摘要
Micro-acceleration generation during ultra-low-frequency micro-vibration calibration is a sensitive issue. There are issues of traditional pendulum tables being unable to change the pendulum radius and direction to produce micro-accelerations of different magnitudes, and the line shakers having a low signal-to-noise ratio when the vibration amplitude is the same as that of the pendulum tables. Therefore, a novel ultra-low-frequency micro-vibration calibration method is proposed to solve the above issues based on virtual pendulum motion trajectories of the Stewart platform. The micro-accelerations of 10-5 - 5 to 10-3 - 3 m/s2 2 can be generated by the trajectories with the radius of up to 12 m, the displacement amplitudes of up to 11.636 mm and the frequencies between 0.01 and 0.1 Hz. In the virtual pendulum motion, the maximum acceleration can be 2481 times greater than the acceleration of linear motion at the same frequency and displacement amplitude. In a comparison experiment with the current rotating platform, the maximum relative deviation of sensitivity amplitude calibration for pendulum motion around the x- and y-axis based on the Stewart platform are 0.411% and 0.295% respectively. The above results demonstrate the validity and reliability of this kind of method.
引用
收藏
页码:323 / 338
页数:16
相关论文
共 43 条
  • [31] Micro electromagnetic vibration energy harvester based on free/impact motion for low frequency-large amplitude operation
    Haroun, Ahmed
    Yamada, Ichiro
    Warisawa, Shin'ichi
    SENSORS AND ACTUATORS A-PHYSICAL, 2015, 224 : 87 - 98
  • [32] Image Motion Blur Mechanism-Based Measurement Method for Low-Frequency Vibration Amplitude and Direction
    Gong, Huinan
    Zhou, Zhenjie
    Pan, Jun
    Yang, Ming
    Ding, Hongquan
    Zhu, Xin
    Wu, Qingsong
    IEEE Sensors Journal, 2024, 24 (24) : 41301 - 41310
  • [33] Monocular Vision-Based Multiparameter Dynamic Calibration Method Used for the Low-Frequency Linear and Angular Vibration Sensors
    Yang, Ming
    Liu, Zhihua
    Wang, Ying
    Cai, Chenguang
    Yang, Jing
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (05) : 5365 - 5374
  • [34] A novel phase-based video motion magnification method for non-contact measurement of micro-amplitude vibration
    Yang, Yuanzhao
    Jiang, Qi
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2024, 215
  • [35] A fast vibration-level adjustment method for low-frequency vibration calibration based on modified filtered-x least mean square algorithm
    Li, Chao
    Chen, Zhangwei
    MEASUREMENT & CONTROL, 2020, 53 (3-4): : 328 - 338
  • [36] Monocular vision-based dynamic calibration method for determining the sensitivities of low-frequency tri-axial vibration sensors
    Liu, Wenfeng
    Cai, Chenguang
    Liu, Zhihua
    Yang, Ming
    Zuo, Shengnan
    Wang, Peicheng
    OPTICS EXPRESS, 2024, 32 (06) : 10130 - 10145
  • [37] Monocular vision-based low-frequency vibration calibration method with correction of the guideway bending in a long-stroke shaker
    Yang, Ming
    Wang, Ying
    Cai, Chenguang
    Liu, Zhihua
    Zhu, Haijiang
    Zhou, Shengyang
    OPTICS EXPRESS, 2019, 27 (11) : 15968 - 15981
  • [38] A novel high-power density, low-frequency electromagnetic vibration energy harvester based on anti-phase motion
    Foong, Faruq Muhammad
    Thein, Chung Ket
    Yurchenko, Daniil
    ENERGY CONVERSION AND MANAGEMENT, 2021, 238
  • [39] Prior information-based motion blur image restoration method for the low-frequency sinusoidal vibration measurements with machine vision
    Zuo, Shengnan
    Cai, Chenguang
    Yang, Ming
    Liu, Zhihua
    Wang, Deguang
    Wang, Ying
    SIGNAL PROCESSING, 2023, 212
  • [40] Monocular Vision-Based Calibration Method for the Axial and Transverse Sensitivities of Low-Frequency Triaxial Vibration Sensors With the Elliptical Orbit Excitation
    Yang, Ming
    Liu, Zhihua
    Cai, Chenguang
    Wang, Ying
    Yang, Jing
    Yang, Junjie
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (12) : 13763 - 13772