconstruction and radiation planning. With optimized absorption coefficients, BLT localized PDAC at 1.25 +/- 0.19 mm accuracy. To account for BLT localization uncertainties, we expanded the BLT-reconstructed volume with margin to form planning target volume(PTVBLT) for radiation planning, covering 98.7 +/- 2.2% of PDAC. The BLT-guided conformal plan can cover 100% of tumors with limited normal tissue involvement across both inter-animal and inter-fraction cases, superior to the 2D BLI-guided conventional plan. BLT offers unique opportunities to localize PDAC for conformal irradiation, minimize normal tissue involvement, and support reproducibility in RT studies. (c) 2024 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement
引用
收藏
页码:4525 / 4539
页数:15
相关论文
共 50 条
  • [41] Multi-projection bioluminescence tomography guided system for small animal radiation research platform (SARRP)
    Zhang, Bin
    Iordachita, Iulian
    Wong, John W.
    Wang, Ken Kang-Hsin
    MULTIMODAL BIOMEDICAL IMAGING XI, 2016, 9701
  • [42] Assessment of the therapeutic accuracy of cone beam computed tomography-guided nasopharyngeal carcinoma radiotherapy
    Liu, Jiabin
    Lyman, Khumbula Maitireazvo
    Ding, Zhenhua
    Zhou, Liang
    ONCOLOGY LETTERS, 2019, 18 (02) : 1071 - 1080
  • [43] The clinical feasibility and effect of online cone beam computer tomography-guided intensity-modulated radiotherapy for nasopharyngeal cancer
    Wang, Jin
    Bai, Sen
    Chen, Nianyong
    Xu, Feng
    Jiang, Xiaoqin
    Li, Yan
    Xu, Qingfeng
    Shen, Yali
    Zhang, Hong
    Gong, Youling
    Zhong, Renming
    Jiang, Qingfeng
    RADIOTHERAPY AND ONCOLOGY, 2009, 90 (02) : 221 - 227
  • [44] Magnetic Resonance Imaging-Guided vs Computed Tomography-Guided Stereotactic Body Radiotherapy for Prostate Cancer The MIRAGE Randomized Clinical Trial
    Kishan, Amar U.
    Ma, Ting Martin
    Lamb, James M.
    Casado, Maria
    Wilhalme, Holly
    Low, Daniel A.
    Sheng, Ke
    Sharma, Sahil
    Nickols, Nicholas G.
    Pham, Jonathan
    Yang, Yingli
    Gao, Yu
    Neylon, John
    Basehart, Vincent
    Cao, Minsong
    Steinberg, Michael L.
    JAMA ONCOLOGY, 2023, 9 (03) : 365 - 373
  • [45] Computed tomography-guided permanent brachytherapy for locoregional recurrent gastric cancer
    Liangrong Shi
    Changping Wu
    Jun Wu
    Wenjie Zhou
    Mei Ji
    Hongyu Zhang
    Jiemin Zhao
    Yuanquan Huang
    Honglei Pei
    Zhong Li
    Jingfang Ju
    Jingting Jiang
    Radiation Oncology, 7
  • [46] Computed tomography-guided cryoablation for adrenal metastases secondary to lung cancer
    Zhang, Wen-Long
    Ruan, Dong-Li
    Sun, Li-Jun
    Wang, Tao
    Zhang, Wei
    Huang, Ya-Yong
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (05) : 1269 - 1274
  • [47] Computed tomography-guided percutaneous microwave ablation therapy for lung cancer
    Sun, Y. H.
    Song, P. Y.
    Guo, Y.
    Sheng, L. J.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (02) : 4858 - 4864
  • [48] Computed Tomography-Guided Percutaneous Radiofrequency Ablation of the Splanchnic Nerves as a Single Treatment for Pain Reduction in Patients with Pancreatic Cancer
    Grigoriadis, Stavros
    Tsitskari, Maria
    Ioannidi, Maria
    Zavridis, Periklis
    Kotsantis, Ioannis
    Kelekis, Alexis
    Filippiadis, Dimitrios
    DIAGNOSTICS, 2021, 11 (02)
  • [49] Magnetic resonance tomography-guided interventional procedure for diagnosis of prostate cancer
    Schernthaner, M.
    Helbich, T. H.
    Fueger, B. J.
    Margreiter, M.
    Memarsadeghi, M.
    Stiglbauer, A.
    Linhart, H. -G.
    Doan, A.
    Pinker, K.
    Brader, P.
    RADIOLOGE, 2011, 51 (11): : 962 - 968
  • [50] Computed tomography-guided permanent brachytherapy for locoregional recurrent gastric cancer
    Shi, Liangrong
    Wu, Changping
    Wu, Jun
    Zhou, Wenjie
    Ji, Mei
    Zhang, Hongyu
    Zhao, Jiemin
    Huang, Yuanquan
    Pei, Honglei
    Li, Zhong
    Ju, Jingfang
    Jiang, Jingting
    RADIATION ONCOLOGY, 2012, 7